全景超声评估股外侧肌结构的方法:一种新方法、重测信度和测量误差

A. Soares, F. Nogueira, P. Gomes
{"title":"全景超声评估股外侧肌结构的方法:一种新方法、重测信度和测量误差","authors":"A. Soares, F. Nogueira, P. Gomes","doi":"10.1590/1980-0037.2021V23E76402","DOIUrl":null,"url":null,"abstract":"Abstract Extended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.","PeriodicalId":38989,"journal":{"name":"Revista Brasileira de Cineantropometria e Desempenho Humano","volume":"42 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error\",\"authors\":\"A. Soares, F. Nogueira, P. Gomes\",\"doi\":\"10.1590/1980-0037.2021V23E76402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Extended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.\",\"PeriodicalId\":38989,\"journal\":{\"name\":\"Revista Brasileira de Cineantropometria e Desempenho Humano\",\"volume\":\"42 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Cineantropometria e Desempenho Humano\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/1980-0037.2021V23E76402\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cineantropometria e Desempenho Humano","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1980-0037.2021V23E76402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

扩展视场超声检查是确定骨骼肌尺寸的有效替代方法;然而,一些因素可能会影响最终的测量结果。本研究的目的是通过内部解剖标志确定股外侧肌结构变量的重测信度和测量误差,并利用扩展视场超声比较三个固定测点。研究对象为12名年轻(24±6岁)成年大学生。通过股外侧肌的大视场超声检查获得图像。测量肌肉厚度(MT),肌束长度(FL)和肌束夹角(FA)使用识别内部解剖标志的方法。MT也在近端2厘米、近端6厘米和远端2厘米的预定距离测量。重复测量的单因素方差分析没有发现所有测量变量的任何重测显著差异。典型测量误差以厘米(cm)或度(º)为单位,变异系数以百分比(%)为单位,类内相关系数分别为MT = 0.07 cm、2.93%、0.964;FL = 0.31 cm, 2.89%, 0.947;Fa = 0.92°,4.08%,0.942;MT 2 cm近端= 0.10 cm, 3.77%, 0.910;MT近端6cm = 0.27 cm, 9.66%, 0.576;MT 2 cm远端= 0.35 cm, 19.76%, 0.564。MT、FL和FA具有较高的信度和较低的测量误差。与预定距离方法相比,内部解剖标志被证明更可靠,测量误差更小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
Abstract Extended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
9
审稿时长
20 weeks
期刊介绍: The Brazilian Journal of Kinanthropometry and Human Performance is a journal of Physical Education, Kinesiology, Sport and related areas, whose focus is human movement, being reviewed by an international panel of peers, with emphasis on the measurement of the man in its morphological and functional aspects, as well as conditioning factors of physical performance. Given the multidisciplinary nature of the journal, these areas of study are approached in several contexts, with interactions with social, behavioral, health and environmental aspects. The journal publishes original articles as well as relevant Review/Update articles and Points of View.
期刊最新文献
Talent identification and development in Olympic triathlon: a perspective from Brazilian coaches Factors associated with the practice of physical activity among university students in social isolation during the covid-19 pandemic Association of sex and training phase with physical activity and sedentary behavior in nursing students Influence of walking and running on patellofemoral pain The applicability of the Visceral Adiposity Index (VAI) for predicting visceral fat
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1