{"title":"非调制睡眠基多频带信号的模拟压缩感知","authors":"Xianjun Yang, E. Dutkiewicz, Qimei Cui, Xiaojing Huang, Xiaofeng Tao, Gengfa Fang","doi":"10.1109/ICC.2013.6655361","DOIUrl":null,"url":null,"abstract":"Recently, the recovery performance of analog Compressed Sensing (CS) has been significantly improved by representing multiband signals with the modulated and merged Slepian basis (MM-Slepian dictionary), which avoids the frequency leakage effect of the Discrete Fourier Transform (DFT) basis. However, the MM-Slepian dictionary has a very large scale and corresponds to a large-scale measurement matrix, which leads to high recovery computational complexity. This paper resolves the above problem by modulating and band-limiting the multiband signal rather than modulating the Slepian basis. Specifically, instead of using the MM-Slepian dictionary to represent the whole multiband signal, we propose to use the non-modulated Slepian basis to represent the modulated and band-limited version of the multiband signal based on the recently proposed Modulated Wideband Converter (MWC). Furthermore, based on the analytical derivation with the non-modulated Slepian basis, we propose an Interpolation Recovery (IR) algorithm to take full advantage of the Slepian basis, whereas the Direct Recovery (DR) algorithm using the Moore-Penrose pseudo-inverse cannot achieve this. Simulation results verify that, with low recovery computational load, the non-modulated Slepian basis combined with the IR algorithm improves the recovery SNR by up to 35 dB compared with the DFT basis in noise-free environment.","PeriodicalId":6368,"journal":{"name":"2013 IEEE International Conference on Communications (ICC)","volume":"89 1","pages":"4941-4945"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analog compressed sensing for multiband signals with non-modulated Slepian basis\",\"authors\":\"Xianjun Yang, E. Dutkiewicz, Qimei Cui, Xiaojing Huang, Xiaofeng Tao, Gengfa Fang\",\"doi\":\"10.1109/ICC.2013.6655361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, the recovery performance of analog Compressed Sensing (CS) has been significantly improved by representing multiband signals with the modulated and merged Slepian basis (MM-Slepian dictionary), which avoids the frequency leakage effect of the Discrete Fourier Transform (DFT) basis. However, the MM-Slepian dictionary has a very large scale and corresponds to a large-scale measurement matrix, which leads to high recovery computational complexity. This paper resolves the above problem by modulating and band-limiting the multiband signal rather than modulating the Slepian basis. Specifically, instead of using the MM-Slepian dictionary to represent the whole multiband signal, we propose to use the non-modulated Slepian basis to represent the modulated and band-limited version of the multiband signal based on the recently proposed Modulated Wideband Converter (MWC). Furthermore, based on the analytical derivation with the non-modulated Slepian basis, we propose an Interpolation Recovery (IR) algorithm to take full advantage of the Slepian basis, whereas the Direct Recovery (DR) algorithm using the Moore-Penrose pseudo-inverse cannot achieve this. Simulation results verify that, with low recovery computational load, the non-modulated Slepian basis combined with the IR algorithm improves the recovery SNR by up to 35 dB compared with the DFT basis in noise-free environment.\",\"PeriodicalId\":6368,\"journal\":{\"name\":\"2013 IEEE International Conference on Communications (ICC)\",\"volume\":\"89 1\",\"pages\":\"4941-4945\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Communications (ICC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICC.2013.6655361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Communications (ICC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICC.2013.6655361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analog compressed sensing for multiband signals with non-modulated Slepian basis
Recently, the recovery performance of analog Compressed Sensing (CS) has been significantly improved by representing multiband signals with the modulated and merged Slepian basis (MM-Slepian dictionary), which avoids the frequency leakage effect of the Discrete Fourier Transform (DFT) basis. However, the MM-Slepian dictionary has a very large scale and corresponds to a large-scale measurement matrix, which leads to high recovery computational complexity. This paper resolves the above problem by modulating and band-limiting the multiband signal rather than modulating the Slepian basis. Specifically, instead of using the MM-Slepian dictionary to represent the whole multiband signal, we propose to use the non-modulated Slepian basis to represent the modulated and band-limited version of the multiband signal based on the recently proposed Modulated Wideband Converter (MWC). Furthermore, based on the analytical derivation with the non-modulated Slepian basis, we propose an Interpolation Recovery (IR) algorithm to take full advantage of the Slepian basis, whereas the Direct Recovery (DR) algorithm using the Moore-Penrose pseudo-inverse cannot achieve this. Simulation results verify that, with low recovery computational load, the non-modulated Slepian basis combined with the IR algorithm improves the recovery SNR by up to 35 dB compared with the DFT basis in noise-free environment.