{"title":"电力地下电缆分布式局部放电测量","authors":"V. R. Garcia-Colon","doi":"10.1109/ELINSL.2002.995880","DOIUrl":null,"url":null,"abstract":"In this paper a multi point partial discharge (PD) measurement approach is presented and named as distributed PD measurement (D-PDM). These D-PDM technique records PD pulses using an ultra wide band system that allow spatial discrimination due to high frequency signals rapid decay while displaying the output in a traditional Q-F-N pattern to facilitate problem identification. D-PDM was applied to evaluate an underground radial and meshed distribution networks with over 70 three phase PILC circuits while in normal operation. Several incipient fault sites were located and a predictive maintenance program established using this technique.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"5 1","pages":"57-61"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Distributed PD measurement on power underground cables\",\"authors\":\"V. R. Garcia-Colon\",\"doi\":\"10.1109/ELINSL.2002.995880\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a multi point partial discharge (PD) measurement approach is presented and named as distributed PD measurement (D-PDM). These D-PDM technique records PD pulses using an ultra wide band system that allow spatial discrimination due to high frequency signals rapid decay while displaying the output in a traditional Q-F-N pattern to facilitate problem identification. D-PDM was applied to evaluate an underground radial and meshed distribution networks with over 70 three phase PILC circuits while in normal operation. Several incipient fault sites were located and a predictive maintenance program established using this technique.\",\"PeriodicalId\":10532,\"journal\":{\"name\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"volume\":\"5 1\",\"pages\":\"57-61\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2002.995880\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种多点局部放电测量方法,称为分布式局部放电测量(D-PDM)。这些D-PDM技术使用超宽带系统记录PD脉冲,由于高频信号快速衰减,该系统允许空间辨别,同时以传统的Q-F-N模式显示输出,以方便问题识别。应用D-PDM对70余条三相PILC线路的地下径向和网状配电网进行了正常运行评价。利用该技术确定了几个早期故障点,并建立了预测性维护计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Distributed PD measurement on power underground cables
In this paper a multi point partial discharge (PD) measurement approach is presented and named as distributed PD measurement (D-PDM). These D-PDM technique records PD pulses using an ultra wide band system that allow spatial discrimination due to high frequency signals rapid decay while displaying the output in a traditional Q-F-N pattern to facilitate problem identification. D-PDM was applied to evaluate an underground radial and meshed distribution networks with over 70 three phase PILC circuits while in normal operation. Several incipient fault sites were located and a predictive maintenance program established using this technique.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
After-installation test of HV extruded cable insulation Experimental investigation into the thermal-ageing of Kraft paper and mineral insulating oil Enhanced online PD evaluation on power transformers using wavelet techniques and frequency rejection filter for noise suppression On-line PD detection, requirements for practical use PD site location in distribution power cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1