{"title":"紫外诱导的脱氧核糖核酸激发态。","authors":"R. Rahn, R. Shulman, J. Longworth","doi":"10.2307/3583707","DOIUrl":null,"url":null,"abstract":"All measurements were made at 77?K on samples dissolved in a 1:1 ethylene glycol-water mixture. Concentrations used for making optical measurements were in the range of 10-3 to 10-4 M, while the ESR measurements were made on samples varying from 10-2 to 10-3 M. An Aminco-Bowman spectrophotometer was used to obtain optical data at low resolution for quantitative purposes. For higher resolution, Bausch and Lomb 0.5-meter grating monochromators were used for both excitation and emission. A Varian Associates X-band spectrometer with 100-kc/s modulation was used for the ESR measurements. A 200-watt, high-pressure mercury lamp was used for excitation in the microwave cavity.","PeriodicalId":77888,"journal":{"name":"Radiation research. Supplement","volume":"35 1","pages":"139-46"},"PeriodicalIF":0.0000,"publicationDate":"1967-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Ultraviolet-induced excited states in deoxyribonucleic acid.\",\"authors\":\"R. Rahn, R. Shulman, J. Longworth\",\"doi\":\"10.2307/3583707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"All measurements were made at 77?K on samples dissolved in a 1:1 ethylene glycol-water mixture. Concentrations used for making optical measurements were in the range of 10-3 to 10-4 M, while the ESR measurements were made on samples varying from 10-2 to 10-3 M. An Aminco-Bowman spectrophotometer was used to obtain optical data at low resolution for quantitative purposes. For higher resolution, Bausch and Lomb 0.5-meter grating monochromators were used for both excitation and emission. A Varian Associates X-band spectrometer with 100-kc/s modulation was used for the ESR measurements. A 200-watt, high-pressure mercury lamp was used for excitation in the microwave cavity.\",\"PeriodicalId\":77888,\"journal\":{\"name\":\"Radiation research. Supplement\",\"volume\":\"35 1\",\"pages\":\"139-46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1967-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation research. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2307/3583707\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation research. Supplement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2307/3583707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
所有的测量都是在77?样品上的K溶于1:1的乙二醇-水混合物中。用于光学测量的浓度范围为10-3至10-4 M,而ESR测量的样品范围为10-2至10-3 M。使用Aminco-Bowman分光光度计获得低分辨率的光学数据以进行定量。为了获得更高的分辨率,激发和发射均采用了Bausch and Lomb 0.5 m光栅单色仪。使用瓦里安公司的100 kc/s调制x波段光谱仪进行ESR测量。采用200瓦高压汞灯在微波腔内进行激发。
Ultraviolet-induced excited states in deoxyribonucleic acid.
All measurements were made at 77?K on samples dissolved in a 1:1 ethylene glycol-water mixture. Concentrations used for making optical measurements were in the range of 10-3 to 10-4 M, while the ESR measurements were made on samples varying from 10-2 to 10-3 M. An Aminco-Bowman spectrophotometer was used to obtain optical data at low resolution for quantitative purposes. For higher resolution, Bausch and Lomb 0.5-meter grating monochromators were used for both excitation and emission. A Varian Associates X-band spectrometer with 100-kc/s modulation was used for the ESR measurements. A 200-watt, high-pressure mercury lamp was used for excitation in the microwave cavity.