{"title":"阻抗性PSA免疫传感器:前列腺特异性抗原生物传感器","authors":"C. Ching, Tzong-Ru Chou, T. Sun, H. Shieh","doi":"10.1109/ICBEB.2012.247","DOIUrl":null,"url":null,"abstract":"Regular check of blood prostate specific antigen (PSA) level is very important as it is related to prostate cancer. Hence, this study aims to build up a novel impedimetric PSA immumosensor (PSA-IMS) for accurate measurement of PSA. The impedimetric PSA-IMS was fabricated with PSA antibody immobilized on screen-printed carbon electrodes. Impedance measurement at a specific frequency ranges (22.80 Hz - 2.57 kHz) showed that the PSA-IMS has an excellent response range (6.25 - 400 ng/mL), with r2>;0.9, which covers the normal physiological and pathological ranges of blood PSA levels. Intraclass correlation coefficient (ICC) showed that the PSA-IMS has excellent reliability and validit (ICC>;0.95). In conclusion, a simple and reliable PSA-IMS was developed and it is capable of precisely determining blood PSA levels in the range of pathological and normal physiological regions. in both the normal physiological and pathological ranges.","PeriodicalId":6374,"journal":{"name":"2012 International Conference on Biomedical Engineering and Biotechnology","volume":"38 1","pages":"329-331"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Impedimetric PSA Immunosensor: Prostate Specific Antigen Biosensor\",\"authors\":\"C. Ching, Tzong-Ru Chou, T. Sun, H. Shieh\",\"doi\":\"10.1109/ICBEB.2012.247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Regular check of blood prostate specific antigen (PSA) level is very important as it is related to prostate cancer. Hence, this study aims to build up a novel impedimetric PSA immumosensor (PSA-IMS) for accurate measurement of PSA. The impedimetric PSA-IMS was fabricated with PSA antibody immobilized on screen-printed carbon electrodes. Impedance measurement at a specific frequency ranges (22.80 Hz - 2.57 kHz) showed that the PSA-IMS has an excellent response range (6.25 - 400 ng/mL), with r2>;0.9, which covers the normal physiological and pathological ranges of blood PSA levels. Intraclass correlation coefficient (ICC) showed that the PSA-IMS has excellent reliability and validit (ICC>;0.95). In conclusion, a simple and reliable PSA-IMS was developed and it is capable of precisely determining blood PSA levels in the range of pathological and normal physiological regions. in both the normal physiological and pathological ranges.\",\"PeriodicalId\":6374,\"journal\":{\"name\":\"2012 International Conference on Biomedical Engineering and Biotechnology\",\"volume\":\"38 1\",\"pages\":\"329-331\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Biomedical Engineering and Biotechnology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEB.2012.247\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Biomedical Engineering and Biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEB.2012.247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impedimetric PSA Immunosensor: Prostate Specific Antigen Biosensor
Regular check of blood prostate specific antigen (PSA) level is very important as it is related to prostate cancer. Hence, this study aims to build up a novel impedimetric PSA immumosensor (PSA-IMS) for accurate measurement of PSA. The impedimetric PSA-IMS was fabricated with PSA antibody immobilized on screen-printed carbon electrodes. Impedance measurement at a specific frequency ranges (22.80 Hz - 2.57 kHz) showed that the PSA-IMS has an excellent response range (6.25 - 400 ng/mL), with r2>;0.9, which covers the normal physiological and pathological ranges of blood PSA levels. Intraclass correlation coefficient (ICC) showed that the PSA-IMS has excellent reliability and validit (ICC>;0.95). In conclusion, a simple and reliable PSA-IMS was developed and it is capable of precisely determining blood PSA levels in the range of pathological and normal physiological regions. in both the normal physiological and pathological ranges.