一些测量仪器中性浮子

T.E. Pochapsky
{"title":"一些测量仪器中性浮子","authors":"T.E. Pochapsky","doi":"10.1016/0146-6313(61)90028-4","DOIUrl":null,"url":null,"abstract":"<div><p>The motions of instrumented neutral floats were measured during short tests at various locations in the North Atlantic Ocean. The vertical paths as a function of time were obtained for floats from the time they were placed in the water until well after they reached their equilibrium levels. Motions attributed to internal waves were observed on sensitively instrumented near-surface floats. Pairs of floats were found to separate rapidly with a speed which was not constant.</p><p>A pressure-gradient measuring device showed no fluctuations over a length of approximately 100 cm at depths from 200 to 700 m. The static sensitivity of the equipment was approximately 3 dyne cm<sup>−2</sup> mm<sup>−1</sup>. Response of the device in shallower water was probably caused by gravity waves.</p></div>","PeriodicalId":100361,"journal":{"name":"Deep Sea Research (1953)","volume":"8 3","pages":"Pages 269-279"},"PeriodicalIF":0.0000,"publicationDate":"1961-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0146-6313(61)90028-4","citationCount":"3","resultStr":"{\"title\":\"Some measurements with instrumented neutral floats\",\"authors\":\"T.E. Pochapsky\",\"doi\":\"10.1016/0146-6313(61)90028-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The motions of instrumented neutral floats were measured during short tests at various locations in the North Atlantic Ocean. The vertical paths as a function of time were obtained for floats from the time they were placed in the water until well after they reached their equilibrium levels. Motions attributed to internal waves were observed on sensitively instrumented near-surface floats. Pairs of floats were found to separate rapidly with a speed which was not constant.</p><p>A pressure-gradient measuring device showed no fluctuations over a length of approximately 100 cm at depths from 200 to 700 m. The static sensitivity of the equipment was approximately 3 dyne cm<sup>−2</sup> mm<sup>−1</sup>. Response of the device in shallower water was probably caused by gravity waves.</p></div>\",\"PeriodicalId\":100361,\"journal\":{\"name\":\"Deep Sea Research (1953)\",\"volume\":\"8 3\",\"pages\":\"Pages 269-279\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1961-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0146-6313(61)90028-4\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deep Sea Research (1953)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0146631361900284\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deep Sea Research (1953)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0146631361900284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在北大西洋不同地点进行的短期试验中,测量了仪表中性浮子的运动。从漂浮物被放入水中直到漂浮物达到平衡水平,得到了漂浮物随时间变化的垂直路径。由内波引起的运动在装有灵敏仪器的近水面浮子上被观测到。研究发现,浮子成对分离的速度不是恒定的。压力梯度测量装置显示,在200至700米的深度,在大约100厘米的长度范围内没有波动。设备的静态灵敏度约为3达因cm−2 mm−1。该装置在浅水中的响应可能是由重力波引起的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Some measurements with instrumented neutral floats

The motions of instrumented neutral floats were measured during short tests at various locations in the North Atlantic Ocean. The vertical paths as a function of time were obtained for floats from the time they were placed in the water until well after they reached their equilibrium levels. Motions attributed to internal waves were observed on sensitively instrumented near-surface floats. Pairs of floats were found to separate rapidly with a speed which was not constant.

A pressure-gradient measuring device showed no fluctuations over a length of approximately 100 cm at depths from 200 to 700 m. The static sensitivity of the equipment was approximately 3 dyne cm−2 mm−1. Response of the device in shallower water was probably caused by gravity waves.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correction Further considerations regarding the antiquity of the abyssal fauna with evidence for a changing abyssal environment Prevention of water loss through CAB plastic sediment core liners A contribution to the problem of the Drake Passage circulation Erratic boulders from great meteor seamount
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1