健康受试者宫颈多裂肌康复超声显像的组内可靠性

B. Czechowska, Katarzyna Gilbov, Marcin Świątczak
{"title":"健康受试者宫颈多裂肌康复超声显像的组内可靠性","authors":"B. Czechowska, Katarzyna Gilbov, Marcin Świątczak","doi":"10.5114/FOR.2021.106948","DOIUrl":null,"url":null,"abstract":"Background: The multifidus muscle is a deep muscle and the main stabiliser of the spine. Ab normal activity and morphology of this muscle can provoke cervical spinal pain. One way to as sess the morphology of deep stabilising muscles is ultrasonography. There is limited evidence on the reliability of measuring the multifidus muscle in the cervical region of the spine using rehabili tative ultrasound imaging (RUSI). Aims: This study aimed to evaluate the reliabili ty of measuring the cross-sectional area, surface area, and circumference of the multifidus muscle in the cervical region of the spine Material and methods: The study involved 10 heal thy subjects, including 7 women and 3 men, aged 23–62 years. The cross-sectional area, circumfe rence, and surface area of the multifidus musc le in the cervical section of the spine were me asured in the subjects using RUSI. The intraclass correlation coefficient (ICC) was used for each measurement (3.1–3.3) as recommended index for the intra-rater reliability assessment. Results: Taking measurements twice, with a 15-minute interval between them, increased the reliability of measurements of the cross-sectio nal area, surface area, and circumference of the multifidus muscle in the cervical section of the spine to ICC > 0.9, which indicates excellent relia bility. The mean of the three measurements de creased the ICC value to 0.8–0.9, showing good reliability of the measurements. The ICC 3.3 va lues for measurements of the area and circum ference of the multifidus muscle in the cervical region of the spine performed after seven days were lower, in the range of 0.48–0.55, which sug gests questionable reliability of measurements. The value of ICC 3.3 of the cross-sectional area also decreased, although it remained in the upper limit (0.85), demonstrating good reliability of the measurement. Conclusions: The RUSI is a reliable tool for asses sing the morphology of the multifidus muscle in the cervical spine region.","PeriodicalId":88183,"journal":{"name":"The Physiotherapy review","volume":"73 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects\",\"authors\":\"B. Czechowska, Katarzyna Gilbov, Marcin Świątczak\",\"doi\":\"10.5114/FOR.2021.106948\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The multifidus muscle is a deep muscle and the main stabiliser of the spine. Ab normal activity and morphology of this muscle can provoke cervical spinal pain. One way to as sess the morphology of deep stabilising muscles is ultrasonography. There is limited evidence on the reliability of measuring the multifidus muscle in the cervical region of the spine using rehabili tative ultrasound imaging (RUSI). Aims: This study aimed to evaluate the reliabili ty of measuring the cross-sectional area, surface area, and circumference of the multifidus muscle in the cervical region of the spine Material and methods: The study involved 10 heal thy subjects, including 7 women and 3 men, aged 23–62 years. The cross-sectional area, circumfe rence, and surface area of the multifidus musc le in the cervical section of the spine were me asured in the subjects using RUSI. The intraclass correlation coefficient (ICC) was used for each measurement (3.1–3.3) as recommended index for the intra-rater reliability assessment. Results: Taking measurements twice, with a 15-minute interval between them, increased the reliability of measurements of the cross-sectio nal area, surface area, and circumference of the multifidus muscle in the cervical section of the spine to ICC > 0.9, which indicates excellent relia bility. The mean of the three measurements de creased the ICC value to 0.8–0.9, showing good reliability of the measurements. The ICC 3.3 va lues for measurements of the area and circum ference of the multifidus muscle in the cervical region of the spine performed after seven days were lower, in the range of 0.48–0.55, which sug gests questionable reliability of measurements. The value of ICC 3.3 of the cross-sectional area also decreased, although it remained in the upper limit (0.85), demonstrating good reliability of the measurement. Conclusions: The RUSI is a reliable tool for asses sing the morphology of the multifidus muscle in the cervical spine region.\",\"PeriodicalId\":88183,\"journal\":{\"name\":\"The Physiotherapy review\",\"volume\":\"73 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Physiotherapy review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/FOR.2021.106948\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Physiotherapy review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/FOR.2021.106948","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:多裂肌是深部肌肉,是脊柱的主要稳定器。该肌肉的正常活动和形态可引起颈椎疼痛。一种评估深层稳定肌形态的方法是超声检查。关于使用康复超声成像(RUSI)测量颈椎区域多裂肌的可靠性的证据有限。目的:本研究旨在评估测量脊柱颈段多裂肌横截面积、表面积和围度的可靠性。材料和方法:本研究纳入10例健康受试者,其中女性7例,男性3例,年龄23-62岁。在使用入路成像的受试者中,我们测量了颈椎段多裂肌的横截面积、周长和表面积。每次测量均采用类内相关系数(ICC)(3.1-3.3)作为推荐指标进行组内信度评估。结果:两次测量,间隔15分钟,将脊柱颈段多裂肌横截面积、表面积、周长测量的可靠性提高到ICC > 0.9,可靠性极好。三次测量的平均值将ICC值降低到0.8-0.9,表明测量值具有良好的可靠性。7天后测量颈椎区域多裂肌面积和周长的ICC 3.3值较低,在0.48-0.55范围内,这表明测量的可靠性值得怀疑。横截面积的ICC 3.3值也有所下降,但仍保持在上限(0.85),表明测量的可靠性较好。结论:入路成像是评估颈椎区域多裂肌形态的可靠工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects
Background: The multifidus muscle is a deep muscle and the main stabiliser of the spine. Ab normal activity and morphology of this muscle can provoke cervical spinal pain. One way to as sess the morphology of deep stabilising muscles is ultrasonography. There is limited evidence on the reliability of measuring the multifidus muscle in the cervical region of the spine using rehabili tative ultrasound imaging (RUSI). Aims: This study aimed to evaluate the reliabili ty of measuring the cross-sectional area, surface area, and circumference of the multifidus muscle in the cervical region of the spine Material and methods: The study involved 10 heal thy subjects, including 7 women and 3 men, aged 23–62 years. The cross-sectional area, circumfe rence, and surface area of the multifidus musc le in the cervical section of the spine were me asured in the subjects using RUSI. The intraclass correlation coefficient (ICC) was used for each measurement (3.1–3.3) as recommended index for the intra-rater reliability assessment. Results: Taking measurements twice, with a 15-minute interval between them, increased the reliability of measurements of the cross-sectio nal area, surface area, and circumference of the multifidus muscle in the cervical section of the spine to ICC > 0.9, which indicates excellent relia bility. The mean of the three measurements de creased the ICC value to 0.8–0.9, showing good reliability of the measurements. The ICC 3.3 va lues for measurements of the area and circum ference of the multifidus muscle in the cervical region of the spine performed after seven days were lower, in the range of 0.48–0.55, which sug gests questionable reliability of measurements. The value of ICC 3.3 of the cross-sectional area also decreased, although it remained in the upper limit (0.85), demonstrating good reliability of the measurement. Conclusions: The RUSI is a reliable tool for asses sing the morphology of the multifidus muscle in the cervical spine region.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The impact of rehabilitation on pain complaints and functional efficiency of low back pain syndrome patients that resided at the CRR KRUS Center in Iwonicz Zdrój Assessment of knowledge level of women with urinary incontinence – a single-center online study Influence of high-velocity low amplitude manipulation of the lumbar spine on the activity of motor units of the erector spinal muscles with functional assessment in healthy young people A systematic review of randomized controlled trials concerning degenerative meniscus tears The effect of Vojta therapy on gait parameters in a patient with multiple sclerosis – a case study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1