长持续电流云对地闪电对500kv直流输电线路运行特性的影响

Peng Li, Pan Xiao, Tian Wu, Ziheng Pu, Chunhua Fang, Yu Wang
{"title":"长持续电流云对地闪电对500kv直流输电线路运行特性的影响","authors":"Peng Li, Pan Xiao, Tian Wu, Ziheng Pu, Chunhua Fang, Yu Wang","doi":"10.1109/ICHVE49031.2020.9280067","DOIUrl":null,"url":null,"abstract":"The operating experience of power transmission lines shows that the influence of the continuous current process after cloud-to-ground (C-G) lightning return-stroke on the DC line cannot be ignored. Therefore, the characteristics of the continuous current are analyzed statistically in this paper. The lightning overvoltage simulation model considering the long continuous current is built, and the influence of the long continuing current on the operation characteristic of 500 kV DC transmission line is analyzed by simulation. Simulation results indicate that the long continuous current has less effect on the overvoltage amplitude of the transmission line. But after the lightning causes the insulator flashover, the flashover current of the insulator is increased by about 47% of the continuous current amplitude. When the arrester is in normal operation, the energy absorption is mainly determined by the stage of the return-stroke, and the existence of continuous current has almost no influence. However, when multiple return-strokes cause the arrester to fail, the influence of the continuous current needs to be considered.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"49 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of Cloud-to-Ground Lightning with long Continuing Current on the Operation Characteristic of 500 kV DC Transmission Line\",\"authors\":\"Peng Li, Pan Xiao, Tian Wu, Ziheng Pu, Chunhua Fang, Yu Wang\",\"doi\":\"10.1109/ICHVE49031.2020.9280067\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The operating experience of power transmission lines shows that the influence of the continuous current process after cloud-to-ground (C-G) lightning return-stroke on the DC line cannot be ignored. Therefore, the characteristics of the continuous current are analyzed statistically in this paper. The lightning overvoltage simulation model considering the long continuous current is built, and the influence of the long continuing current on the operation characteristic of 500 kV DC transmission line is analyzed by simulation. Simulation results indicate that the long continuous current has less effect on the overvoltage amplitude of the transmission line. But after the lightning causes the insulator flashover, the flashover current of the insulator is increased by about 47% of the continuous current amplitude. When the arrester is in normal operation, the energy absorption is mainly determined by the stage of the return-stroke, and the existence of continuous current has almost no influence. However, when multiple return-strokes cause the arrester to fail, the influence of the continuous current needs to be considered.\",\"PeriodicalId\":6763,\"journal\":{\"name\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"volume\":\"49 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE49031.2020.9280067\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9280067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

输电线路的运行经验表明,云对地雷电回击后的连续电流过程对直流线路的影响是不可忽视的。因此,本文对连续电流的特性进行了统计分析。建立了考虑长连续电流的雷电过电压仿真模型,通过仿真分析了长连续电流对500kv直流输电线路运行特性的影响。仿真结果表明,长时间连续电流对输电线路过电压幅值的影响较小。但雷电引起绝缘子闪络后,绝缘子的闪络电流增加约为连续电流幅值的47%。当避雷器正常工作时,能量吸收主要由回程行程的阶段决定,连续电流的存在几乎没有影响。然而,当多次回击导致避雷器失效时,需要考虑连续电流的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Cloud-to-Ground Lightning with long Continuing Current on the Operation Characteristic of 500 kV DC Transmission Line
The operating experience of power transmission lines shows that the influence of the continuous current process after cloud-to-ground (C-G) lightning return-stroke on the DC line cannot be ignored. Therefore, the characteristics of the continuous current are analyzed statistically in this paper. The lightning overvoltage simulation model considering the long continuous current is built, and the influence of the long continuing current on the operation characteristic of 500 kV DC transmission line is analyzed by simulation. Simulation results indicate that the long continuous current has less effect on the overvoltage amplitude of the transmission line. But after the lightning causes the insulator flashover, the flashover current of the insulator is increased by about 47% of the continuous current amplitude. When the arrester is in normal operation, the energy absorption is mainly determined by the stage of the return-stroke, and the existence of continuous current has almost no influence. However, when multiple return-strokes cause the arrester to fail, the influence of the continuous current needs to be considered.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Excellent electrical properties of zinc-oxide varistors by tailoring sintering process for optimizing line-arrester configuration Research of Short Air Gap Flashover Characteristic with Water Droplets Pattern Recognition of Development Stage of Creepage Discharge of Oil-Paper Insulation under AC-DC Combined Voltage based on OS-ELM Study on the PD Creeping Discharge Development Process Induced by Metallic Particles in GIS A Novel Fabry-Perot Sensor Mounted on External Surface of Transformers for Partial Discharge Detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1