Ç. Deniz, Vildan Güzel, Gulistan Halac, Muharrem Nasifov, Ömer Göktekin, Talip Asil
{"title":"Karotid Arter Darlık Oranı ile Perioperatif Stent Komplikasyonları İlişkisi","authors":"Ç. Deniz, Vildan Güzel, Gulistan Halac, Muharrem Nasifov, Ömer Göktekin, Talip Asil","doi":"10.31832/smj.1130202","DOIUrl":null,"url":null,"abstract":"Objective: This study aimed to examine complications that may occur after carotid artery stenting (CAS) and their relationships with carotid artery stenosis rate. \nMaterials and Methods: Complications, such as cerebral hyperperfusion, stroke, death, stent thrombosis or occlusion and restenosis, were evaluated on the 30th day after CAS and at the end of the first year. \nResults: Of the 205 CAS procedures, complications developed in 12 patients. The complication rate for the first 30 days after the procedure was 4,87%, and at the end of the first year, it was 5,85%. Of the 12 patients with complications, 8 had carotid stenosis of ≥90%. Death occurred in 4 of 195 patients with carotid artery stenosis. The mortality rate within the first 30 days and during the 1-year follow-up period was 1,53% and 2,05%, respectively. Ischemic stroke occurred in 6 of 195 patients with carotid artery stenosis. After the first 30 days and one year follow-up, ischemic stroke had occurred in 3,07% of patients. Stent thrombosis and occlusion rate was 4,87% in 205 CAS procedures, and 7 of them occurred in the first 24 hours and another 3 occurred within the first 30 days. Restenosis rates were 0,48% and 0,97% at 6 months and the first year, respectively. \nConclusion: The complications of CAS have been associated with the urgency of treatment (emergency), symptom presence (symptomatic patients) and high degree of stenosis (≥90%); whereas bilateral stenosis is not associated with complications. In addition, stent thrombosis and occlusion were observed as the most common CAS complication.","PeriodicalId":21405,"journal":{"name":"Sakarya Medical Journal","volume":"44 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sakarya Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31832/smj.1130202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Karotid Arter Darlık Oranı ile Perioperatif Stent Komplikasyonları İlişkisi
Objective: This study aimed to examine complications that may occur after carotid artery stenting (CAS) and their relationships with carotid artery stenosis rate.
Materials and Methods: Complications, such as cerebral hyperperfusion, stroke, death, stent thrombosis or occlusion and restenosis, were evaluated on the 30th day after CAS and at the end of the first year.
Results: Of the 205 CAS procedures, complications developed in 12 patients. The complication rate for the first 30 days after the procedure was 4,87%, and at the end of the first year, it was 5,85%. Of the 12 patients with complications, 8 had carotid stenosis of ≥90%. Death occurred in 4 of 195 patients with carotid artery stenosis. The mortality rate within the first 30 days and during the 1-year follow-up period was 1,53% and 2,05%, respectively. Ischemic stroke occurred in 6 of 195 patients with carotid artery stenosis. After the first 30 days and one year follow-up, ischemic stroke had occurred in 3,07% of patients. Stent thrombosis and occlusion rate was 4,87% in 205 CAS procedures, and 7 of them occurred in the first 24 hours and another 3 occurred within the first 30 days. Restenosis rates were 0,48% and 0,97% at 6 months and the first year, respectively.
Conclusion: The complications of CAS have been associated with the urgency of treatment (emergency), symptom presence (symptomatic patients) and high degree of stenosis (≥90%); whereas bilateral stenosis is not associated with complications. In addition, stent thrombosis and occlusion were observed as the most common CAS complication.