A. Volkov, O. I. Rytenkova, E. V. Tsurkan, T. A. Babarykina, G. S. Surzhikova
{"title":"有无胎儿染色体异常的孕妇血清生化参数","authors":"A. Volkov, O. I. Rytenkova, E. V. Tsurkan, T. A. Babarykina, G. S. Surzhikova","doi":"10.23946/2500-0764-2022-7-4-91-99","DOIUrl":null,"url":null,"abstract":"Aim. To analyse the levels of serum beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein A (PAPP-A) in pregnant women without fetal chromosomal abnormalities and with fetal trisomy 21 (Down syndrome) or 18 (Edwards syndrome).Materials and Methods. We performed a retrospective analysis of serum biochemical parameters of 1214 women who had previously undergone karyotyping as a part of prenatal or postnatal screening. Patients were stratified into those with a normal fetal karyotype, those carrying a fetus with trisomy 21, and those carrying a fetus with trisomy 18. Levels of serum β-hCG and PAPP-A were estimated using the AutoDELFIA automatic immunoassay system.Results. In most of the women carrying a fetus with trisomy 21, serum β-hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b -hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b-hCG and PAPP-A are sensitive markers of fetal trisomy 21 and trisomy 18 in pregnant women.","PeriodicalId":12493,"journal":{"name":"Fundamental and Clinical Medicine","volume":"127 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Serum biochemical parameters in pregnant women with and without fetal chromosomal abnornalities\",\"authors\":\"A. Volkov, O. I. Rytenkova, E. V. Tsurkan, T. A. Babarykina, G. S. Surzhikova\",\"doi\":\"10.23946/2500-0764-2022-7-4-91-99\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim. To analyse the levels of serum beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein A (PAPP-A) in pregnant women without fetal chromosomal abnormalities and with fetal trisomy 21 (Down syndrome) or 18 (Edwards syndrome).Materials and Methods. We performed a retrospective analysis of serum biochemical parameters of 1214 women who had previously undergone karyotyping as a part of prenatal or postnatal screening. Patients were stratified into those with a normal fetal karyotype, those carrying a fetus with trisomy 21, and those carrying a fetus with trisomy 18. Levels of serum β-hCG and PAPP-A were estimated using the AutoDELFIA automatic immunoassay system.Results. In most of the women carrying a fetus with trisomy 21, serum β-hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b -hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b-hCG and PAPP-A are sensitive markers of fetal trisomy 21 and trisomy 18 in pregnant women.\",\"PeriodicalId\":12493,\"journal\":{\"name\":\"Fundamental and Clinical Medicine\",\"volume\":\"127 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fundamental and Clinical Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23946/2500-0764-2022-7-4-91-99\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fundamental and Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23946/2500-0764-2022-7-4-91-99","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Serum biochemical parameters in pregnant women with and without fetal chromosomal abnornalities
Aim. To analyse the levels of serum beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein A (PAPP-A) in pregnant women without fetal chromosomal abnormalities and with fetal trisomy 21 (Down syndrome) or 18 (Edwards syndrome).Materials and Methods. We performed a retrospective analysis of serum biochemical parameters of 1214 women who had previously undergone karyotyping as a part of prenatal or postnatal screening. Patients were stratified into those with a normal fetal karyotype, those carrying a fetus with trisomy 21, and those carrying a fetus with trisomy 18. Levels of serum β-hCG and PAPP-A were estimated using the AutoDELFIA automatic immunoassay system.Results. In most of the women carrying a fetus with trisomy 21, serum β-hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b -hCG has been increased as compared to the reference range. In contrast, women carrying a fetus with trisomy 18 generally had reduced serum β-hCG. In both cases, the level of serum PAPP-A has been decreased in comparison with a reference range. The proportion of women with a 2-fold reduced serum PAPP-A was 52.4% and 88.6% if carrying fetuses with trisomy 21 and trisomy 18, respectively.Conclusion. Serum b-hCG and PAPP-A are sensitive markers of fetal trisomy 21 and trisomy 18 in pregnant women.