W. Yoo, J. Seo, D. Cho, K. Jang, J. Heo, J. Jun, Bongsoo Lee
{"title":"用于射频消融的红外光纤温度阵列传感器","authors":"W. Yoo, J. Seo, D. Cho, K. Jang, J. Heo, J. Jun, Bongsoo Lee","doi":"10.1109/BMEI.2009.5305223","DOIUrl":null,"url":null,"abstract":"We have measured temperature distribution using the infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted single-shaft plain electrode are transferred by the three silver halide optical fibers and are measured by a thermopile sensor array. Also, the output voltages of the thermopile sensor array are compared with those of the thermocouple recorder. It is expected that a non-contact temperature sensor using the infrared optical fibers can be developed for the real time temperature monitoring during RFA treatments based on the results of this study.","PeriodicalId":6389,"journal":{"name":"2009 2nd International Conference on Biomedical Engineering and Informatics","volume":"40 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Infrared Fiber-Optic Temperature Array Sensor for Radiofrequency Ablation\",\"authors\":\"W. Yoo, J. Seo, D. Cho, K. Jang, J. Heo, J. Jun, Bongsoo Lee\",\"doi\":\"10.1109/BMEI.2009.5305223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have measured temperature distribution using the infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted single-shaft plain electrode are transferred by the three silver halide optical fibers and are measured by a thermopile sensor array. Also, the output voltages of the thermopile sensor array are compared with those of the thermocouple recorder. It is expected that a non-contact temperature sensor using the infrared optical fibers can be developed for the real time temperature monitoring during RFA treatments based on the results of this study.\",\"PeriodicalId\":6389,\"journal\":{\"name\":\"2009 2nd International Conference on Biomedical Engineering and Informatics\",\"volume\":\"40 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 2nd International Conference on Biomedical Engineering and Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEI.2009.5305223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 2nd International Conference on Biomedical Engineering and Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEI.2009.5305223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Infrared Fiber-Optic Temperature Array Sensor for Radiofrequency Ablation
We have measured temperature distribution using the infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted single-shaft plain electrode are transferred by the three silver halide optical fibers and are measured by a thermopile sensor array. Also, the output voltages of the thermopile sensor array are compared with those of the thermocouple recorder. It is expected that a non-contact temperature sensor using the infrared optical fibers can be developed for the real time temperature monitoring during RFA treatments based on the results of this study.