一种新型包覆氯胺酮银电极电位法测定安瓿和尿样中盐酸氯胺酮

Hazem M. Abu Shawish , Salman M. Saadeh , Hassan Tamos , Khalid I. Abed-Almonem , osama Al khalili
{"title":"一种新型包覆氯胺酮银电极电位法测定安瓿和尿样中盐酸氯胺酮","authors":"Hazem M. Abu Shawish ,&nbsp;Salman M. Saadeh ,&nbsp;Hassan Tamos ,&nbsp;Khalid I. Abed-Almonem ,&nbsp;osama Al khalili","doi":"10.1016/j.ancr.2014.10.003","DOIUrl":null,"url":null,"abstract":"<div><p>A new ketamine coated silver electrode (KCSE) based on ketamine hydrochloride with sodium tetraphenylborate (KT-TPB) as electroactive material has been described. The influence of membrane composition, type of solvent mediators, kind of electroactive materials and interfering ions on the sensor was investigated. The sensor displays Nernstian response of 55.8<!--> <!-->±<!--> <!-->0.3<!--> <!-->mV/decade over the concentration range of 2.5<!--> <!-->×<!--> <!-->10<sup>−6</sup> to 1.0<!--> <!-->×<!--> <!-->10<sup>−2</sup> <!-->M with limit of detection of 8.5<!--> <!-->×<!--> <!-->10<sup>−7</sup> <!-->M. The coated wire electrode has short response time ∼8<!--> <!-->s and it can be used in pH range of 2.6–6.4. The selective coefficients were determined in relation to several inorganic, organic ions, sugars and some common drug excipients. The KCSE electrode was successfully used for the determination of the ketamine content in ampoule and urine samples with satisfactory results. Statistical student’s <em>t</em>-test and <em>F</em> test showed insignificant systematic error between proposed and official methods.</p></div>","PeriodicalId":7819,"journal":{"name":"Analytical Chemistry Research","volume":"2 ","pages":"Pages 30-36"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ancr.2014.10.003","citationCount":"16","resultStr":"{\"title\":\"A novel coated silver ketamine(I) electrode for potentiometric determination of ketamine hydrochloride in ampoules and urine samples\",\"authors\":\"Hazem M. Abu Shawish ,&nbsp;Salman M. Saadeh ,&nbsp;Hassan Tamos ,&nbsp;Khalid I. Abed-Almonem ,&nbsp;osama Al khalili\",\"doi\":\"10.1016/j.ancr.2014.10.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A new ketamine coated silver electrode (KCSE) based on ketamine hydrochloride with sodium tetraphenylborate (KT-TPB) as electroactive material has been described. The influence of membrane composition, type of solvent mediators, kind of electroactive materials and interfering ions on the sensor was investigated. The sensor displays Nernstian response of 55.8<!--> <!-->±<!--> <!-->0.3<!--> <!-->mV/decade over the concentration range of 2.5<!--> <!-->×<!--> <!-->10<sup>−6</sup> to 1.0<!--> <!-->×<!--> <!-->10<sup>−2</sup> <!-->M with limit of detection of 8.5<!--> <!-->×<!--> <!-->10<sup>−7</sup> <!-->M. The coated wire electrode has short response time ∼8<!--> <!-->s and it can be used in pH range of 2.6–6.4. The selective coefficients were determined in relation to several inorganic, organic ions, sugars and some common drug excipients. The KCSE electrode was successfully used for the determination of the ketamine content in ampoule and urine samples with satisfactory results. Statistical student’s <em>t</em>-test and <em>F</em> test showed insignificant systematic error between proposed and official methods.</p></div>\",\"PeriodicalId\":7819,\"journal\":{\"name\":\"Analytical Chemistry Research\",\"volume\":\"2 \",\"pages\":\"Pages 30-36\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.ancr.2014.10.003\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214181214000251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214181214000251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

以四苯基硼酸钠(KT-TPB)为电活性材料,制备了一种新型氯胺酮包覆银电极(KCSE)。考察了膜组成、溶剂介质类型、电活性材料种类和干扰离子对传感器性能的影响。在2.5 × 10−6 ~ 1.0 × 10−2 M的浓度范围内,传感器的Nernstian响应为55.8±0.3 mV/ 10年,检测限为8.5 × 10−7 M。涂层丝电极的响应时间短~ 8 s,可用于2.6 ~ 6.4 pH范围。测定了几种无机离子、有机离子、糖和常用药物辅料的选择系数。KCSE电极用于安瓿和尿液样品中氯胺酮含量的测定,结果满意。统计学生t检验和F检验表明,建议方法和官方方法之间的系统误差不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel coated silver ketamine(I) electrode for potentiometric determination of ketamine hydrochloride in ampoules and urine samples

A new ketamine coated silver electrode (KCSE) based on ketamine hydrochloride with sodium tetraphenylborate (KT-TPB) as electroactive material has been described. The influence of membrane composition, type of solvent mediators, kind of electroactive materials and interfering ions on the sensor was investigated. The sensor displays Nernstian response of 55.8 ± 0.3 mV/decade over the concentration range of 2.5 × 10−6 to 1.0 × 10−2 M with limit of detection of 8.5 × 10−7 M. The coated wire electrode has short response time ∼8 s and it can be used in pH range of 2.6–6.4. The selective coefficients were determined in relation to several inorganic, organic ions, sugars and some common drug excipients. The KCSE electrode was successfully used for the determination of the ketamine content in ampoule and urine samples with satisfactory results. Statistical student’s t-test and F test showed insignificant systematic error between proposed and official methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations Preparation and characterization of a novel Co(II) optode based on polymer inclusion membrane Structural identification and estimation of Rosuvastatin calcium related impurities in Rosuvastatin calcium tablet dosage form Comparative sensing of aldehyde and ammonia vapours on synthetic polypyrrole-Sn(IV)arsenotungstate nanocomposite cation exchange material Nano clay Ni/NiO nanocomposite new sorbent for separation and preconcentration dibenzothiophene from crude prior to UV–vis spectrophotometery determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1