牙种植体稳定性评价:锥形种植体与圆柱形种植体的比较研究

Doaa Alghafour, Eatemad A. Shoreibah, M. Attia
{"title":"牙种植体稳定性评价:锥形种植体与圆柱形种植体的比较研究","authors":"Doaa Alghafour, Eatemad A. Shoreibah, M. Attia","doi":"10.21608/adjg.2021.46699.1305","DOIUrl":null,"url":null,"abstract":"Purpose: This study was carried out to evaluate stability of tapered and cylindrical implants in partially edentulous patients. Materials and Methods: The current study was done on 14 implants that were alienated randomly into two groups: Group I: treated with tapered implant, Group II: treated with cylindrical implant. Results: Clinical results: Modified Gingival Index (MGI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.254 at 3 months, p=0.606 at 6 months). Modified Plaque Index (MPI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.298). Probing Depth(PD) revealed a nonsignificant statistically difference on comparing results of 3 months and 6 months postoperatively (p=1 at 3 months, p=0.591 at 6 months). Stability: the mean value increased by time from baseline to after 6 months in Group I (61.57±6.4 to 71.57±6.08), however, the mean value increased from 63.14±7.17 to 74.57±5.53 in Group II. Implant stability revealed nonsignificant statistically differences for p-values (P 0.05). Radiographic results: Bone Density (BD):The statistical analysis between the two groups in the mean percent change in bone density revealed a non-significant statistically difference between the 6 months results. It was 1.88±1.37% for the first group and 11.54±15.63% for the second group (p=0.20).Conclusions: Conical and cylindrical implants have comparable biological effects during the healing process. The properties of the bone site can influence the stability of the implant. Codex : 14/21.10 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.46699.1305 Oral Medicine & Surgical Sciences (Oral Medicine, Oral & Maxillofacial Surgery, Oral Pathology, Oral Biology)","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"35 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Dental Implant Stability: A comparative Study of Tapered vs Cylindrical Implants\",\"authors\":\"Doaa Alghafour, Eatemad A. Shoreibah, M. Attia\",\"doi\":\"10.21608/adjg.2021.46699.1305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: This study was carried out to evaluate stability of tapered and cylindrical implants in partially edentulous patients. Materials and Methods: The current study was done on 14 implants that were alienated randomly into two groups: Group I: treated with tapered implant, Group II: treated with cylindrical implant. Results: Clinical results: Modified Gingival Index (MGI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.254 at 3 months, p=0.606 at 6 months). Modified Plaque Index (MPI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.298). Probing Depth(PD) revealed a nonsignificant statistically difference on comparing results of 3 months and 6 months postoperatively (p=1 at 3 months, p=0.591 at 6 months). Stability: the mean value increased by time from baseline to after 6 months in Group I (61.57±6.4 to 71.57±6.08), however, the mean value increased from 63.14±7.17 to 74.57±5.53 in Group II. Implant stability revealed nonsignificant statistically differences for p-values (P 0.05). Radiographic results: Bone Density (BD):The statistical analysis between the two groups in the mean percent change in bone density revealed a non-significant statistically difference between the 6 months results. It was 1.88±1.37% for the first group and 11.54±15.63% for the second group (p=0.20).Conclusions: Conical and cylindrical implants have comparable biological effects during the healing process. The properties of the bone site can influence the stability of the implant. Codex : 14/21.10 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.46699.1305 Oral Medicine & Surgical Sciences (Oral Medicine, Oral & Maxillofacial Surgery, Oral Pathology, Oral Biology)\",\"PeriodicalId\":7493,\"journal\":{\"name\":\"Al-Azhar Dental Journal for Girls\",\"volume\":\"35 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al-Azhar Dental Journal for Girls\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/adjg.2021.46699.1305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2021.46699.1305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究评估锥形种植体和圆柱形种植体在部分无牙患者中的稳定性。材料与方法:本研究将14例种植体随机分离为两组:I组:锥形种植体处理,II组:圆柱形种植体处理。结果:临床结果:改良牙龈指数(MGI)与术后3个月与6个月比较,差异无统计学意义(3个月时p=0.254, 6个月时p=0.606)。改良斑块指数(MPI)与术后3个月和6个月比较,差异无统计学意义(p=0.298)。探查深度(PD)与术后3个月和6个月比较,差异无统计学意义(3个月时p=1, 6个月时p=0.591)。稳定性:从基线到6个月后,I组的平均值随时间增加(61.57±6.4至71.57±6.08),II组的平均值从63.14±7.17增加至74.57±5.53。种植体稳定性P值差异无统计学意义(P 0.05)。骨密度(BD):两组间骨密度平均变化百分比的统计分析显示6个月间结果无统计学差异。第一组为1.88±1.37%,第二组为11.54±15.63% (p=0.20)。结论:锥形种植体和圆柱形种植体在愈合过程中具有相当的生物学效果。骨位置的特性会影响种植体的稳定性。法典:14/21.10 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.46699.1305口腔医学与外科科学(口腔医学,口腔颌面外科,口腔病理学,口腔生物学)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Dental Implant Stability: A comparative Study of Tapered vs Cylindrical Implants
Purpose: This study was carried out to evaluate stability of tapered and cylindrical implants in partially edentulous patients. Materials and Methods: The current study was done on 14 implants that were alienated randomly into two groups: Group I: treated with tapered implant, Group II: treated with cylindrical implant. Results: Clinical results: Modified Gingival Index (MGI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.254 at 3 months, p=0.606 at 6 months). Modified Plaque Index (MPI) revealed a non-significant statistically difference on comparing results of 3 months and 6 months postoperatively (p=0.298). Probing Depth(PD) revealed a nonsignificant statistically difference on comparing results of 3 months and 6 months postoperatively (p=1 at 3 months, p=0.591 at 6 months). Stability: the mean value increased by time from baseline to after 6 months in Group I (61.57±6.4 to 71.57±6.08), however, the mean value increased from 63.14±7.17 to 74.57±5.53 in Group II. Implant stability revealed nonsignificant statistically differences for p-values (P 0.05). Radiographic results: Bone Density (BD):The statistical analysis between the two groups in the mean percent change in bone density revealed a non-significant statistically difference between the 6 months results. It was 1.88±1.37% for the first group and 11.54±15.63% for the second group (p=0.20).Conclusions: Conical and cylindrical implants have comparable biological effects during the healing process. The properties of the bone site can influence the stability of the implant. Codex : 14/21.10 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.46699.1305 Oral Medicine & Surgical Sciences (Oral Medicine, Oral & Maxillofacial Surgery, Oral Pathology, Oral Biology)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficacy of Aloe vera in Treatment of Experimentally Induced Oral Lichenoid Reaction Evaluation of Local Versus Intravenous Administration of Adipose Tissue-Derived Stem Cells on Regeneration of Oral Epithelium of Chemotherapy Treated Rats The Influence of Different Implant Abutment Sizes on Fracture Resistance of Two Monolithic Ceramic Crown Systems Effect of Irradiation with 980-nm Diode Laser on the Microhardness of Young and Old Root Canal Dentin after Treatment with Chemical Solutions Evaluation of Occlusal Pressure Pattern and Dimensional Changes of the Lined Dentures Subjected to Microwave Disinfection Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1