使用氰化钾处理刺激性血清

Sujono Sujono, Sistiyono Sistiyono, Subrata Tri Widada
{"title":"使用氰化钾处理刺激性血清","authors":"Sujono Sujono, Sistiyono Sistiyono, Subrata Tri Widada","doi":"10.26630/jak.v12i1.3813","DOIUrl":null,"url":null,"abstract":"A bad sample gives an invalid laboratory test result. There are several reasons that can cause a sample to be unfit for examination. The serum that most often causes errors are hemolysis, jaundice and lipemia. Icteric serum is serum that is yellow brown due to hyperbilirubinemia (increased levels of bilirubin in the blood). Icteric serum may cause interference with laboratory tests. Icteric serum can affect measurements at a wavelength of 400-500 nm. Examination by the method of oxidase or peroxidase reactions, such as glucose, cholesterol, triglycerides and uric acid can be disrupted. Potassium Ferricyanide is added to oxidize bilirubin to biliverdin before testing, and can reduce absorption disorders. Potassium ferric cyanide can reduce total bilirubin levels (p=0.000) in icteric serum. There were differences in the results of total cholesterol (p=0.000), triglycerides (p=0.019), glucose (p=0.001), total protein (p=0.011), albumin (p=0.004), globulin (p=0.002)","PeriodicalId":17791,"journal":{"name":"Jurnal Media Analis Kesehatan","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penggunaan Kalium Feri Sianida Untuk Pengolahan Serum Ikterik\",\"authors\":\"Sujono Sujono, Sistiyono Sistiyono, Subrata Tri Widada\",\"doi\":\"10.26630/jak.v12i1.3813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A bad sample gives an invalid laboratory test result. There are several reasons that can cause a sample to be unfit for examination. The serum that most often causes errors are hemolysis, jaundice and lipemia. Icteric serum is serum that is yellow brown due to hyperbilirubinemia (increased levels of bilirubin in the blood). Icteric serum may cause interference with laboratory tests. Icteric serum can affect measurements at a wavelength of 400-500 nm. Examination by the method of oxidase or peroxidase reactions, such as glucose, cholesterol, triglycerides and uric acid can be disrupted. Potassium Ferricyanide is added to oxidize bilirubin to biliverdin before testing, and can reduce absorption disorders. Potassium ferric cyanide can reduce total bilirubin levels (p=0.000) in icteric serum. There were differences in the results of total cholesterol (p=0.000), triglycerides (p=0.019), glucose (p=0.001), total protein (p=0.011), albumin (p=0.004), globulin (p=0.002)\",\"PeriodicalId\":17791,\"journal\":{\"name\":\"Jurnal Media Analis Kesehatan\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Media Analis Kesehatan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26630/jak.v12i1.3813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Media Analis Kesehatan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26630/jak.v12i1.3813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

坏样品的实验室检测结果无效。有几个原因可以导致样品不适合检查。最常引起错误的血清是溶血、黄疸和血脂。黄疸血清是由于高胆红素血症(血液中胆红素水平升高)引起的黄褐色血清。黄疸血清可能干扰实验室检查。黄疸血清可影响400-500 nm波长的测量。用氧化酶或过氧化物酶反应的方法检查,如葡萄糖、胆固醇、甘油三酯和尿酸均可中断。检测前加入铁氰化钾将胆红素氧化为胆绿素,可减少吸收障碍。氰化铁钾可降低黄疸血清中总胆红素水平(p=0.000)。总胆固醇(p=0.000)、甘油三酯(p=0.019)、葡萄糖(p=0.001)、总蛋白(p=0.011)、白蛋白(p=0.004)、球蛋白(p=0.002)的检测结果存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Penggunaan Kalium Feri Sianida Untuk Pengolahan Serum Ikterik
A bad sample gives an invalid laboratory test result. There are several reasons that can cause a sample to be unfit for examination. The serum that most often causes errors are hemolysis, jaundice and lipemia. Icteric serum is serum that is yellow brown due to hyperbilirubinemia (increased levels of bilirubin in the blood). Icteric serum may cause interference with laboratory tests. Icteric serum can affect measurements at a wavelength of 400-500 nm. Examination by the method of oxidase or peroxidase reactions, such as glucose, cholesterol, triglycerides and uric acid can be disrupted. Potassium Ferricyanide is added to oxidize bilirubin to biliverdin before testing, and can reduce absorption disorders. Potassium ferric cyanide can reduce total bilirubin levels (p=0.000) in icteric serum. There were differences in the results of total cholesterol (p=0.000), triglycerides (p=0.019), glucose (p=0.001), total protein (p=0.011), albumin (p=0.004), globulin (p=0.002)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PENGARUH PEMBERIAN COOKIES DENGAN PENAMBAHAN TEPUNG TEMPE DAN KACANG MERAH TERHADAP PENINGKATAN BERAT BADAN BALITA GIZI KURANG STATUS GIZI ANAK SEKOLAH DI MI DARUSSALAM KOTA BENGKULU Pola Konsumsi Makanan Sumber Asam Lemak Trans pada mahasiswa PTS Kota Bengkulu di Era Pandemi Covid 19 Assessment of the Cytotoxic Effects of Dimethyl Sulfoxide (DMSO) on MCF-7 and HeLa Cell Line GAMBARAN AKTIVITAS ENZIM Aspartat aminotransferase (AST) PADA PEROKOK AKTIF 10-15 TAHUN DI WILAYAH KECAMATAN KAMPUNG MELAYU KOTA BENGKULU
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1