Raed M.Shaban, H. J. Shaymaa, W. A. Radhi, Ziyad T. Almalki, A. MuzahimM.
{"title":"研究低密度聚乙烯中添加羧甲基纤维素粉对x射线屏蔽辐射的影响","authors":"Raed M.Shaban, H. J. Shaymaa, W. A. Radhi, Ziyad T. Almalki, A. MuzahimM.","doi":"10.31257/2018/jkp/100215","DOIUrl":null,"url":null,"abstract":"Carboxy methyl cellulose Low Density Polyethylene Shielding radiation The attenuation measurements of x-ray of voltage range (21kv) for hosted polymer material were done using x-ray unit, in order to extract the effect of adding carboxy methyl cellulose material (CMC) to low density polyethylene on x-ray radiation attenuation . The linear attenuation coefficient (µ l ) was calculated for the voltage range mentioned above , through linear equations of the yield of graphic representation between the logarithmic absorption and the sample thickness X(cm). The mass attenuation coefficient (µ m ) could also be calculated through the graphic relation between the logarithmic absorption and the equivalent thickness of the sample X m (gm/cm 2 ) such that slope of the graphic relation represents linear the attenuation coefficient or mass attenuation coefficient. The calculated results indicated that the efficiency of","PeriodicalId":16215,"journal":{"name":"Journal of Kufa - Physics","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study the Effect of adding Carboxy Methyl Cellulose Powder to Low Density Polyethylene on Shielding Radiation for the X-ray\",\"authors\":\"Raed M.Shaban, H. J. Shaymaa, W. A. Radhi, Ziyad T. Almalki, A. MuzahimM.\",\"doi\":\"10.31257/2018/jkp/100215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Carboxy methyl cellulose Low Density Polyethylene Shielding radiation The attenuation measurements of x-ray of voltage range (21kv) for hosted polymer material were done using x-ray unit, in order to extract the effect of adding carboxy methyl cellulose material (CMC) to low density polyethylene on x-ray radiation attenuation . The linear attenuation coefficient (µ l ) was calculated for the voltage range mentioned above , through linear equations of the yield of graphic representation between the logarithmic absorption and the sample thickness X(cm). The mass attenuation coefficient (µ m ) could also be calculated through the graphic relation between the logarithmic absorption and the equivalent thickness of the sample X m (gm/cm 2 ) such that slope of the graphic relation represents linear the attenuation coefficient or mass attenuation coefficient. The calculated results indicated that the efficiency of\",\"PeriodicalId\":16215,\"journal\":{\"name\":\"Journal of Kufa - Physics\",\"volume\":\"28 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Kufa - Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31257/2018/jkp/100215\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Kufa - Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31257/2018/jkp/100215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
为了提取羧甲基纤维素(CMC)在低密度聚乙烯中添加对x射线辐射衰减的影响,利用x射线单元对负载聚合物材料在电压范围(21kv)下的x射线衰减进行了测量。通过对数吸收与样品厚度X(cm)之间的图形表示产率的线性方程,计算上述电压范围内的线性衰减系数(µl)。也可以通过对数吸收与样品等效厚度X m (gm/ cm2)的图形关系来计算质量衰减系数(µm),图形关系的斜率表示衰减系数或质量衰减系数的线性关系。计算结果表明
Study the Effect of adding Carboxy Methyl Cellulose Powder to Low Density Polyethylene on Shielding Radiation for the X-ray
Carboxy methyl cellulose Low Density Polyethylene Shielding radiation The attenuation measurements of x-ray of voltage range (21kv) for hosted polymer material were done using x-ray unit, in order to extract the effect of adding carboxy methyl cellulose material (CMC) to low density polyethylene on x-ray radiation attenuation . The linear attenuation coefficient (µ l ) was calculated for the voltage range mentioned above , through linear equations of the yield of graphic representation between the logarithmic absorption and the sample thickness X(cm). The mass attenuation coefficient (µ m ) could also be calculated through the graphic relation between the logarithmic absorption and the equivalent thickness of the sample X m (gm/cm 2 ) such that slope of the graphic relation represents linear the attenuation coefficient or mass attenuation coefficient. The calculated results indicated that the efficiency of