研究了光伏逆变器在配电网干扰条件下孤岛运行的被动检测方法的性能

IF 1.2 4区 工程技术 Q3 ENGINEERING, MULTIDISCIPLINARY Bulletin of the Polish Academy of Sciences-Technical Sciences Pub Date : 2023-11-06 DOI:10.24425/BPASTS.2020.134658
M. Parol, M. Połecki
{"title":"研究了光伏逆变器在配电网干扰条件下孤岛运行的被动检测方法的性能","authors":"M. Parol, M. Połecki","doi":"10.24425/BPASTS.2020.134658","DOIUrl":null,"url":null,"abstract":"Distributed generation is an issue intensively studied in recent years. It concerns, among others protection systems of distributed generation units connected to electric power grids. The main goal of this paper is to present the issue of functional reliability of selected passive loss of mains (LoM) protection systems, i.e. methods of detecting island operation in distribution power grids, which are implemented in PV inverters installed in sample MV and LV grids, typical for Polish conditions. First, different methods of detecting island operation have been distinguished and shortly characterized. Some problems concerning their action have also been presented. Then commonly used passive methods of island grid operation detection have been described. Next sample distribution grid has been presented and chosen disturbances modelled in the grid to test mentioned passive methods have been defined. For each of the determined type of disturbance the dynamic simulation has been carried out, as well as voltage and frequency plots for two selected RES nodes have been recorded and observed. All considered passive methods of island grid operation detection have been implemented in a Matlab/Simulink environment. Models of RoCoF, U/OVP and U/ OFP algorithms have been presented in diagrams. Then, results of carried out extensive studies have been shown in tables and discussed. The results are a consequence of a realized research project concerning electric grids in rural areas. Summary, final conclusions, and future research possibilities constitute the last part of the paper. The conclusions are mainly concentrated on evaluation of action of passive methods of island operation detection as well as possibility of using the methods in Polish conditions, particularly in rural distribution grids.","PeriodicalId":55299,"journal":{"name":"Bulletin of the Polish Academy of Sciences-Technical Sciences","volume":"78 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The performance of passive methods of detecting island operation implemented in PV inverters during selected disturbances in distribution power grids\",\"authors\":\"M. Parol, M. Połecki\",\"doi\":\"10.24425/BPASTS.2020.134658\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distributed generation is an issue intensively studied in recent years. It concerns, among others protection systems of distributed generation units connected to electric power grids. The main goal of this paper is to present the issue of functional reliability of selected passive loss of mains (LoM) protection systems, i.e. methods of detecting island operation in distribution power grids, which are implemented in PV inverters installed in sample MV and LV grids, typical for Polish conditions. First, different methods of detecting island operation have been distinguished and shortly characterized. Some problems concerning their action have also been presented. Then commonly used passive methods of island grid operation detection have been described. Next sample distribution grid has been presented and chosen disturbances modelled in the grid to test mentioned passive methods have been defined. For each of the determined type of disturbance the dynamic simulation has been carried out, as well as voltage and frequency plots for two selected RES nodes have been recorded and observed. All considered passive methods of island grid operation detection have been implemented in a Matlab/Simulink environment. Models of RoCoF, U/OVP and U/ OFP algorithms have been presented in diagrams. Then, results of carried out extensive studies have been shown in tables and discussed. The results are a consequence of a realized research project concerning electric grids in rural areas. Summary, final conclusions, and future research possibilities constitute the last part of the paper. The conclusions are mainly concentrated on evaluation of action of passive methods of island operation detection as well as possibility of using the methods in Polish conditions, particularly in rural distribution grids.\",\"PeriodicalId\":55299,\"journal\":{\"name\":\"Bulletin of the Polish Academy of Sciences-Technical Sciences\",\"volume\":\"78 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Polish Academy of Sciences-Technical Sciences\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.24425/BPASTS.2020.134658\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Polish Academy of Sciences-Technical Sciences","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.24425/BPASTS.2020.134658","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

分布式发电是近年来研究的热点问题。除其他外,它还涉及连接到电网的分布式发电机组的保护系统。本文的主要目标是提出所选无源市电损耗(LoM)保护系统的功能可靠性问题,即在配电电网中检测孤岛运行的方法,这些方法在安装在样本中压和低压电网中的光伏逆变器中实现,典型的波兰条件。首先,区分了不同的探测岛屿行动的方法,并对其进行了简要的描述。还提出了有关他们行动的一些问题。然后介绍了常用的岛网运行被动检测方法。接下来给出了一个样本配电网,并定义了在电网中建模的干扰来测试上述无源方法。对于每种确定的扰动类型,都进行了动态仿真,并记录和观察了两个选定的RES节点的电压和频率图。在Matlab/Simulink环境下实现了岛上电网运行检测的所有被动方法。RoCoF、U/OVP和U/ OFP算法的模型以图表形式给出。然后,进行了广泛的研究结果已在表格中显示和讨论。这些结果是一个关于农村电网的研究项目的结果。论文的最后一部分是总结、最终结论和未来研究的可能性。结论主要集中在评估被动岛屿运行检测方法的作用以及在波兰条件下使用这些方法的可能性,特别是在农村配电网中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The performance of passive methods of detecting island operation implemented in PV inverters during selected disturbances in distribution power grids
Distributed generation is an issue intensively studied in recent years. It concerns, among others protection systems of distributed generation units connected to electric power grids. The main goal of this paper is to present the issue of functional reliability of selected passive loss of mains (LoM) protection systems, i.e. methods of detecting island operation in distribution power grids, which are implemented in PV inverters installed in sample MV and LV grids, typical for Polish conditions. First, different methods of detecting island operation have been distinguished and shortly characterized. Some problems concerning their action have also been presented. Then commonly used passive methods of island grid operation detection have been described. Next sample distribution grid has been presented and chosen disturbances modelled in the grid to test mentioned passive methods have been defined. For each of the determined type of disturbance the dynamic simulation has been carried out, as well as voltage and frequency plots for two selected RES nodes have been recorded and observed. All considered passive methods of island grid operation detection have been implemented in a Matlab/Simulink environment. Models of RoCoF, U/OVP and U/ OFP algorithms have been presented in diagrams. Then, results of carried out extensive studies have been shown in tables and discussed. The results are a consequence of a realized research project concerning electric grids in rural areas. Summary, final conclusions, and future research possibilities constitute the last part of the paper. The conclusions are mainly concentrated on evaluation of action of passive methods of island operation detection as well as possibility of using the methods in Polish conditions, particularly in rural distribution grids.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
16.70%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The Bulletin of the Polish Academy of Sciences: Technical Sciences is published bimonthly by the Division IV Engineering Sciences of the Polish Academy of Sciences, since the beginning of the existence of the PAS in 1952. The journal is peer‐reviewed and is published both in printed and electronic form. It is established for the publication of original high quality papers from multidisciplinary Engineering sciences with the following topics preferred: Artificial and Computational Intelligence, Biomedical Engineering and Biotechnology, Civil Engineering, Control, Informatics and Robotics, Electronics, Telecommunication and Optoelectronics, Mechanical and Aeronautical Engineering, Thermodynamics, Material Science and Nanotechnology, Power Systems and Power Electronics.
期刊最新文献
148439 148440 Enhancement of COVID-19 symptom-based screening with quality-based classifier optimisation Analyzing and improving tools for supporting fighting against COVID-19 based on prediction models and contact tracing The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1