反相高效液相色谱法测定人和小鼠血浆中环孢素A的含量

Heleen A. Bardelmeijer , Mariët Ouwehand , Jos H. Beijnen , Jan H.M. Schellens , Olaf van Tellingen
{"title":"反相高效液相色谱法测定人和小鼠血浆中环孢素A的含量","authors":"Heleen A. Bardelmeijer ,&nbsp;Mariët Ouwehand ,&nbsp;Jos H. Beijnen ,&nbsp;Jan H.M. Schellens ,&nbsp;Olaf van Tellingen","doi":"10.1016/S0378-4347(01)00389-9","DOIUrl":null,"url":null,"abstract":"<div><p>An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μ<em>M</em>. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μ<em>M</em> using 500 μl of human plasma and 0.28 μ<em>M</em> using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00389-9","citationCount":"6","resultStr":"{\"title\":\"Determination of cyclosporin A in human and mouse plasma by reversed-phase high-performance liquid chromatography\",\"authors\":\"Heleen A. Bardelmeijer ,&nbsp;Mariët Ouwehand ,&nbsp;Jos H. Beijnen ,&nbsp;Jan H.M. Schellens ,&nbsp;Olaf van Tellingen\",\"doi\":\"10.1016/S0378-4347(01)00389-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μ<em>M</em>. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μ<em>M</em> using 500 μl of human plasma and 0.28 μ<em>M</em> using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.</p></div>\",\"PeriodicalId\":15463,\"journal\":{\"name\":\"Journal of Chromatography B: Biomedical Sciences and Applications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00389-9\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B: Biomedical Sciences and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378434701003899\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B: Biomedical Sciences and Applications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378434701003899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

建立了227 nm紫外检测等容反相高效液相色谱法测定人和小鼠血浆中环孢素A的方法。采用环孢素D类似物psc833作为内标。血浆样品采用二乙醚液液萃取预处理。采用5 μm Nova-Pak苯基材料填充的不锈钢色谱柱,在72℃条件下,以乙腈-甲醇-水(20:52:28,v/v/v)为流动相,环孢素A、内标和两个潜在干扰的内源峰之间实现了良好的色谱分离。人血浆环孢素A浓度在0.11 ~ 5.34 μM范围内呈线性关系。将小鼠血浆样品(200 μl)用空白人血浆稀释至500 μl,从人血浆中制备的校准曲线中读取浓度。500 μl人血浆定量下限为0.11 μM, 200 μl小鼠血浆定量下限为0.28 μM。验证数据表明,该方法测定环孢素a的灵敏度高、选择性好、重复性好,并通过小鼠口服环孢素a的药代动力学实验验证了其适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of cyclosporin A in human and mouse plasma by reversed-phase high-performance liquid chromatography

An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μM. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μM using 500 μl of human plasma and 0.28 μM using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
News Section Influence of various biological matrices (plasma, blood microdialysate) on chromatographic performance in the determination of β-blockers using an alkyl-diol silica precolumn for sample clean-up Highly sensitive analysis of the antifolate pemetrexed sodium, a new cancer agent, in human plasma and urine by high-performance liquid chromatography. Preliminary application of liquid chromatography–electrospray-ionization mass spectrometry to the detection of 5-methyltetrahydrofolic acid monoglutamate in human plasma Improved high-performance liquid chromatographic method to estimate aminosugars and its application to glycosaminoglycan determination in plasma and serum
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1