{"title":"湿喷混凝土可喷涂性研究进展","authors":"Nicholas Trussell, S. Jacobsen","doi":"10.2478/ncr-2020-0016","DOIUrl":null,"url":null,"abstract":"Abstract Wet sprayed concrete quality is affected by more production factors than cast concrete, particularly due to the propulsion through the nozzle and the flash set caused by the set accelerator. Practitioners often use the term “sprayability” to describe these factors. We propose a definition of “sprayability” that relates the application to the final properties of the hardened sprayed concrete and review factors affecting it: concrete constituents, proportioning, and application mechanics. These factors affect the hardening and the structure of the hardened sprayed concrete – the porosity, permeability and durability. We consider improving sustainability through proportioning with increased share of supplementary cementitious materials, calculate the placed composition and focus on factors that affect water transport, and hence durability. Due to the spray application and flash-set, irregular compaction voids dominate the macro pore structure of sprayed concrete. Studies of permeability of sprayed concrete have shown that it is possible to obtain low permeabilities given adequate composition and curing. Presumably these samples have been well-cured, uncracked and with non-percolating macro voids. Given observations of cracks in sprayed concrete linings and the macro voids, important further studies will be on the effect of accelerator, compaction porosity and cracking on permeability.","PeriodicalId":42762,"journal":{"name":"Nordic Concrete Research","volume":"63 1","pages":"21 - 41"},"PeriodicalIF":0.7000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Review of Sprayability of Wet Sprayed Concrete\",\"authors\":\"Nicholas Trussell, S. Jacobsen\",\"doi\":\"10.2478/ncr-2020-0016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Wet sprayed concrete quality is affected by more production factors than cast concrete, particularly due to the propulsion through the nozzle and the flash set caused by the set accelerator. Practitioners often use the term “sprayability” to describe these factors. We propose a definition of “sprayability” that relates the application to the final properties of the hardened sprayed concrete and review factors affecting it: concrete constituents, proportioning, and application mechanics. These factors affect the hardening and the structure of the hardened sprayed concrete – the porosity, permeability and durability. We consider improving sustainability through proportioning with increased share of supplementary cementitious materials, calculate the placed composition and focus on factors that affect water transport, and hence durability. Due to the spray application and flash-set, irregular compaction voids dominate the macro pore structure of sprayed concrete. Studies of permeability of sprayed concrete have shown that it is possible to obtain low permeabilities given adequate composition and curing. Presumably these samples have been well-cured, uncracked and with non-percolating macro voids. Given observations of cracks in sprayed concrete linings and the macro voids, important further studies will be on the effect of accelerator, compaction porosity and cracking on permeability.\",\"PeriodicalId\":42762,\"journal\":{\"name\":\"Nordic Concrete Research\",\"volume\":\"63 1\",\"pages\":\"21 - 41\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2020-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nordic Concrete Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ncr-2020-0016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nordic Concrete Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ncr-2020-0016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 5

摘要

影响湿喷混凝土质量的生产因素比现浇混凝土多,特别是受喷管推进和凝结加速剂产生的闪集等因素的影响。从业者经常使用术语“可喷涂性”来描述这些因素。我们提出了一个“可喷涂性”的定义,它与硬化喷射混凝土的最终性能有关,并回顾了影响它的因素:混凝土成分、比例和应用力学。这些因素影响着硬化后喷射混凝土的硬化和结构——孔隙率、渗透性和耐久性。我们考虑通过增加补充胶凝材料的比例来提高可持续性,计算放置的成分,并关注影响水运的因素,从而提高耐久性。由于喷淋和闪凝作用,不规则的压实空隙主导着喷淋混凝土的宏观孔隙结构。对喷射混凝土渗透性的研究表明,在适当的成分和养护下,获得低渗透性是可能的。据推测,这些样品已经很好地固化了,没有开裂,没有渗透的宏观空隙。在观察到喷射混凝土衬砌裂缝和宏观空隙的情况下,进一步研究促进剂、压实孔隙率和裂缝对渗透性能的影响将是重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Review of Sprayability of Wet Sprayed Concrete
Abstract Wet sprayed concrete quality is affected by more production factors than cast concrete, particularly due to the propulsion through the nozzle and the flash set caused by the set accelerator. Practitioners often use the term “sprayability” to describe these factors. We propose a definition of “sprayability” that relates the application to the final properties of the hardened sprayed concrete and review factors affecting it: concrete constituents, proportioning, and application mechanics. These factors affect the hardening and the structure of the hardened sprayed concrete – the porosity, permeability and durability. We consider improving sustainability through proportioning with increased share of supplementary cementitious materials, calculate the placed composition and focus on factors that affect water transport, and hence durability. Due to the spray application and flash-set, irregular compaction voids dominate the macro pore structure of sprayed concrete. Studies of permeability of sprayed concrete have shown that it is possible to obtain low permeabilities given adequate composition and curing. Presumably these samples have been well-cured, uncracked and with non-percolating macro voids. Given observations of cracks in sprayed concrete linings and the macro voids, important further studies will be on the effect of accelerator, compaction porosity and cracking on permeability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nordic Concrete Research
Nordic Concrete Research CONSTRUCTION & BUILDING TECHNOLOGY-
自引率
20.00%
发文量
8
期刊最新文献
Load Effects of ASR-induced Expansion in Reinforced Concrete and Their Consequences for Structural Assessment A Review on Fatigue Performance of Concrete Structures Part II, Material Parameters and Environmental Factors Chloride Ion Diffusion Resistance of Bulk Hydrophobic Concrete: Comparison of w/c and Dosages Requirements for Test Series for Relative Humidity Measurements to Calibrate Drying Time Simulation Model Assessment of Effective and Minimal Slab Widths for Evaluating the Shear Capacity of RC Overhang Slabs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1