A. A. Al Hayek, Asirvatham Alwin Robert, Abdulghani H. Al Saeed, M. A. Al Dawish
{"title":"应用瞬时血糖监测系统评价300 U/mL与100 U/mL甘精胰岛素对1型糖尿病患者的满意度及临床疗效","authors":"A. A. Al Hayek, Asirvatham Alwin Robert, Abdulghani H. Al Saeed, M. A. Al Dawish","doi":"10.1177/11795514221098415","DOIUrl":null,"url":null,"abstract":"Background and Aims: To analyze patient-reported satisfaction and clinical effectiveness of concentrated insulin glargine 300 U/mL (Gla-300) among patients with type 1 diabetes (T1D) using a flash glucose monitoring (FGM) system. Methods: This comparative study was conducted among 86 patients with T1D (aged 14-40 years), who were treated with Glargine 100 U/mL (Gla-100) and switched to Gla-300 at day 1 (baseline). The following data were collected from each patient: demographic information, clinical parameters, and glycemic control markers. All patients completed the Diabetes Treatment Satisfaction Questionnaire (Arabic version), first at baseline and then after 12 weeks. A comparison was done for all the data recorded at baseline (on Gla-100) and after 12 weeks (on Gla-300) and subjected to analysis. Results: Compared to patients treated with Gla-100, significant improvements were observed in the Gla-300 group, in terms of the ambulatory glucose profile (AGP) markers, such as percentage of time spent within the target range of the glucose levels (70-180 mg/dL) (P = .037), percentage which fell below the target (<70 mg/dL) (P = .027), and percentage of time spent (<54 mg/dL) (P = .043). Compared to Gla-100, patients treated with Gla-300 experienced significant improvements in the current treatment satisfactions (P = .047), convenient finding treatment recently (P = .034), and flexible finding treatment recently (P = .041), recommend the current treatment (P = .042) and satisfied to continue the current treatment (P = .035). Conclusion: Compared to the patients on Gla-100, patients treated with Gla-300 exhibited significant improvements in the AGP markers and degree of treatment satisfaction.","PeriodicalId":44715,"journal":{"name":"Clinical Medicine Insights-Endocrinology and Diabetes","volume":"193 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Patient Reported Satisfaction and Clinical Efficacy of Insulin Glargine 300 U/mL Versus 100 U/mL in Patients With Type 1 Diabetes Using Flash Glucose Monitoring System\",\"authors\":\"A. A. Al Hayek, Asirvatham Alwin Robert, Abdulghani H. Al Saeed, M. A. Al Dawish\",\"doi\":\"10.1177/11795514221098415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and Aims: To analyze patient-reported satisfaction and clinical effectiveness of concentrated insulin glargine 300 U/mL (Gla-300) among patients with type 1 diabetes (T1D) using a flash glucose monitoring (FGM) system. Methods: This comparative study was conducted among 86 patients with T1D (aged 14-40 years), who were treated with Glargine 100 U/mL (Gla-100) and switched to Gla-300 at day 1 (baseline). The following data were collected from each patient: demographic information, clinical parameters, and glycemic control markers. All patients completed the Diabetes Treatment Satisfaction Questionnaire (Arabic version), first at baseline and then after 12 weeks. A comparison was done for all the data recorded at baseline (on Gla-100) and after 12 weeks (on Gla-300) and subjected to analysis. Results: Compared to patients treated with Gla-100, significant improvements were observed in the Gla-300 group, in terms of the ambulatory glucose profile (AGP) markers, such as percentage of time spent within the target range of the glucose levels (70-180 mg/dL) (P = .037), percentage which fell below the target (<70 mg/dL) (P = .027), and percentage of time spent (<54 mg/dL) (P = .043). Compared to Gla-100, patients treated with Gla-300 experienced significant improvements in the current treatment satisfactions (P = .047), convenient finding treatment recently (P = .034), and flexible finding treatment recently (P = .041), recommend the current treatment (P = .042) and satisfied to continue the current treatment (P = .035). Conclusion: Compared to the patients on Gla-100, patients treated with Gla-300 exhibited significant improvements in the AGP markers and degree of treatment satisfaction.\",\"PeriodicalId\":44715,\"journal\":{\"name\":\"Clinical Medicine Insights-Endocrinology and Diabetes\",\"volume\":\"193 1\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Medicine Insights-Endocrinology and Diabetes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/11795514221098415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Medicine Insights-Endocrinology and Diabetes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/11795514221098415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Evaluation of Patient Reported Satisfaction and Clinical Efficacy of Insulin Glargine 300 U/mL Versus 100 U/mL in Patients With Type 1 Diabetes Using Flash Glucose Monitoring System
Background and Aims: To analyze patient-reported satisfaction and clinical effectiveness of concentrated insulin glargine 300 U/mL (Gla-300) among patients with type 1 diabetes (T1D) using a flash glucose monitoring (FGM) system. Methods: This comparative study was conducted among 86 patients with T1D (aged 14-40 years), who were treated with Glargine 100 U/mL (Gla-100) and switched to Gla-300 at day 1 (baseline). The following data were collected from each patient: demographic information, clinical parameters, and glycemic control markers. All patients completed the Diabetes Treatment Satisfaction Questionnaire (Arabic version), first at baseline and then after 12 weeks. A comparison was done for all the data recorded at baseline (on Gla-100) and after 12 weeks (on Gla-300) and subjected to analysis. Results: Compared to patients treated with Gla-100, significant improvements were observed in the Gla-300 group, in terms of the ambulatory glucose profile (AGP) markers, such as percentage of time spent within the target range of the glucose levels (70-180 mg/dL) (P = .037), percentage which fell below the target (<70 mg/dL) (P = .027), and percentage of time spent (<54 mg/dL) (P = .043). Compared to Gla-100, patients treated with Gla-300 experienced significant improvements in the current treatment satisfactions (P = .047), convenient finding treatment recently (P = .034), and flexible finding treatment recently (P = .041), recommend the current treatment (P = .042) and satisfied to continue the current treatment (P = .035). Conclusion: Compared to the patients on Gla-100, patients treated with Gla-300 exhibited significant improvements in the AGP markers and degree of treatment satisfaction.