基于模型电极系统的聚合物绝缘材料局部放电降解诊断的相位分解研究

F. Komori, A. Kojima, M. Hikita, Y. Suzuoki, T. Mizutani
{"title":"基于模型电极系统的聚合物绝缘材料局部放电降解诊断的相位分解研究","authors":"F. Komori, A. Kojima, M. Hikita, Y. Suzuoki, T. Mizutani","doi":"10.1109/ICSD.1998.709248","DOIUrl":null,"url":null,"abstract":"Using MGI (metal-gap-insulator) and IGI (insulator-gap-insulator) electrode systems with 0.1 mm- or 4.0 mm-thick LDPE samples, we studied the temporal change of PD characteristics. The PD pattern and statistical parameter (PD inception phase) changed with aging time. The IGI electrode system showed a similar change in PD pattern with degradation to that of the MGI electrode system. The PDs in MGI electrodes with the 4.0 mm-thick sample showed new PD characteristics which were absent in the 0.1 mm-thick sample. This was attributed to pit formation just before breakdown. There results suggest the possibility of insulation diagnosis from the beginning to the last stage of PD degradation.","PeriodicalId":13148,"journal":{"name":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","volume":"34 1","pages":"153-156"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Phase-resolved study on partial discharge for degradation diagnosis in polymeric insulating materials using model electrode system\",\"authors\":\"F. Komori, A. Kojima, M. Hikita, Y. Suzuoki, T. Mizutani\",\"doi\":\"10.1109/ICSD.1998.709248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using MGI (metal-gap-insulator) and IGI (insulator-gap-insulator) electrode systems with 0.1 mm- or 4.0 mm-thick LDPE samples, we studied the temporal change of PD characteristics. The PD pattern and statistical parameter (PD inception phase) changed with aging time. The IGI electrode system showed a similar change in PD pattern with degradation to that of the MGI electrode system. The PDs in MGI electrodes with the 4.0 mm-thick sample showed new PD characteristics which were absent in the 0.1 mm-thick sample. This was attributed to pit formation just before breakdown. There results suggest the possibility of insulation diagnosis from the beginning to the last stage of PD degradation.\",\"PeriodicalId\":13148,\"journal\":{\"name\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"volume\":\"34 1\",\"pages\":\"153-156\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1998.709248\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1998.709248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

采用MGI(金属-间隙-绝缘子)和IGI(绝缘子-间隙-绝缘子)电极体系,分别制备了0.1 mm和4.0 mm厚的LDPE样品,研究了PD特性的时间变化。PD模式和统计参数(PD起始相)随老化时间的变化而变化。IGI电极系统显示出与MGI电极系统相似的PD模式随降解的变化。4.0 mm厚MGI电极的PD表现出0.1 mm厚MGI电极所没有的新的PD特征。这是由于在破裂之前形成的坑。结果表明,从PD降解的开始到最后阶段进行绝缘诊断是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phase-resolved study on partial discharge for degradation diagnosis in polymeric insulating materials using model electrode system
Using MGI (metal-gap-insulator) and IGI (insulator-gap-insulator) electrode systems with 0.1 mm- or 4.0 mm-thick LDPE samples, we studied the temporal change of PD characteristics. The PD pattern and statistical parameter (PD inception phase) changed with aging time. The IGI electrode system showed a similar change in PD pattern with degradation to that of the MGI electrode system. The PDs in MGI electrodes with the 4.0 mm-thick sample showed new PD characteristics which were absent in the 0.1 mm-thick sample. This was attributed to pit formation just before breakdown. There results suggest the possibility of insulation diagnosis from the beginning to the last stage of PD degradation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient, finite element-boundary element methods for modeling high field effects in nonhomogeneous solid dielectrics Highly sensitive humidity sensor for dielectric measurement (water absorption) in glass-fiber resins Evaluation of cumulative charge data of polymer insulator aging tests Application of polyethylene sheath and swelling powder against water treeing Surface behaviour of epoxy castings during the early ageing period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1