直肠癌放疗联合疗程的优化

A. Grigorieva, A. Bulavskaya, T. A. Nguyen, S. Stuchebrov, Z. Startseva, V. Velikaya, N. Turgunova, I. Miloichikova
{"title":"直肠癌放疗联合疗程的优化","authors":"A. Grigorieva, A. Bulavskaya, T. A. Nguyen, S. Stuchebrov, Z. Startseva, V. Velikaya, N. Turgunova, I. Miloichikova","doi":"10.21870/0131-3878-2022-31-2-128-136","DOIUrl":null,"url":null,"abstract":"Due to the new rapidly developed technological equipment for radiotherapy available in cancer clinics, the study of the optimal combination of topometric preparation of a patient with planning and the delivery of treatment in order to achieve the main goal of radiation therapy – maximum exposure of the foci with minimal damage to healthy tissue. The reduction of dose to critical or-gans and healthy tissues in general is an important and urgent task. The purpose of the paper is to explore the possibility of optimization of the combined radiation therapy in patients with rectal cancer, with account of advanced approaches to topometric preparation of a patient and dosime-try planning. Six patients 47-59 years of age, with the stage III of the lower ampullary rectal can-cer, received two-phase pre-operative combined radiotherapy at the Tomsk Cancer Research In-stitute NMRC. The Phase 1 – distant radiation therapy delivery in standard mode with a single fo-cal dose (ROD) of 2 Gy, 5 times a week, totally 20 fractions, to focal dose (SOD) of 40 Gy. The Phase 2 – intracavitary radiation therapy, ROD – 3 Gy, SOD – 15 Gy, locally in the tumor area, 2 times a week, total number – 5 fractions. The conventional radiation therapy planning was carried out with the use of the XiO 3-D dosimetry planning system for the \"Theratron Equinox 80\" (radia-tion of the isotope Co-60, Egamma=1.25 MeV), gamma-therapeutic apparatus, and for the SL75-5-MT (Electron braking radiation, E=6 MeV) linear accelerator. For conformal radial therapy the plan-ning system for linear accelerator «Elekta Synergy» (electron brake radiation, E=6 MeV) is used. For intracavitary radiotherapy the dosimetry planning system HDRPlus for the apparatus \"Multi-Source\" (radiation of isotope Co-60, Egamma=1.25 MeV) is used. Radiation doses to critical organs of pa-tients with lower ampullary rectal cancer exposed to combined course of radiotherapy was calculated. It has been shown that the use of advanced techniques for pretreatment topometric preparation of a patient and dosimetry planning makes possible optimization of combined radiotherapy with account of radiation doses to critical organs.","PeriodicalId":6315,"journal":{"name":"\"Radiation and Risk\" Bulletin of the National Radiation and Epidemiological Registry","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Optimization of radiotherapy combined course for rectal cancer\",\"authors\":\"A. Grigorieva, A. Bulavskaya, T. A. Nguyen, S. Stuchebrov, Z. Startseva, V. Velikaya, N. Turgunova, I. Miloichikova\",\"doi\":\"10.21870/0131-3878-2022-31-2-128-136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the new rapidly developed technological equipment for radiotherapy available in cancer clinics, the study of the optimal combination of topometric preparation of a patient with planning and the delivery of treatment in order to achieve the main goal of radiation therapy – maximum exposure of the foci with minimal damage to healthy tissue. The reduction of dose to critical or-gans and healthy tissues in general is an important and urgent task. The purpose of the paper is to explore the possibility of optimization of the combined radiation therapy in patients with rectal cancer, with account of advanced approaches to topometric preparation of a patient and dosime-try planning. Six patients 47-59 years of age, with the stage III of the lower ampullary rectal can-cer, received two-phase pre-operative combined radiotherapy at the Tomsk Cancer Research In-stitute NMRC. The Phase 1 – distant radiation therapy delivery in standard mode with a single fo-cal dose (ROD) of 2 Gy, 5 times a week, totally 20 fractions, to focal dose (SOD) of 40 Gy. The Phase 2 – intracavitary radiation therapy, ROD – 3 Gy, SOD – 15 Gy, locally in the tumor area, 2 times a week, total number – 5 fractions. The conventional radiation therapy planning was carried out with the use of the XiO 3-D dosimetry planning system for the \\\"Theratron Equinox 80\\\" (radia-tion of the isotope Co-60, Egamma=1.25 MeV), gamma-therapeutic apparatus, and for the SL75-5-MT (Electron braking radiation, E=6 MeV) linear accelerator. For conformal radial therapy the plan-ning system for linear accelerator «Elekta Synergy» (electron brake radiation, E=6 MeV) is used. For intracavitary radiotherapy the dosimetry planning system HDRPlus for the apparatus \\\"Multi-Source\\\" (radiation of isotope Co-60, Egamma=1.25 MeV) is used. Radiation doses to critical organs of pa-tients with lower ampullary rectal cancer exposed to combined course of radiotherapy was calculated. It has been shown that the use of advanced techniques for pretreatment topometric preparation of a patient and dosimetry planning makes possible optimization of combined radiotherapy with account of radiation doses to critical organs.\",\"PeriodicalId\":6315,\"journal\":{\"name\":\"\\\"Radiation and Risk\\\" Bulletin of the National Radiation and Epidemiological Registry\",\"volume\":\"26 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\\\"Radiation and Risk\\\" Bulletin of the National Radiation and Epidemiological Registry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21870/0131-3878-2022-31-2-128-136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"\"Radiation and Risk\" Bulletin of the National Radiation and Epidemiological Registry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21870/0131-3878-2022-31-2-128-136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于癌症诊所放射治疗的新技术设备的快速发展,为了实现放射治疗的主要目标-最大限度地暴露病灶,对健康组织的损害最小,研究患者的地形测量准备与计划和治疗交付的最佳组合。总的来说,减少对关键器官和健康组织的剂量是一项重要而紧迫的任务。本文的目的是探讨优化直肠癌患者联合放射治疗的可能性,考虑到患者的地形测量准备和剂量计划的先进方法。6例47-59岁的下壶腹直肠癌III期患者在托木斯克癌症研究所NMRC接受了两期术前联合放疗。第一阶段-远距离放射治疗以标准模式递送,单局剂量(ROD)为2gy,每周5次,共20次,至局剂量(SOD)为40gy。2期腔内放疗,ROD - 3gy, SOD - 15gy,局部肿瘤区放疗,每周2次,总次数- 5次。使用XiO三维剂量计系统对“Theratron Equinox 80”(同位素Co-60辐射,Egamma=1.25 MeV)、伽玛治疗仪和SL75-5-MT(电子制动辐射,E=6 MeV)直线加速器进行常规放射治疗计划。对于适形放射治疗,使用线性加速器«Elekta Synergy»(电子制动辐射,E=6 MeV)的规划系统。腔内放疗使用“多源”(同位素Co-60辐射,Egamma=1.25 MeV)仪器的剂量计规划系统HDRPlus。计算下壶腹直肠癌患者在联合放疗过程中对关键器官的辐射剂量。研究表明,使用先进的技术对患者进行预处理,地形测量准备和剂量计计划,可以优化联合放疗,并考虑对关键器官的辐射剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of radiotherapy combined course for rectal cancer
Due to the new rapidly developed technological equipment for radiotherapy available in cancer clinics, the study of the optimal combination of topometric preparation of a patient with planning and the delivery of treatment in order to achieve the main goal of radiation therapy – maximum exposure of the foci with minimal damage to healthy tissue. The reduction of dose to critical or-gans and healthy tissues in general is an important and urgent task. The purpose of the paper is to explore the possibility of optimization of the combined radiation therapy in patients with rectal cancer, with account of advanced approaches to topometric preparation of a patient and dosime-try planning. Six patients 47-59 years of age, with the stage III of the lower ampullary rectal can-cer, received two-phase pre-operative combined radiotherapy at the Tomsk Cancer Research In-stitute NMRC. The Phase 1 – distant radiation therapy delivery in standard mode with a single fo-cal dose (ROD) of 2 Gy, 5 times a week, totally 20 fractions, to focal dose (SOD) of 40 Gy. The Phase 2 – intracavitary radiation therapy, ROD – 3 Gy, SOD – 15 Gy, locally in the tumor area, 2 times a week, total number – 5 fractions. The conventional radiation therapy planning was carried out with the use of the XiO 3-D dosimetry planning system for the "Theratron Equinox 80" (radia-tion of the isotope Co-60, Egamma=1.25 MeV), gamma-therapeutic apparatus, and for the SL75-5-MT (Electron braking radiation, E=6 MeV) linear accelerator. For conformal radial therapy the plan-ning system for linear accelerator «Elekta Synergy» (electron brake radiation, E=6 MeV) is used. For intracavitary radiotherapy the dosimetry planning system HDRPlus for the apparatus "Multi-Source" (radiation of isotope Co-60, Egamma=1.25 MeV) is used. Radiation doses to critical organs of pa-tients with lower ampullary rectal cancer exposed to combined course of radiotherapy was calculated. It has been shown that the use of advanced techniques for pretreatment topometric preparation of a patient and dosimetry planning makes possible optimization of combined radiotherapy with account of radiation doses to critical organs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pilot-demonstration energy complex (PDEC): the level of radiological protection of the population due to the modern “dose-effect” model of the ICRP Distribution of the ambient dose equivalent rate of gamma radiation in specially protected natural areas of the Rostov region Application of unified methodology for analytical calculation of absorbed dose gamma-radiation fractions to cylinder-shape biological objects Assessments of uncertainties in effective radiation doses to the population in the contaminated regions of the Russian Federation after the Chernobyl nuclear power plant accident Evaluation of the operational intervention levels for radiation protection of the public based on the emergency scenarios at Russian nuclear power plants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1