Xin Bao , Jingbo Liu , Hui Tan , Shutao Li , Fei Wang
{"title":"浅埋地下结构在P波、SV波和瑞利波作用下的地震反应对比分析","authors":"Xin Bao , Jingbo Liu , Hui Tan , Shutao Li , Fei Wang","doi":"10.1016/j.eqrea.2022.100179","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, A time-domain seismic response analysis method and a calculation model of the underground structure that can realize the input of seismic P, SV and Rayleigh waves are established, based on the viscoelastic artificial boundary elements and the boundary substructure method for seismic wave input. After verifying the calculation accuracy, a comparative study on seismic response of a shallow-buried, double-deck, double-span subway station structure under incident P, SV and Rayleigh waves is conducted. The research results show that there are certain differences in the cross-sectional internal force distribution characteristics of underground structures under different types of seismic waves. The research results show that there are certain differences in the internal force distribution characteristics of underground structures under different types of seismic waves. At the bottom of the side wall, the top and bottom of the center pillar of the underground structure, the section bending moments of the underground structure under the incidences of SV wave and Rayleigh wave are relatively close, and are significantly larger than the calculation result under the incidence of P wave. At the center of the side wall and the top floor of the structure, the peak value of the cross-sectional internal force under the incident Rayleigh wave is larger than the calculation result under SV wave. In addition, the floor of the underground structure under Rayleigh waves vibrates in both the horizontal and vertical directions, and the magnification effect in the vertical direction is more significant. Considering that the current seismic research of underground structures mainly considers the effect of body waves such as the shear waves, sufficient attention should be paid to the incidence of Rayleigh waves in the future seismic design of shallow underground structures.</p></div>","PeriodicalId":100384,"journal":{"name":"Earthquake Research Advances","volume":"2 4","pages":"Article 100179"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772467022000707/pdfft?md5=b6c3242c26d954e8d85d3ef98f0c333e&pid=1-s2.0-S2772467022000707-main.pdf","citationCount":"1","resultStr":"{\"title\":\"A comparative analysis of seismic response of shallow buried underground structure under incident P, SV and Rayleigh waves\",\"authors\":\"Xin Bao , Jingbo Liu , Hui Tan , Shutao Li , Fei Wang\",\"doi\":\"10.1016/j.eqrea.2022.100179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, A time-domain seismic response analysis method and a calculation model of the underground structure that can realize the input of seismic P, SV and Rayleigh waves are established, based on the viscoelastic artificial boundary elements and the boundary substructure method for seismic wave input. After verifying the calculation accuracy, a comparative study on seismic response of a shallow-buried, double-deck, double-span subway station structure under incident P, SV and Rayleigh waves is conducted. The research results show that there are certain differences in the cross-sectional internal force distribution characteristics of underground structures under different types of seismic waves. The research results show that there are certain differences in the internal force distribution characteristics of underground structures under different types of seismic waves. At the bottom of the side wall, the top and bottom of the center pillar of the underground structure, the section bending moments of the underground structure under the incidences of SV wave and Rayleigh wave are relatively close, and are significantly larger than the calculation result under the incidence of P wave. At the center of the side wall and the top floor of the structure, the peak value of the cross-sectional internal force under the incident Rayleigh wave is larger than the calculation result under SV wave. In addition, the floor of the underground structure under Rayleigh waves vibrates in both the horizontal and vertical directions, and the magnification effect in the vertical direction is more significant. Considering that the current seismic research of underground structures mainly considers the effect of body waves such as the shear waves, sufficient attention should be paid to the incidence of Rayleigh waves in the future seismic design of shallow underground structures.</p></div>\",\"PeriodicalId\":100384,\"journal\":{\"name\":\"Earthquake Research Advances\",\"volume\":\"2 4\",\"pages\":\"Article 100179\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2772467022000707/pdfft?md5=b6c3242c26d954e8d85d3ef98f0c333e&pid=1-s2.0-S2772467022000707-main.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Earthquake Research Advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772467022000707\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earthquake Research Advances","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772467022000707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparative analysis of seismic response of shallow buried underground structure under incident P, SV and Rayleigh waves
In this study, A time-domain seismic response analysis method and a calculation model of the underground structure that can realize the input of seismic P, SV and Rayleigh waves are established, based on the viscoelastic artificial boundary elements and the boundary substructure method for seismic wave input. After verifying the calculation accuracy, a comparative study on seismic response of a shallow-buried, double-deck, double-span subway station structure under incident P, SV and Rayleigh waves is conducted. The research results show that there are certain differences in the cross-sectional internal force distribution characteristics of underground structures under different types of seismic waves. The research results show that there are certain differences in the internal force distribution characteristics of underground structures under different types of seismic waves. At the bottom of the side wall, the top and bottom of the center pillar of the underground structure, the section bending moments of the underground structure under the incidences of SV wave and Rayleigh wave are relatively close, and are significantly larger than the calculation result under the incidence of P wave. At the center of the side wall and the top floor of the structure, the peak value of the cross-sectional internal force under the incident Rayleigh wave is larger than the calculation result under SV wave. In addition, the floor of the underground structure under Rayleigh waves vibrates in both the horizontal and vertical directions, and the magnification effect in the vertical direction is more significant. Considering that the current seismic research of underground structures mainly considers the effect of body waves such as the shear waves, sufficient attention should be paid to the incidence of Rayleigh waves in the future seismic design of shallow underground structures.