一种用于比约克-希利心脏瓣膜数字放射图像平移和旋转校正的自动时间对齐技术

E. Çesmeli, K. Powell, N. Greenberg, J. Cornhill
{"title":"一种用于比约克-希利心脏瓣膜数字放射图像平移和旋转校正的自动时间对齐技术","authors":"E. Çesmeli, K. Powell, N. Greenberg, J. Cornhill","doi":"10.1109/CIC.1993.378326","DOIUrl":null,"url":null,"abstract":"An accurate technique for the temporal registration of digital radiographic valve images is an integral process in the objective quantification of single leg separation (SLS) in Bjork-Shiley Convexo Concave heart valves. The authors have developed a fully automated technique for the translational and rotational correction of sequential valve images based on the principal axes of the valve. This technique was chosen for ease of implementation, speed, and accuracy. The first step of the alignment procedure is to correct for translational and rotational motion by aligning the centroids of segmented valve images according to their principal axes. The second step involves a rotational correction for each leg of the outlet strut using a linear cross-correlation of data sampled along a specified are about the centroid. This technique has been successfully applied to a preliminary set (10 patients) of digital radiographic data (8-16 sequential frames). This technique was determined accurate to within 2 pixels at a spatial resolution of 139 /spl mu/m/pixel.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"30 1","pages":"619-622"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An automated temporal alignment technique for the translational and rotational correction of digital radiographic images of Bjork-Shiley heart valves\",\"authors\":\"E. Çesmeli, K. Powell, N. Greenberg, J. Cornhill\",\"doi\":\"10.1109/CIC.1993.378326\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An accurate technique for the temporal registration of digital radiographic valve images is an integral process in the objective quantification of single leg separation (SLS) in Bjork-Shiley Convexo Concave heart valves. The authors have developed a fully automated technique for the translational and rotational correction of sequential valve images based on the principal axes of the valve. This technique was chosen for ease of implementation, speed, and accuracy. The first step of the alignment procedure is to correct for translational and rotational motion by aligning the centroids of segmented valve images according to their principal axes. The second step involves a rotational correction for each leg of the outlet strut using a linear cross-correlation of data sampled along a specified are about the centroid. This technique has been successfully applied to a preliminary set (10 patients) of digital radiographic data (8-16 sequential frames). This technique was determined accurate to within 2 pixels at a spatial resolution of 139 /spl mu/m/pixel.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"30 1\",\"pages\":\"619-622\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378326\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378326","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

数字放射线图像时间配准技术是Bjork-Shiley凸凹型心脏瓣膜单腿分离(SLS)客观量化的重要组成部分。作者开发了一种全自动技术,用于基于阀门主轴的顺序阀门图像的平移和旋转校正。选择这种技术是因为易于实现、速度快和准确。校准程序的第一步是通过根据阀的主轴对齐分段图像的质心来校正平移和旋转运动。第二步涉及使用沿指定质心方向采样的数据的线性互相关对出口支柱的每个分支进行旋转校正。该技术已成功应用于初步组(10例患者)的数字放射学数据(8-16序列帧)。该技术在139 /spl mu/m/pixel的空间分辨率下精确到2像素以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An automated temporal alignment technique for the translational and rotational correction of digital radiographic images of Bjork-Shiley heart valves
An accurate technique for the temporal registration of digital radiographic valve images is an integral process in the objective quantification of single leg separation (SLS) in Bjork-Shiley Convexo Concave heart valves. The authors have developed a fully automated technique for the translational and rotational correction of sequential valve images based on the principal axes of the valve. This technique was chosen for ease of implementation, speed, and accuracy. The first step of the alignment procedure is to correct for translational and rotational motion by aligning the centroids of segmented valve images according to their principal axes. The second step involves a rotational correction for each leg of the outlet strut using a linear cross-correlation of data sampled along a specified are about the centroid. This technique has been successfully applied to a preliminary set (10 patients) of digital radiographic data (8-16 sequential frames). This technique was determined accurate to within 2 pixels at a spatial resolution of 139 /spl mu/m/pixel.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials Computers: the heart of screening Signal averaging enhancement by jitter deconvolution Numerical simulation of the flow in model skeletal muscle ventricles Transmembrane potential changes during stimulation in a bidomain model of the myocardium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1