{"title":"基于光伏的混合动力系统性能分析与节能","authors":"S. K. Rajput, D. K. Dheer","doi":"10.13052/dgaej2156-3306.3814","DOIUrl":null,"url":null,"abstract":"The increase in energy consumption due to population expansion and scarcity of fossil fuels is happening simultaneously in developing countries like India. In this regard, commercial buildings are increasingly required to employ renewable energy sources (like PV) and conserve the energy for improving energy efficiency. This research article examines the performance of such PV-based hybrid power system, consists of 11 kV grid supply, 100 kWp PV plant & 200 kVA diesel generator. The results indicate that the addition of 68.34 kVAr shunt capacitor bank to Automatic Power Factor Compensation (APFC) panel, keeps the Power Factor (PF) unity and also eliminates the PF penalties in electricity bills. The maximum demand (MD) saving Rs 54528.00 (INR) on annual basis is achieved after the integration of PV with low voltage (433 V) distribution system and grid supply (11 kV). This integration has also reduced the average transformer loading to 64.73% and improved the transformer life. However the development of high current harmonics (average value 47.10%) must be reduced to ensure the life of the electrical load.","PeriodicalId":11205,"journal":{"name":"Distributed Generation & Alternative Energy Journal","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Analysis and Energy Conservation of PV Based Hybrid Power System\",\"authors\":\"S. K. Rajput, D. K. Dheer\",\"doi\":\"10.13052/dgaej2156-3306.3814\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The increase in energy consumption due to population expansion and scarcity of fossil fuels is happening simultaneously in developing countries like India. In this regard, commercial buildings are increasingly required to employ renewable energy sources (like PV) and conserve the energy for improving energy efficiency. This research article examines the performance of such PV-based hybrid power system, consists of 11 kV grid supply, 100 kWp PV plant & 200 kVA diesel generator. The results indicate that the addition of 68.34 kVAr shunt capacitor bank to Automatic Power Factor Compensation (APFC) panel, keeps the Power Factor (PF) unity and also eliminates the PF penalties in electricity bills. The maximum demand (MD) saving Rs 54528.00 (INR) on annual basis is achieved after the integration of PV with low voltage (433 V) distribution system and grid supply (11 kV). This integration has also reduced the average transformer loading to 64.73% and improved the transformer life. However the development of high current harmonics (average value 47.10%) must be reduced to ensure the life of the electrical load.\",\"PeriodicalId\":11205,\"journal\":{\"name\":\"Distributed Generation & Alternative Energy Journal\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Distributed Generation & Alternative Energy Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13052/dgaej2156-3306.3814\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Distributed Generation & Alternative Energy Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13052/dgaej2156-3306.3814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在印度等发展中国家,由于人口扩张和化石燃料短缺而导致的能源消耗增加正在同时发生。在这方面,商业楼宇越来越需要采用可再生能源(如光伏)和节约能源,以提高能源效率。本文研究了由11kv电网供电、100kwp光伏电站和200kva柴油发电机组成的基于光伏的混合电力系统的性能。结果表明,在功率因数自动补偿(APFC)面板上增加68.34 kVAr并联电容器组,既保持了功率因数(PF)的统一,又消除了电费中的PF罚款。在光伏与低压(433伏)配电系统和电网供应(11千伏)集成后,每年最大需求(MD)节省54528.00卢比(印度卢比)。这种集成还将变压器的平均负载降低到64.73%,并提高了变压器的寿命。然而,必须减少大电流谐波的发展(平均值47.10%),以确保电气负载的寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance Analysis and Energy Conservation of PV Based Hybrid Power System
The increase in energy consumption due to population expansion and scarcity of fossil fuels is happening simultaneously in developing countries like India. In this regard, commercial buildings are increasingly required to employ renewable energy sources (like PV) and conserve the energy for improving energy efficiency. This research article examines the performance of such PV-based hybrid power system, consists of 11 kV grid supply, 100 kWp PV plant & 200 kVA diesel generator. The results indicate that the addition of 68.34 kVAr shunt capacitor bank to Automatic Power Factor Compensation (APFC) panel, keeps the Power Factor (PF) unity and also eliminates the PF penalties in electricity bills. The maximum demand (MD) saving Rs 54528.00 (INR) on annual basis is achieved after the integration of PV with low voltage (433 V) distribution system and grid supply (11 kV). This integration has also reduced the average transformer loading to 64.73% and improved the transformer life. However the development of high current harmonics (average value 47.10%) must be reduced to ensure the life of the electrical load.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Power Grid User Behavior Based on Data Mining Algorithms – System Design and Implementation Load Frequency Control Strategy of Interconnected Power System Based on Tube DMPC KWH Cost Analysis of Energy Storage Power Station Based on Changing Trend of Battery Cost Study on PV Power Prediction Based on VMD-IGWO-LSTM Research on Environmental Performance and Measurement of Smart City Power Supply Based on Non Radial Network DEA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1