利用超高密度制图系统研究周期长短交替的大可入心性房性心动过速机制。

Jin-lin Zhang, Liangrong Zheng, Dongchen Zhou, Anquan Zhao, Cheng Tang, Yong-hua Zhang, X. Su
{"title":"利用超高密度制图系统研究周期长短交替的大可入心性房性心动过速机制。","authors":"Jin-lin Zhang, Liangrong Zheng, Dongchen Zhou, Anquan Zhao, Cheng Tang, Yong-hua Zhang, X. Su","doi":"10.1161/CIRCEP.119.007634","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nAtrial tachycardia (AT) with cycle length (CL) alternans is a rare phenomenon. We aimed to identify the characteristics and precise mechanism of this special category of ATs by using an ultrahigh density mapping system.\n\n\nMETHODS\nWe identified 7 ATs with alternating CL in a total of 478 ATs from 2 institutions mapped with an ultrahigh density mapping system. Activation maps were performed for long CL (289±35 ms; mapping points, 21 520±11 103) and short CL (251±18 ms; mapping points,17 594±8059) separately.\n\n\nRESULTS\nWe classified ATs with CL alternans into 2 types. Type 1: There existed 2 potential loops with different routes. CL alternans resulted from an intermittently 2:1 conducting block within the channel of the smaller loop. Type 2: CL alternans resulted from different conduction velocity through 2 closely spaced gaps within preexisting linear lesions. Catheter ablation successfully terminated all the 7 ATs.\n\n\nCONCLUSIONS\nUltrahigh density mapping provides an opportunity to delineate the precise mechanism of AT with CL alternans. Intermittent conduction block or slowing of a channel was essential for the maintenance of AT.","PeriodicalId":10167,"journal":{"name":"Circulation: Arrhythmia and Electrophysiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Insight Into the Mechanism of Macroreentrant Atrial Tachycardia With Cycle Length Alternans Using Ultrahigh Density Mapping System.\",\"authors\":\"Jin-lin Zhang, Liangrong Zheng, Dongchen Zhou, Anquan Zhao, Cheng Tang, Yong-hua Zhang, X. Su\",\"doi\":\"10.1161/CIRCEP.119.007634\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\nAtrial tachycardia (AT) with cycle length (CL) alternans is a rare phenomenon. We aimed to identify the characteristics and precise mechanism of this special category of ATs by using an ultrahigh density mapping system.\\n\\n\\nMETHODS\\nWe identified 7 ATs with alternating CL in a total of 478 ATs from 2 institutions mapped with an ultrahigh density mapping system. Activation maps were performed for long CL (289±35 ms; mapping points, 21 520±11 103) and short CL (251±18 ms; mapping points,17 594±8059) separately.\\n\\n\\nRESULTS\\nWe classified ATs with CL alternans into 2 types. Type 1: There existed 2 potential loops with different routes. CL alternans resulted from an intermittently 2:1 conducting block within the channel of the smaller loop. Type 2: CL alternans resulted from different conduction velocity through 2 closely spaced gaps within preexisting linear lesions. Catheter ablation successfully terminated all the 7 ATs.\\n\\n\\nCONCLUSIONS\\nUltrahigh density mapping provides an opportunity to delineate the precise mechanism of AT with CL alternans. Intermittent conduction block or slowing of a channel was essential for the maintenance of AT.\",\"PeriodicalId\":10167,\"journal\":{\"name\":\"Circulation: Arrhythmia and Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation: Arrhythmia and Electrophysiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCEP.119.007634\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation: Arrhythmia and Electrophysiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1161/CIRCEP.119.007634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

背景:伴周期长度交替的性心动过速(AT)是一种罕见的现象。我们的目的是利用超高密度制图系统来确定这一特殊类别的ATs的特征和精确机制。方法从2个机构的478个ATs中筛选出7个具有交替CL的ATs。长CL(289±35 ms)时绘制激活图;测图点,21 520±11 103)和短CL(251±18 ms);测绘点分别为17 594±8059)。结果将伴有CL交替的ATs分为2种类型。类型1:存在2个不同路径的潜在环路。CL交替是由较小回路通道内间歇性2:1传导阻滞引起的。2型:CL交替是由先前存在的线状病变内2个紧密间隔的间隙的传导速度不同引起的。导管消融均成功终止7例ATs。结论超高密度成像为准确描述AT与CL交替的机制提供了机会。间歇性传导阻滞或通道减慢对于AT的维持至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Insight Into the Mechanism of Macroreentrant Atrial Tachycardia With Cycle Length Alternans Using Ultrahigh Density Mapping System.
BACKGROUND Atrial tachycardia (AT) with cycle length (CL) alternans is a rare phenomenon. We aimed to identify the characteristics and precise mechanism of this special category of ATs by using an ultrahigh density mapping system. METHODS We identified 7 ATs with alternating CL in a total of 478 ATs from 2 institutions mapped with an ultrahigh density mapping system. Activation maps were performed for long CL (289±35 ms; mapping points, 21 520±11 103) and short CL (251±18 ms; mapping points,17 594±8059) separately. RESULTS We classified ATs with CL alternans into 2 types. Type 1: There existed 2 potential loops with different routes. CL alternans resulted from an intermittently 2:1 conducting block within the channel of the smaller loop. Type 2: CL alternans resulted from different conduction velocity through 2 closely spaced gaps within preexisting linear lesions. Catheter ablation successfully terminated all the 7 ATs. CONCLUSIONS Ultrahigh density mapping provides an opportunity to delineate the precise mechanism of AT with CL alternans. Intermittent conduction block or slowing of a channel was essential for the maintenance of AT.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Coronary Sinus Metabolite 12,13-diHOME Is a Novel Biomarker for Left Atrial Remodeling in Patients With Atrial Fibrillation Impact of Contact Force on Pulsed Field Ablation Outcomes Using Focal Point Catheter Characteristics of Right-Sided Accessory Pathways Associated With Right Cardiac Veins Prognostic Impact of Sinus Rhythm in Atrial Fibrillation Patients: Separating Rhythm Outcomes From Randomized Strategy Findings From the CABANA Trial Trends Favoring an Anatomical Approach to Radiofrequency Catheter Ablation of Idiopathic Ventricular Arrhythmias Originating From the Left Ventricular Summit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1