高效液相色谱法测定功能性食品中的氨基葡萄糖

Mai Huong Pham Thi, My Hanh Truong Thi, Huyen My Dang Thi, Trang Vu Thi, Khanh Cao Cong, Anh Hoang Quoc, Ngoc Anh Mai Thi, Minh Thu Nguyen Thi, Quang Huy Nguyen, Anh Huong Nguyen Thi
{"title":"高效液相色谱法测定功能性食品中的氨基葡萄糖","authors":"Mai Huong Pham Thi, My Hanh Truong Thi, Huyen My Dang Thi, Trang Vu Thi, Khanh Cao Cong, Anh Hoang Quoc, Ngoc Anh Mai Thi, Minh Thu Nguyen Thi, Quang Huy Nguyen, Anh Huong Nguyen Thi","doi":"10.47866/2615-9252/vjfc.3880","DOIUrl":null,"url":null,"abstract":"A simple, rapid and specific method using high performance liquid chromatography with fluorescence detector (HPLC-FLD) was developed for quantification of glucosamine in supplements after derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl). The chromatographic separation was achieved on a C18 column (150 mm × 4.6 mm × 5 µm) using a gradient mobile phase containing acetonitrile and water at a flow rate of 1.0 mL/min. The FLD detector was operated at excitation and emission wavelengths of 265 and 315 nm, respectively. The analytical method was validated for specificity, linearity, accuracy, and precision. The detector response for glucosamine was linear over the selected concentration range from 6.7 to 135 ppm with a correlation coefficient of 0.9988. The repeatability (RSD, n = 6) and reproducibility (RSD, n = 4) were from 2.54 to 3.23 % and from 2.24 to 3.07 %, respectively. The recovery was between 98.0 and 101.5 %. In addition, we also joined the interlaboratory proficiency testing program (code: H21.11) organized by the National Institute of Food Control with good result (z-score value was - 0.89 < 2). The method was successfully applied for the analysis of glucosamine in 15 supplement samples.","PeriodicalId":12896,"journal":{"name":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","volume":"45 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of glucosamine in functional food samples by high performance liquid chromatography (HPLC-FLD)\",\"authors\":\"Mai Huong Pham Thi, My Hanh Truong Thi, Huyen My Dang Thi, Trang Vu Thi, Khanh Cao Cong, Anh Hoang Quoc, Ngoc Anh Mai Thi, Minh Thu Nguyen Thi, Quang Huy Nguyen, Anh Huong Nguyen Thi\",\"doi\":\"10.47866/2615-9252/vjfc.3880\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, rapid and specific method using high performance liquid chromatography with fluorescence detector (HPLC-FLD) was developed for quantification of glucosamine in supplements after derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl). The chromatographic separation was achieved on a C18 column (150 mm × 4.6 mm × 5 µm) using a gradient mobile phase containing acetonitrile and water at a flow rate of 1.0 mL/min. The FLD detector was operated at excitation and emission wavelengths of 265 and 315 nm, respectively. The analytical method was validated for specificity, linearity, accuracy, and precision. The detector response for glucosamine was linear over the selected concentration range from 6.7 to 135 ppm with a correlation coefficient of 0.9988. The repeatability (RSD, n = 6) and reproducibility (RSD, n = 4) were from 2.54 to 3.23 % and from 2.24 to 3.07 %, respectively. The recovery was between 98.0 and 101.5 %. In addition, we also joined the interlaboratory proficiency testing program (code: H21.11) organized by the National Institute of Food Control with good result (z-score value was - 0.89 < 2). The method was successfully applied for the analysis of glucosamine in 15 supplement samples.\",\"PeriodicalId\":12896,\"journal\":{\"name\":\"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam\",\"volume\":\"45 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47866/2615-9252/vjfc.3880\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.3880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种高效液相色谱-荧光检测器(HPLC-FLD)定量9-氟酰氯甲酸甲酯(FMOC-Cl)衍生后营养补充品中氨基葡萄糖的方法。色谱分离采用C18色谱柱(150 mm × 4.6 mm × 5µm),梯度流动相含乙腈和水,流速为1.0 mL/min。FLD检测器的激发波长为265 nm,发射波长为315 nm。验证了分析方法的专属性、线性度、准确度和精密度。在6.7 ~ 135 ppm范围内,葡萄糖胺的检测响应呈线性关系,相关系数为0.9988。重复性(RSD, n = 6)和重现性(RSD, n = 4)分别为2.54 ~ 3.23%和2.24 ~ 3.07%。回收率在98.0% ~ 101.5%之间。此外,我们还参加了国家食品控制研究所组织的实验室间能力测试项目(代码:H21.11),结果良好(z-score值为- 0.89 < 2)。该方法成功应用于15份补充剂样品的葡萄糖胺分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of glucosamine in functional food samples by high performance liquid chromatography (HPLC-FLD)
A simple, rapid and specific method using high performance liquid chromatography with fluorescence detector (HPLC-FLD) was developed for quantification of glucosamine in supplements after derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl). The chromatographic separation was achieved on a C18 column (150 mm × 4.6 mm × 5 µm) using a gradient mobile phase containing acetonitrile and water at a flow rate of 1.0 mL/min. The FLD detector was operated at excitation and emission wavelengths of 265 and 315 nm, respectively. The analytical method was validated for specificity, linearity, accuracy, and precision. The detector response for glucosamine was linear over the selected concentration range from 6.7 to 135 ppm with a correlation coefficient of 0.9988. The repeatability (RSD, n = 6) and reproducibility (RSD, n = 4) were from 2.54 to 3.23 % and from 2.24 to 3.07 %, respectively. The recovery was between 98.0 and 101.5 %. In addition, we also joined the interlaboratory proficiency testing program (code: H21.11) organized by the National Institute of Food Control with good result (z-score value was - 0.89 < 2). The method was successfully applied for the analysis of glucosamine in 15 supplement samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Producing positive control materials for template in PCR testing to detect botulinum neurotoxin types A and B genes Food safety knowledge and practices of vegetarian food processors in Hanoi in 2022-2023 Research and development of non-enzymatic electrochemical sensors utilizing porous ZnO/graphene electrodes to determine xanthine Study on coffee husk treatment by microorganisms A comprehensive study on reference material of Imidacloprid in tomato matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1