G. Park, Seungmok Kim, Seung-ho Han, Geun-jun Lyu, Yeon-jae Lee
{"title":"综合阴极保护监测器的现场试验与性能分析","authors":"G. Park, Seungmok Kim, Seung-ho Han, Geun-jun Lyu, Yeon-jae Lee","doi":"10.1109/ICCAS.2015.7364863","DOIUrl":null,"url":null,"abstract":"In this paper, we developed and tested comparison performance of our developed Integrated Cathodic Protection Monitor (ICPM) with other instruments. ICPM is more accurate than other products due to using high impedances(100MO) to fit high soil specific resistances. And we achieved measuring of corrosion protection voltages at the fields and comparing of those data with other instruments. We demonstrated our ICPM more excellent than other products through experiments.","PeriodicalId":6641,"journal":{"name":"2015 15th International Conference on Control, Automation and Systems (ICCAS)","volume":"101 1","pages":"1417-1420"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Field test and performance analysis of Integrated Cathodic Protection Monitors\",\"authors\":\"G. Park, Seungmok Kim, Seung-ho Han, Geun-jun Lyu, Yeon-jae Lee\",\"doi\":\"10.1109/ICCAS.2015.7364863\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we developed and tested comparison performance of our developed Integrated Cathodic Protection Monitor (ICPM) with other instruments. ICPM is more accurate than other products due to using high impedances(100MO) to fit high soil specific resistances. And we achieved measuring of corrosion protection voltages at the fields and comparing of those data with other instruments. We demonstrated our ICPM more excellent than other products through experiments.\",\"PeriodicalId\":6641,\"journal\":{\"name\":\"2015 15th International Conference on Control, Automation and Systems (ICCAS)\",\"volume\":\"101 1\",\"pages\":\"1417-1420\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 15th International Conference on Control, Automation and Systems (ICCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCAS.2015.7364863\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 15th International Conference on Control, Automation and Systems (ICCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCAS.2015.7364863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Field test and performance analysis of Integrated Cathodic Protection Monitors
In this paper, we developed and tested comparison performance of our developed Integrated Cathodic Protection Monitor (ICPM) with other instruments. ICPM is more accurate than other products due to using high impedances(100MO) to fit high soil specific resistances. And we achieved measuring of corrosion protection voltages at the fields and comparing of those data with other instruments. We demonstrated our ICPM more excellent than other products through experiments.