Mario Buffardo, E. Scione, Catalano Toni Fabio, Carlani Daniele, Ruà Emanuele Giovanni
{"title":"卫星级双重绝缘的实现:一种方法","authors":"Mario Buffardo, E. Scione, Catalano Toni Fabio, Carlani Daniele, Ruà Emanuele Giovanni","doi":"10.1109/ESPC.2019.8932082","DOIUrl":null,"url":null,"abstract":"The double insulation topic has become a very important issue in the satellite design since its implementation drives the sizing of the whole satellite electrical architecture. Different approaches and solutions have been proposed by Industry [2], according to specific need of each spacecraft design and requirements. According to ECSS-E-ST-20C [1]., a barrier against short circuit between conductors or circuit elements shall be guaranteed also after any credible single failure. In particular., the guideline is that all non-protected elements of a main bus distribution system shall implement an electrical double insulation up to the first protection device (e.g.: fuse., current breaker or current limiter).","PeriodicalId":6734,"journal":{"name":"2019 European Space Power Conference (ESPC)","volume":"20 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Implementation of double insulation at satellite level: an approach\",\"authors\":\"Mario Buffardo, E. Scione, Catalano Toni Fabio, Carlani Daniele, Ruà Emanuele Giovanni\",\"doi\":\"10.1109/ESPC.2019.8932082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The double insulation topic has become a very important issue in the satellite design since its implementation drives the sizing of the whole satellite electrical architecture. Different approaches and solutions have been proposed by Industry [2], according to specific need of each spacecraft design and requirements. According to ECSS-E-ST-20C [1]., a barrier against short circuit between conductors or circuit elements shall be guaranteed also after any credible single failure. In particular., the guideline is that all non-protected elements of a main bus distribution system shall implement an electrical double insulation up to the first protection device (e.g.: fuse., current breaker or current limiter).\",\"PeriodicalId\":6734,\"journal\":{\"name\":\"2019 European Space Power Conference (ESPC)\",\"volume\":\"20 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 European Space Power Conference (ESPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESPC.2019.8932082\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 European Space Power Conference (ESPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESPC.2019.8932082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Implementation of double insulation at satellite level: an approach
The double insulation topic has become a very important issue in the satellite design since its implementation drives the sizing of the whole satellite electrical architecture. Different approaches and solutions have been proposed by Industry [2], according to specific need of each spacecraft design and requirements. According to ECSS-E-ST-20C [1]., a barrier against short circuit between conductors or circuit elements shall be guaranteed also after any credible single failure. In particular., the guideline is that all non-protected elements of a main bus distribution system shall implement an electrical double insulation up to the first protection device (e.g.: fuse., current breaker or current limiter).