{"title":"利用真空驱动系统和激光扫描仪进行高效免疫印迹的研究化学发光与免疫荧光成像两种信号检测方法的比较","authors":"Chisato Harada, H. Tajima, S. Hirohashi, T. Kondo","doi":"10.2198/JELECTROPH.53.63","DOIUrl":null,"url":null,"abstract":"A vacuum-driven antibody-reaction system enables high-throughput western blotting, where the antibodies pass through protein-transferred membrane and antibody-antigen reaction is completed within 30 min. With the vacuum-based device, two protein detection methods compatible with by laser scanning were compared; one with enhanced chemiluminescence reaction and the other using fluorescence-labeled antibody. Considering sensitivity, quantitative capability, reproducibility and labor intensiveness, we concluded that fluorescence-based detection is more suitable in combination with the vacuum-driven antibody-reaction system and a laser scanner.","PeriodicalId":15059,"journal":{"name":"Journal of capillary electrophoresis","volume":"8 1","pages":"63-66"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Toward high performance western blotting using vacuum-driven system and laser scanner; comparison between two signal detection methods based on chemiluminescent and immunofluorescent imaging\",\"authors\":\"Chisato Harada, H. Tajima, S. Hirohashi, T. Kondo\",\"doi\":\"10.2198/JELECTROPH.53.63\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A vacuum-driven antibody-reaction system enables high-throughput western blotting, where the antibodies pass through protein-transferred membrane and antibody-antigen reaction is completed within 30 min. With the vacuum-based device, two protein detection methods compatible with by laser scanning were compared; one with enhanced chemiluminescence reaction and the other using fluorescence-labeled antibody. Considering sensitivity, quantitative capability, reproducibility and labor intensiveness, we concluded that fluorescence-based detection is more suitable in combination with the vacuum-driven antibody-reaction system and a laser scanner.\",\"PeriodicalId\":15059,\"journal\":{\"name\":\"Journal of capillary electrophoresis\",\"volume\":\"8 1\",\"pages\":\"63-66\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of capillary electrophoresis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2198/JELECTROPH.53.63\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of capillary electrophoresis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2198/JELECTROPH.53.63","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Toward high performance western blotting using vacuum-driven system and laser scanner; comparison between two signal detection methods based on chemiluminescent and immunofluorescent imaging
A vacuum-driven antibody-reaction system enables high-throughput western blotting, where the antibodies pass through protein-transferred membrane and antibody-antigen reaction is completed within 30 min. With the vacuum-based device, two protein detection methods compatible with by laser scanning were compared; one with enhanced chemiluminescence reaction and the other using fluorescence-labeled antibody. Considering sensitivity, quantitative capability, reproducibility and labor intensiveness, we concluded that fluorescence-based detection is more suitable in combination with the vacuum-driven antibody-reaction system and a laser scanner.