模拟电场,开发生物芯片,用于操纵生物细胞

Siti Nursyahirah Ahmad Latfi, F. Samsuri
{"title":"模拟电场,开发生物芯片,用于操纵生物细胞","authors":"Siti Nursyahirah Ahmad Latfi, F. Samsuri","doi":"10.1109/ICCSCE.2016.7893549","DOIUrl":null,"url":null,"abstract":"Researchers nowadays prefer biochip technology platform as a medium for conducting the analysis of biological cells where appropriate manipulation techniques like trapping, screening and sorting in a few seconds are required to perform biological cells analysis. Non-uniform AC electric field is required for dielectrophoresis force (DEP) to implement manipulation technique, where the non-uniform AC is generated by microelectrodes designed. The current design has a limitation in term of electric field distribution pattern generated. Thus, ring microarray microelectrode pattern was designed and simulated using COMSOL Multiphysics 4.4 software for implementing one of the main objectives of this study, which is to investigate the electric field distribution resulting from the microelectrodes designed. To optimize the generated DEP force for manipulating biological cells, electric field simulation is very important. The electric field simulation performed by altering some microelectrode geometric design parameters such as the microelectrodes length and the distance between the microelectrodes and the microcavity. The simulation has been shown in this paper. This is intended to simulate the effect of an electric field that results when there are any changes to the geometric design of microelectrodes. Based on the simulation that has been done, the results show the distance between the microelectrodes and microcavity provide more impact in electric field distribution strength compared to the change of the microelectrodes size.","PeriodicalId":6540,"journal":{"name":"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","volume":"81 1","pages":"79-84"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation of electric fields for the development of biochip for the purpose of manipulating biological cells\",\"authors\":\"Siti Nursyahirah Ahmad Latfi, F. Samsuri\",\"doi\":\"10.1109/ICCSCE.2016.7893549\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Researchers nowadays prefer biochip technology platform as a medium for conducting the analysis of biological cells where appropriate manipulation techniques like trapping, screening and sorting in a few seconds are required to perform biological cells analysis. Non-uniform AC electric field is required for dielectrophoresis force (DEP) to implement manipulation technique, where the non-uniform AC is generated by microelectrodes designed. The current design has a limitation in term of electric field distribution pattern generated. Thus, ring microarray microelectrode pattern was designed and simulated using COMSOL Multiphysics 4.4 software for implementing one of the main objectives of this study, which is to investigate the electric field distribution resulting from the microelectrodes designed. To optimize the generated DEP force for manipulating biological cells, electric field simulation is very important. The electric field simulation performed by altering some microelectrode geometric design parameters such as the microelectrodes length and the distance between the microelectrodes and the microcavity. The simulation has been shown in this paper. This is intended to simulate the effect of an electric field that results when there are any changes to the geometric design of microelectrodes. Based on the simulation that has been done, the results show the distance between the microelectrodes and microcavity provide more impact in electric field distribution strength compared to the change of the microelectrodes size.\",\"PeriodicalId\":6540,\"journal\":{\"name\":\"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"volume\":\"81 1\",\"pages\":\"79-84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCSCE.2016.7893549\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCSCE.2016.7893549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前,研究人员更倾向于将生物芯片技术平台作为进行生物细胞分析的媒介,因为需要在几秒钟内进行捕获、筛选和分选等适当的操作技术来进行生物细胞分析。介质电泳力(DEP)需要非均匀的交流电场来实现操纵技术,其中非均匀的交流电场是由设计的微电极产生的。目前的设计在产生电场分布模式方面存在局限性。因此,使用COMSOL Multiphysics 4.4软件设计并模拟了环形微阵列微电极图案,以实现本研究的主要目标之一,即研究所设计的微电极产生的电场分布。为了优化所产生的操纵生物细胞的DEP力,电场模拟是非常重要的。通过改变微电极的几何设计参数,如微电极的长度和微电极与微腔之间的距离,进行电场模拟。本文给出了仿真结果。这是为了模拟当微电极的几何设计发生任何变化时产生的电场效应。仿真结果表明,微电极与微腔之间的距离比微电极尺寸的变化对电场分布强度的影响更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation of electric fields for the development of biochip for the purpose of manipulating biological cells
Researchers nowadays prefer biochip technology platform as a medium for conducting the analysis of biological cells where appropriate manipulation techniques like trapping, screening and sorting in a few seconds are required to perform biological cells analysis. Non-uniform AC electric field is required for dielectrophoresis force (DEP) to implement manipulation technique, where the non-uniform AC is generated by microelectrodes designed. The current design has a limitation in term of electric field distribution pattern generated. Thus, ring microarray microelectrode pattern was designed and simulated using COMSOL Multiphysics 4.4 software for implementing one of the main objectives of this study, which is to investigate the electric field distribution resulting from the microelectrodes designed. To optimize the generated DEP force for manipulating biological cells, electric field simulation is very important. The electric field simulation performed by altering some microelectrode geometric design parameters such as the microelectrodes length and the distance between the microelectrodes and the microcavity. The simulation has been shown in this paper. This is intended to simulate the effect of an electric field that results when there are any changes to the geometric design of microelectrodes. Based on the simulation that has been done, the results show the distance between the microelectrodes and microcavity provide more impact in electric field distribution strength compared to the change of the microelectrodes size.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
RVP-FLMS: A robust variable power fractional LMS algorithm Verification of nine-phase PMSM model in d-q coordinates with mutual couplings Gamified outcomes-based teaching and learning assessment tool for Mapúa Institute of Technology Empirical testing of prototype real-time multi-hop MAC for Wireless Sensor Networks Improving intrusion detection system detection accuracy and reducing learning time by combining selected features selection and parameters optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1