{"title":"护理点测试国际标准化比率:它们对监测血栓中心的维生素K拮抗剂有用吗?","authors":"D. Barcellona, L. Fenu, F. Marongiu","doi":"10.1097/POC.0000000000000159","DOIUrl":null,"url":null,"abstract":"Abstract Point of care testing (POCT) international normalized ratio (INR) devices are widely accepted for self-testing and self-management of vitamin K antagonists (VKAs). The aim of this work was to evaluate the performance of a POCT at our thrombosis centre aiming at reducing the time spent by patients for blood sampling and dose adjustment. A total of 101 consecutive oral anticoagulated patients (53 M, 48 F, median age 74 years, 23–89) were enrolled in the study that consisted of 2 different phases. In the first, standard monitoring was carried out for 3 months; during this period, the INR value was also determined by capillary blood sample with the use of a POCT to compare the INR values obtained with the two systems. In the second phase, patients were monitored for 3 months using only the CoaguChek XS Plus. The Bland-Altman test showed a good agreement between INR values obtained with the automated coagulometer and the CoaguChek XS Plus. The Passing and Bablok test showed no significant deviation from linearity. The total median waiting time was 3 hours and 45 minutes (from 0:44 to 6:05) and 1 hour and 16 minutes (P < 0.001) during standard monitoring and the use of the CoaguChek XS Plus, respectively. CoaguChek XS Plus is a suitable POCT for monitoring VKA therapy at a thrombosis centre, thus significantly reducing the time spent by patients for blood sampling and waiting for dosage adjustment.","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Points of Care Testing International Normalized Ratio: Are They Useful for Monitoring Vitamin K Antagonists in a Thrombosis Center?\",\"authors\":\"D. Barcellona, L. Fenu, F. Marongiu\",\"doi\":\"10.1097/POC.0000000000000159\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Point of care testing (POCT) international normalized ratio (INR) devices are widely accepted for self-testing and self-management of vitamin K antagonists (VKAs). The aim of this work was to evaluate the performance of a POCT at our thrombosis centre aiming at reducing the time spent by patients for blood sampling and dose adjustment. A total of 101 consecutive oral anticoagulated patients (53 M, 48 F, median age 74 years, 23–89) were enrolled in the study that consisted of 2 different phases. In the first, standard monitoring was carried out for 3 months; during this period, the INR value was also determined by capillary blood sample with the use of a POCT to compare the INR values obtained with the two systems. In the second phase, patients were monitored for 3 months using only the CoaguChek XS Plus. The Bland-Altman test showed a good agreement between INR values obtained with the automated coagulometer and the CoaguChek XS Plus. The Passing and Bablok test showed no significant deviation from linearity. The total median waiting time was 3 hours and 45 minutes (from 0:44 to 6:05) and 1 hour and 16 minutes (P < 0.001) during standard monitoring and the use of the CoaguChek XS Plus, respectively. CoaguChek XS Plus is a suitable POCT for monitoring VKA therapy at a thrombosis centre, thus significantly reducing the time spent by patients for blood sampling and waiting for dosage adjustment.\",\"PeriodicalId\":20262,\"journal\":{\"name\":\"Point of Care: The Journal of Near-Patient Testing & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Point of Care: The Journal of Near-Patient Testing & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/POC.0000000000000159\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

护理点检测(POCT)国际归一化比率(INR)装置被广泛接受用于维生素K拮抗剂(vka)的自我检测和自我管理。这项工作的目的是评估POCT在我们血栓中心的性能,旨在减少患者用于血液采样和剂量调整的时间。共有101例连续口服抗凝患者(53例M, 48例F,中位年龄74岁,23-89岁)纳入研究,研究分为2个不同的阶段。第一阶段进行3个月的标准监测;在此期间,还通过毛细管血液样本测定INR值,并使用POCT比较两种系统获得的INR值。在第二阶段,仅使用CoaguChek XS Plus对患者进行3个月的监测。Bland-Altman试验表明,自动凝血仪和CoaguChek XS Plus获得的INR值吻合良好。通过和Bablok检验显示线性无显著偏差。在标准监测和使用CoaguChek XS Plus期间,总中位等待时间分别为3小时45分钟(0:44至6:05)和1小时16分钟(P < 0.001)。CoaguChek XS Plus是一种适合在血栓中心监测VKA治疗的POCT,从而大大减少了患者采血和等待剂量调整的时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Points of Care Testing International Normalized Ratio: Are They Useful for Monitoring Vitamin K Antagonists in a Thrombosis Center?
Abstract Point of care testing (POCT) international normalized ratio (INR) devices are widely accepted for self-testing and self-management of vitamin K antagonists (VKAs). The aim of this work was to evaluate the performance of a POCT at our thrombosis centre aiming at reducing the time spent by patients for blood sampling and dose adjustment. A total of 101 consecutive oral anticoagulated patients (53 M, 48 F, median age 74 years, 23–89) were enrolled in the study that consisted of 2 different phases. In the first, standard monitoring was carried out for 3 months; during this period, the INR value was also determined by capillary blood sample with the use of a POCT to compare the INR values obtained with the two systems. In the second phase, patients were monitored for 3 months using only the CoaguChek XS Plus. The Bland-Altman test showed a good agreement between INR values obtained with the automated coagulometer and the CoaguChek XS Plus. The Passing and Bablok test showed no significant deviation from linearity. The total median waiting time was 3 hours and 45 minutes (from 0:44 to 6:05) and 1 hour and 16 minutes (P < 0.001) during standard monitoring and the use of the CoaguChek XS Plus, respectively. CoaguChek XS Plus is a suitable POCT for monitoring VKA therapy at a thrombosis centre, thus significantly reducing the time spent by patients for blood sampling and waiting for dosage adjustment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin Critical Care Nurses' Views and Experiences of Preanalytical Factors Influencing Point-of-Care Testing Rapid Assessment of Coagulation at the Point of Care With the Hemochron Signature Elite System Invited Product Profile: Detecting Antibodies for Lyme Disease at the Point of Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1