离子交换材料中转移数的评定方法

Mykola Koshel, Sergiy Koshel, S. Korpach
{"title":"离子交换材料中转移数的评定方法","authors":"Mykola Koshel, Sergiy Koshel, S. Korpach","doi":"10.33609/2708-129x.88.08.2022.79-96","DOIUrl":null,"url":null,"abstract":"A new method of differential itn-metry has been developed for accurate determination of ion transfer numbers in materials with ion-exchange properties. Such materials include ion exchange membranes, liquid phase ion exchangers and ionic liquids, industrial ion exchange resins. The method is intended as an alternative simplified assessment of the functional properties of ion-exchange resins used in industrial technologies of water purification, water treatment, and extraction at enterprises of various industries. Such accurate information is obtained in special laboratories at enterprises by long-term and expensive physical and chemical methods. Transfer numbers give an indirect assessment of the quality of ion exchangers, but the method of differential itn-metry gives a result in a short 30-minute experiment on the electrolysis of a NaOH or NaCl solution in a three-chamber electrolyzer reactor. The electrolyzer-reactor contains an electrolyte volume of up to 40 cm3. The middle chamber of the electrolyzer-reactor has a variable width from 0.05 to 0.2 cm and an area of 10 cm2 perpendicular to the direction of the electric current. \nThe primary result of each experiment was the functions of the electrolyte concentration dynamics C(τ) in the extreme cathode and anode chambers of the electrolyzer- reactor, where the dynamics of the readings of the flow resistometric sensor developed by us were recorded during the electrolysis process. The effective transfer number itn* was determined by mathematical data processing using a system of approximation functions. \nThe method of differential itn-metry will be effective for other resins with amphoteric properties. The use of such a method could be used in works for the study of a wide range of problems in environmental monitoring and management of environmental projects.","PeriodicalId":23394,"journal":{"name":"Ukrainian Chemistry Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"METHOD OF EVALUATION OF TRANSFER NUMBERS IN ION-EXCHANGE MATERIALS\",\"authors\":\"Mykola Koshel, Sergiy Koshel, S. Korpach\",\"doi\":\"10.33609/2708-129x.88.08.2022.79-96\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new method of differential itn-metry has been developed for accurate determination of ion transfer numbers in materials with ion-exchange properties. Such materials include ion exchange membranes, liquid phase ion exchangers and ionic liquids, industrial ion exchange resins. The method is intended as an alternative simplified assessment of the functional properties of ion-exchange resins used in industrial technologies of water purification, water treatment, and extraction at enterprises of various industries. Such accurate information is obtained in special laboratories at enterprises by long-term and expensive physical and chemical methods. Transfer numbers give an indirect assessment of the quality of ion exchangers, but the method of differential itn-metry gives a result in a short 30-minute experiment on the electrolysis of a NaOH or NaCl solution in a three-chamber electrolyzer reactor. The electrolyzer-reactor contains an electrolyte volume of up to 40 cm3. The middle chamber of the electrolyzer-reactor has a variable width from 0.05 to 0.2 cm and an area of 10 cm2 perpendicular to the direction of the electric current. \\nThe primary result of each experiment was the functions of the electrolyte concentration dynamics C(τ) in the extreme cathode and anode chambers of the electrolyzer- reactor, where the dynamics of the readings of the flow resistometric sensor developed by us were recorded during the electrolysis process. The effective transfer number itn* was determined by mathematical data processing using a system of approximation functions. \\nThe method of differential itn-metry will be effective for other resins with amphoteric properties. The use of such a method could be used in works for the study of a wide range of problems in environmental monitoring and management of environmental projects.\",\"PeriodicalId\":23394,\"journal\":{\"name\":\"Ukrainian Chemistry Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ukrainian Chemistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33609/2708-129x.88.08.2022.79-96\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Chemistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33609/2708-129x.88.08.2022.79-96","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为准确测定具有离子交换性质的材料中的离子转移数,提出了一种新的差分滴定法。这类材料包括离子交换膜、液相离子交换剂和离子液体、工业离子交换树脂。该方法旨在作为一种替代的简化评估离子交换树脂的功能特性,用于工业技术的水净化,水处理,并在各行各业的企业提取。这种准确的信息是在企业的专门实验室中通过长期和昂贵的物理和化学方法获得的。转移数对离子交换剂的质量给出了一个间接的评价,但微分滴定法给出了在三室电解槽反应器中电解NaOH或NaCl溶液的30分钟的实验结果。电解槽-反应器的电解液体积可达40立方厘米。电解槽-反应器的中间腔室宽度为0.05 ~ 0.2 cm,垂直于电流方向的面积为10 cm2。每个实验的主要结果是电解槽-反应器的极阴极和极阳极室中电解质浓度动态C(τ)的函数,其中我们开发的流量电阻传感器在电解过程中记录了读数的动态。有效传递数itn*采用近似函数系统进行数学数据处理确定。该方法对其他具有两性性质的树脂也是有效的。这种方法的使用可用于研究环境监测和环境项目管理中的一系列广泛问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
METHOD OF EVALUATION OF TRANSFER NUMBERS IN ION-EXCHANGE MATERIALS
A new method of differential itn-metry has been developed for accurate determination of ion transfer numbers in materials with ion-exchange properties. Such materials include ion exchange membranes, liquid phase ion exchangers and ionic liquids, industrial ion exchange resins. The method is intended as an alternative simplified assessment of the functional properties of ion-exchange resins used in industrial technologies of water purification, water treatment, and extraction at enterprises of various industries. Such accurate information is obtained in special laboratories at enterprises by long-term and expensive physical and chemical methods. Transfer numbers give an indirect assessment of the quality of ion exchangers, but the method of differential itn-metry gives a result in a short 30-minute experiment on the electrolysis of a NaOH or NaCl solution in a three-chamber electrolyzer reactor. The electrolyzer-reactor contains an electrolyte volume of up to 40 cm3. The middle chamber of the electrolyzer-reactor has a variable width from 0.05 to 0.2 cm and an area of 10 cm2 perpendicular to the direction of the electric current. The primary result of each experiment was the functions of the electrolyte concentration dynamics C(τ) in the extreme cathode and anode chambers of the electrolyzer- reactor, where the dynamics of the readings of the flow resistometric sensor developed by us were recorded during the electrolysis process. The effective transfer number itn* was determined by mathematical data processing using a system of approximation functions. The method of differential itn-metry will be effective for other resins with amphoteric properties. The use of such a method could be used in works for the study of a wide range of problems in environmental monitoring and management of environmental projects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
SOLVATOCHROMIC PROPERTIES OF SOME 6,7-DIHYDROXYBENZOPYRYLLIUM PERCHLORATE DERIVATIVES ACHIEVEMENTS IN PHYSICAL CHEMISTRY IN THE FIELD OF MICROSCOPY AND VISUALIZATION OF NANOSYSTEMS SYNTHESIS AND STUDY OF NANO-SIZED COMPLEX OF Fe(III) WITH ETHYLENEDIAMINEDISUCCINIC ACID EFFECT OF POLYMER MODIFIER ON THE MOR­PHO­LOGICAL AND SEPARATION PROPERTIES OF ASYMMETRIC MICROFILTRATION MEMBRANES ARYLTELLUROCHLORINATION OF 5-ARYL(HETERYL)SUBSTITUTED N-ALLYL-1,2,4-TRIAZOLE-3-THIONE DERIVATIVES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1