管道工作压力对不同压降率下自动控制阀设定值的影响

M. Mahmoodi, M. G. Bandpy
{"title":"管道工作压力对不同压降率下自动控制阀设定值的影响","authors":"M. Mahmoodi, M. G. Bandpy","doi":"10.22050/IJOGST.2018.105249.1420","DOIUrl":null,"url":null,"abstract":"When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper time. In this study, the effect of characteristic parameters such as pipeline operational pressure (POP) and pipeline pressure drop rate (ROD) due to rupture or a major leak was experimentally investigated on DPS. 25 different conditions with the double set of the mentioned typical characteristic parameters were chosen. In each condition, the differential pressure (DP) was measured over a period of 180 s by statistically analyzing the experimental results, so 25 maximum DP values (DPSs) were obtained. The DPS rises by an increase in ROD or a decrease in POP. Because of using nitrogen gas instead of natural gas for safety reasons and the uncertainties, the DPS results can be practically applied by adding a safety factor of 15%. Finally, the diagram of DPS with respect to ROD and that of non-dimensional DPS (DOP) versus non-dimensional ROD (RTP) were provided for different POP’s.","PeriodicalId":14575,"journal":{"name":"Iranian Journal of Oil and Gas Science and Technology","volume":"205 1","pages":"106-121"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates\",\"authors\":\"M. Mahmoodi, M. G. Bandpy\",\"doi\":\"10.22050/IJOGST.2018.105249.1420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper time. In this study, the effect of characteristic parameters such as pipeline operational pressure (POP) and pipeline pressure drop rate (ROD) due to rupture or a major leak was experimentally investigated on DPS. 25 different conditions with the double set of the mentioned typical characteristic parameters were chosen. In each condition, the differential pressure (DP) was measured over a period of 180 s by statistically analyzing the experimental results, so 25 maximum DP values (DPSs) were obtained. The DPS rises by an increase in ROD or a decrease in POP. Because of using nitrogen gas instead of natural gas for safety reasons and the uncertainties, the DPS results can be practically applied by adding a safety factor of 15%. Finally, the diagram of DPS with respect to ROD and that of non-dimensional DPS (DOP) versus non-dimensional ROD (RTP) were provided for different POP’s.\",\"PeriodicalId\":14575,\"journal\":{\"name\":\"Iranian Journal of Oil and Gas Science and Technology\",\"volume\":\"205 1\",\"pages\":\"106-121\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Oil and Gas Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22050/IJOGST.2018.105249.1420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Oil and Gas Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22050/IJOGST.2018.105249.1420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

当天然气管道破裂时,相邻的上下游自动控制阀(ACV)应迅速关闭,防止泄漏或爆炸。每个阀门位置的压差设定点(DPS)是ACV动作中值设置的主要标准。如果DPS调整不当,可能会导致ACV误关或未及时采取动作。本研究通过实验研究了管道运行压力(POP)和管道破裂或重大泄漏压降率(ROD)等特征参数对DPS的影响。选取了具有上述典型特征参数双集的25种不同条件。通过对实验结果的统计分析,在每一种条件下测量180 s的压差(DP),得到25个最大压差值(DP)。DPS随着ROD的增加或POP的减少而增加。由于安全考虑和不确定性因素,使用氮气代替天然气,因此添加15%的安全系数后,DPS结果可以实际应用。最后,给出了不同POP的DPS与ROD的关系图,以及无量纲DPS (DOP)与无量纲ROD (RTP)的关系图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates
When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper time. In this study, the effect of characteristic parameters such as pipeline operational pressure (POP) and pipeline pressure drop rate (ROD) due to rupture or a major leak was experimentally investigated on DPS. 25 different conditions with the double set of the mentioned typical characteristic parameters were chosen. In each condition, the differential pressure (DP) was measured over a period of 180 s by statistically analyzing the experimental results, so 25 maximum DP values (DPSs) were obtained. The DPS rises by an increase in ROD or a decrease in POP. Because of using nitrogen gas instead of natural gas for safety reasons and the uncertainties, the DPS results can be practically applied by adding a safety factor of 15%. Finally, the diagram of DPS with respect to ROD and that of non-dimensional DPS (DOP) versus non-dimensional ROD (RTP) were provided for different POP’s.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Relation between asphaltene adsorption on the nanoparticles surface and asphaltene precipitation inhibition during real crude oil natural depletion tests Evaluation of a novel mechanistic approach to predict transport of water and ions through shale Investigation of origin, sedimentary environment and preservation of organic matter: A case study in Garau Formation Detection of heavy bitumen contaminations with using corrected Rock-Eval pyrolysis data Geochemical Investigation of Trace Metals in Crude Oils from Some Producing Oil Fields in Niger Delta, Nigeria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1