SF6气体中电极/环氧界面小间隙局部放电特性

D. Mansour, H. Kojima, N. Hayakawa, F. Endo, H. Okubo
{"title":"SF6气体中电极/环氧界面小间隙局部放电特性","authors":"D. Mansour, H. Kojima, N. Hayakawa, F. Endo, H. Okubo","doi":"10.1109/CEIDP.2008.4772884","DOIUrl":null,"url":null,"abstract":"To achieve a safe operation of gas insulated switchgears (GISs), the reliability of electrical insulation is one of the fundamental importance. For this respect, there is an urgent need for better understanding of partial discharge (PD) mechanisms at different locations in GIS. In the current work, the PD inception characteristics at electrode/epoxy interface at insulating spacer in GIS, which represents one of the most critical defects in GIS, are obtained and investigated with different gap lengths, 50~500 mum. Partial discharge inception voltage (PDIV) and electric field (PDIE) are measured and analyzed regarding PD inception mechanism in SF6 gas. Also the dependence of PDIV on repetitive number of PD pulses is obtained and discussed from the viewpoint of accumulated charge on the epoxy surface.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Partial Discharge Characteristics for Small Gap of Electrode/Epoxy Interface in SF6 Gas\",\"authors\":\"D. Mansour, H. Kojima, N. Hayakawa, F. Endo, H. Okubo\",\"doi\":\"10.1109/CEIDP.2008.4772884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To achieve a safe operation of gas insulated switchgears (GISs), the reliability of electrical insulation is one of the fundamental importance. For this respect, there is an urgent need for better understanding of partial discharge (PD) mechanisms at different locations in GIS. In the current work, the PD inception characteristics at electrode/epoxy interface at insulating spacer in GIS, which represents one of the most critical defects in GIS, are obtained and investigated with different gap lengths, 50~500 mum. Partial discharge inception voltage (PDIV) and electric field (PDIE) are measured and analyzed regarding PD inception mechanism in SF6 gas. Also the dependence of PDIV on repetitive number of PD pulses is obtained and discussed from the viewpoint of accumulated charge on the epoxy surface.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772884\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772884","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

为了实现气体绝缘开关设备(GISs)的安全运行,电气绝缘的可靠性是至关重要的基础之一。在这方面,迫切需要更好地了解GIS中不同位置的局部放电机制。本文研究了不同间隙长度(50~500 μ m)下,GIS中最关键的缺陷之一——绝缘隔层电极/环氧树脂界面的PD初始化特性。对SF6气体中局部放电起始电压(PDIV)和电场(PDIE)的起始机理进行了测量和分析。从环氧树脂表面电荷积累的角度出发,讨论了PDIV与脉冲重复次数的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Partial Discharge Characteristics for Small Gap of Electrode/Epoxy Interface in SF6 Gas
To achieve a safe operation of gas insulated switchgears (GISs), the reliability of electrical insulation is one of the fundamental importance. For this respect, there is an urgent need for better understanding of partial discharge (PD) mechanisms at different locations in GIS. In the current work, the PD inception characteristics at electrode/epoxy interface at insulating spacer in GIS, which represents one of the most critical defects in GIS, are obtained and investigated with different gap lengths, 50~500 mum. Partial discharge inception voltage (PDIV) and electric field (PDIE) are measured and analyzed regarding PD inception mechanism in SF6 gas. Also the dependence of PDIV on repetitive number of PD pulses is obtained and discussed from the viewpoint of accumulated charge on the epoxy surface.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Statistical Analysis of Partial Discharges from Electrical Trees Grown in a Flexible Epoxy Resin Comparison of Dielectric Properties of Low-density Polyethylene/MgO Composites with Different Size Fillers Enhanced Performance of Tree Initiation V-t Characteristics of Epoxy/Clay Nanocomposite in Comparison with Neat Epoxy Resin Time and spatial-resolved spectroscopic measurement system of PD light emission and its application to observation of PDs in SF6 gas The Effect of Acetophenone and alpha-Methylstyrene on the Space Charge Properties of Low Density Polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1