{"title":"炎热干旱气候下教育建筑室内环境质量的回归模型预测——以伊拉克Al-Najaf技术学院为例","authors":"Rawaa H. K. Al-Isawi, H. A. Al-Zubaidi, I. Idan, M. Scholz","doi":"10.5755/j01.erem.78.1.29597","DOIUrl":null,"url":null,"abstract":"In hot climates, achieving a good indoor environmental quality (IEQ) in existing buildings is important especially with climate change challenges as future heat waves will increase in frequency, duration, and intensity. In educational buildings, there is much more focus on the IEQ parameters and the interactions among them that need to be in line with the continuously changing learning environment. This study assesses the IEQ parameters (represented by noise, temperature and humidity) at three selected campus areas (lecture rooms of an administrative department building (LR), main hall of a management department building (MH) and a central library building (CL)) at the Al-Najaf Technical Institute (NTI), Al-Najaf City, Iraq, for the period from May to December 2019. A statistical analysis using a multi-linear regression model was performed to determine the relationship between the selected IEQ parameters and explain the noise level behavior as a function of the temperature and relative humidity. The research indicated that the noise levels and temperature values exceeded the maximum standard limits in all buildings reflecting the displeasing sound and heating quality within the studied areas, while the readings for relative humidity within each building environment complied with standards. Moreover, for both LR and MH buildings (R2 ≥ 0.8, significance F ≤ 0.01), the noise values were satisfactorily modeled by temperature and relative humidity highlighting the interactions between temperature, humidity and noise under consistent conditions. However, the results for the CL building (R2 = 0.6, significance F = 0.1) showed no relationship between the IEQ parameters, highlighting the fact that this building is exposed to unsteady conditions (an irregular number of people using this building during the daytime) resulting in a high variation of data measurements. The current results demonstrate that detailed modeling can be helpful to predict IEQ parameters depending on other known parameters in buildings. The results of the predictive model aligned with the directly measured data. Therefore, its performance is equally effective, but with a significant reduction in cost and time consumed.","PeriodicalId":11703,"journal":{"name":"Environmental Research, Engineering and Management","volume":"18 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prediction of Indoor Environmental Quality Using a Regression Model for Educational Buildings in Hot Arid Climate: A Case Study in the Al-Najaf Technical Institute – Iraq\",\"authors\":\"Rawaa H. K. Al-Isawi, H. A. Al-Zubaidi, I. Idan, M. Scholz\",\"doi\":\"10.5755/j01.erem.78.1.29597\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In hot climates, achieving a good indoor environmental quality (IEQ) in existing buildings is important especially with climate change challenges as future heat waves will increase in frequency, duration, and intensity. In educational buildings, there is much more focus on the IEQ parameters and the interactions among them that need to be in line with the continuously changing learning environment. This study assesses the IEQ parameters (represented by noise, temperature and humidity) at three selected campus areas (lecture rooms of an administrative department building (LR), main hall of a management department building (MH) and a central library building (CL)) at the Al-Najaf Technical Institute (NTI), Al-Najaf City, Iraq, for the period from May to December 2019. A statistical analysis using a multi-linear regression model was performed to determine the relationship between the selected IEQ parameters and explain the noise level behavior as a function of the temperature and relative humidity. The research indicated that the noise levels and temperature values exceeded the maximum standard limits in all buildings reflecting the displeasing sound and heating quality within the studied areas, while the readings for relative humidity within each building environment complied with standards. Moreover, for both LR and MH buildings (R2 ≥ 0.8, significance F ≤ 0.01), the noise values were satisfactorily modeled by temperature and relative humidity highlighting the interactions between temperature, humidity and noise under consistent conditions. However, the results for the CL building (R2 = 0.6, significance F = 0.1) showed no relationship between the IEQ parameters, highlighting the fact that this building is exposed to unsteady conditions (an irregular number of people using this building during the daytime) resulting in a high variation of data measurements. The current results demonstrate that detailed modeling can be helpful to predict IEQ parameters depending on other known parameters in buildings. The results of the predictive model aligned with the directly measured data. Therefore, its performance is equally effective, but with a significant reduction in cost and time consumed.\",\"PeriodicalId\":11703,\"journal\":{\"name\":\"Environmental Research, Engineering and Management\",\"volume\":\"18 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Research, Engineering and Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5755/j01.erem.78.1.29597\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Research, Engineering and Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5755/j01.erem.78.1.29597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
Prediction of Indoor Environmental Quality Using a Regression Model for Educational Buildings in Hot Arid Climate: A Case Study in the Al-Najaf Technical Institute – Iraq
In hot climates, achieving a good indoor environmental quality (IEQ) in existing buildings is important especially with climate change challenges as future heat waves will increase in frequency, duration, and intensity. In educational buildings, there is much more focus on the IEQ parameters and the interactions among them that need to be in line with the continuously changing learning environment. This study assesses the IEQ parameters (represented by noise, temperature and humidity) at three selected campus areas (lecture rooms of an administrative department building (LR), main hall of a management department building (MH) and a central library building (CL)) at the Al-Najaf Technical Institute (NTI), Al-Najaf City, Iraq, for the period from May to December 2019. A statistical analysis using a multi-linear regression model was performed to determine the relationship between the selected IEQ parameters and explain the noise level behavior as a function of the temperature and relative humidity. The research indicated that the noise levels and temperature values exceeded the maximum standard limits in all buildings reflecting the displeasing sound and heating quality within the studied areas, while the readings for relative humidity within each building environment complied with standards. Moreover, for both LR and MH buildings (R2 ≥ 0.8, significance F ≤ 0.01), the noise values were satisfactorily modeled by temperature and relative humidity highlighting the interactions between temperature, humidity and noise under consistent conditions. However, the results for the CL building (R2 = 0.6, significance F = 0.1) showed no relationship between the IEQ parameters, highlighting the fact that this building is exposed to unsteady conditions (an irregular number of people using this building during the daytime) resulting in a high variation of data measurements. The current results demonstrate that detailed modeling can be helpful to predict IEQ parameters depending on other known parameters in buildings. The results of the predictive model aligned with the directly measured data. Therefore, its performance is equally effective, but with a significant reduction in cost and time consumed.
期刊介绍:
First published in 1995, the journal Environmental Research, Engineering and Management (EREM) is an international multidisciplinary journal designed to serve as a roadmap for understanding complex issues and debates of sustainable development. EREM publishes peer-reviewed scientific papers which cover research in the fields of environmental science, engineering (pollution prevention, resource efficiency), management, energy (renewables), agricultural and biological sciences, and social sciences. EREM’s topics of interest include, but are not limited to, the following: environmental research, ecological monitoring, and climate change; environmental pollution – impact assessment, mitigation, and prevention; environmental engineering, sustainable production, and eco innovations; environmental management, strategy, standards, social responsibility; environmental economics, policy, and law; sustainable consumption and education.