{"title":"旋转机械局部放电测量的加工技术","authors":"J. Ortego, E. Arcones, C. Vera, F. Álvarez, F. Garnacho, A. Khamlichi","doi":"10.1109/ICD46958.2020.9342008","DOIUrl":null,"url":null,"abstract":"During the last two decades, the measurement of partial discharges (PD) in rotating electrical machines that operate with high voltages is being the most effective method for detecting defects in their insulation. However, several inconveniences must be overcome by the technical analysts when on-line measurements are carried out. Among them, the most import is the high levels of background noise and interferences which, in many cases, affect significantly in the sensitivity of PD activity detection. In this article, three noise filtering techniques applied in PD measurements performed in a real installation are analyzed. In addition, the benefits of using advanced processing and diagnostic techniques for the evaluation of the dielectrics condition are evidenced. The practical experience presented was carried out in a HV installation comprising the alternator of a hydraulic plant, the plant substation and the insulated cable system that interconnects both parts. The results obtained highlight the importance of applying appropriate signal processing techniques when performing in-situ and on-line PD measurements in rotating machines.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"3 1","pages":"898-901"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Processing techniques applied to partial discharge measuring in rotating machines\",\"authors\":\"J. Ortego, E. Arcones, C. Vera, F. Álvarez, F. Garnacho, A. Khamlichi\",\"doi\":\"10.1109/ICD46958.2020.9342008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During the last two decades, the measurement of partial discharges (PD) in rotating electrical machines that operate with high voltages is being the most effective method for detecting defects in their insulation. However, several inconveniences must be overcome by the technical analysts when on-line measurements are carried out. Among them, the most import is the high levels of background noise and interferences which, in many cases, affect significantly in the sensitivity of PD activity detection. In this article, three noise filtering techniques applied in PD measurements performed in a real installation are analyzed. In addition, the benefits of using advanced processing and diagnostic techniques for the evaluation of the dielectrics condition are evidenced. The practical experience presented was carried out in a HV installation comprising the alternator of a hydraulic plant, the plant substation and the insulated cable system that interconnects both parts. The results obtained highlight the importance of applying appropriate signal processing techniques when performing in-situ and on-line PD measurements in rotating machines.\",\"PeriodicalId\":6795,\"journal\":{\"name\":\"2020 IEEE 3rd International Conference on Dielectrics (ICD)\",\"volume\":\"3 1\",\"pages\":\"898-901\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 3rd International Conference on Dielectrics (ICD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICD46958.2020.9342008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9342008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在过去的二十年中,测量高压旋转电机的局部放电(PD)是检测其绝缘缺陷的最有效方法。然而,在进行在线测量时,技术分析人员必须克服一些不便。其中,最重要的是高水平的背景噪声和干扰,在许多情况下,会显著影响PD活动检测的灵敏度。本文分析了在实际装置中应用于PD测量的三种噪声滤波技术。此外,使用先进的处理和诊断技术来评估电介质状况的好处也得到了证明。介绍的实际经验是在一个高压安装中进行的,该安装包括水力发电厂的交流发电机、工厂变电站和连接这两个部分的绝缘电缆系统。研究结果强调了在旋转机械中进行原位和在线PD测量时应用适当的信号处理技术的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Processing techniques applied to partial discharge measuring in rotating machines
During the last two decades, the measurement of partial discharges (PD) in rotating electrical machines that operate with high voltages is being the most effective method for detecting defects in their insulation. However, several inconveniences must be overcome by the technical analysts when on-line measurements are carried out. Among them, the most import is the high levels of background noise and interferences which, in many cases, affect significantly in the sensitivity of PD activity detection. In this article, three noise filtering techniques applied in PD measurements performed in a real installation are analyzed. In addition, the benefits of using advanced processing and diagnostic techniques for the evaluation of the dielectrics condition are evidenced. The practical experience presented was carried out in a HV installation comprising the alternator of a hydraulic plant, the plant substation and the insulated cable system that interconnects both parts. The results obtained highlight the importance of applying appropriate signal processing techniques when performing in-situ and on-line PD measurements in rotating machines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of Bouncing Metal Particle on Surface Charge Accumulation of A Real Size Epoxy Insulator under DC Voltage Modeling of metallized film capacitors segmented electrodes electrodynamic destruction Fourier Transform Infrared Spectroscopic Analysis of Field Failed 220 kV Polymeric Insulators The confinement effect of BNNT nanofillers on the thermal conductivity of PE from molecular simulation Experimental Study of Synergism in N2 and SF6 Gas Mixtures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1