{"title":"质子治疗用常导定标固定场交变梯度加速器","authors":"J. Garland, R. Appleby, H. Owen, S. Tygier","doi":"10.1103/PHYSREVSTAB.18.094701","DOIUrl":null,"url":null,"abstract":"In this paper we present a new lattice design for a 30–350 MeV scaling fixed-field alternating gradient accelerator for proton therapy and tomography—NORMA (NOrmal-conducting Racetrack Medical Accelerator). The energy range allows the realization of proton computed tomography and utilizes normal conducting magnets in both a conventional circular ring option and a novel racetrack configuration, both designed using advanced optimization algorithms we have developed in PyZgoubi. Both configurations consist of ten focusing-defocusing-focusing triplet cells and operate in the second stability region of Hills equation. The ring configuration has a circumference of 60 m, a peak magnetic field seen by the beam of <1.6 T, a maximum horizontal orbit excursion of 44 cm and a dynamic aperture of 68 mm mrad— determined using a novel dynamic aperture (DA) calculation technique. The racetrack alternative is realized by adding magnet-free drift space in between cells at two opposing points in the ring, to facilitate injection and extraction. Our racetrack design has a total magnet-free straight lengths of 4.9 m, a circumference of 71 m, a peak magnetic field seen by the beam of <1.74 T, a maximum horizontal orbit excursion of 50 cm and a DA of 58 mm mrad. A transverse magnet misalignment model is also presented for the ring and racetrack configurations where the DA remains above 40 mm mrad for randomly misaligned error distributions with a standard deviation up to 100 μm.","PeriodicalId":20072,"journal":{"name":"Physical Review Special Topics-accelerators and Beams","volume":"92 1","pages":"094701"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Normal-conducting scaling fixed field alternating gradient accelerator for proton therapy\",\"authors\":\"J. Garland, R. Appleby, H. Owen, S. Tygier\",\"doi\":\"10.1103/PHYSREVSTAB.18.094701\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we present a new lattice design for a 30–350 MeV scaling fixed-field alternating gradient accelerator for proton therapy and tomography—NORMA (NOrmal-conducting Racetrack Medical Accelerator). The energy range allows the realization of proton computed tomography and utilizes normal conducting magnets in both a conventional circular ring option and a novel racetrack configuration, both designed using advanced optimization algorithms we have developed in PyZgoubi. Both configurations consist of ten focusing-defocusing-focusing triplet cells and operate in the second stability region of Hills equation. The ring configuration has a circumference of 60 m, a peak magnetic field seen by the beam of <1.6 T, a maximum horizontal orbit excursion of 44 cm and a dynamic aperture of 68 mm mrad— determined using a novel dynamic aperture (DA) calculation technique. The racetrack alternative is realized by adding magnet-free drift space in between cells at two opposing points in the ring, to facilitate injection and extraction. Our racetrack design has a total magnet-free straight lengths of 4.9 m, a circumference of 71 m, a peak magnetic field seen by the beam of <1.74 T, a maximum horizontal orbit excursion of 50 cm and a DA of 58 mm mrad. A transverse magnet misalignment model is also presented for the ring and racetrack configurations where the DA remains above 40 mm mrad for randomly misaligned error distributions with a standard deviation up to 100 μm.\",\"PeriodicalId\":20072,\"journal\":{\"name\":\"Physical Review Special Topics-accelerators and Beams\",\"volume\":\"92 1\",\"pages\":\"094701\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical Review Special Topics-accelerators and Beams\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1103/PHYSREVSTAB.18.094701\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Review Special Topics-accelerators and Beams","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1103/PHYSREVSTAB.18.094701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
摘要
本文提出了一种用于质子治疗和层析成像的30-350 MeV尺度固定场交变梯度加速器的新晶格设计- norma(正常传导赛道医学加速器)。该能量范围允许实现质子计算机断层扫描,并在传统的环形选项和新颖的赛道配置中使用正常导电磁铁,两者都使用我们在PyZgoubi开发的先进优化算法设计。这两种结构都由十个聚焦-散焦-聚焦三重单元组成,并在希尔斯方程的第二稳定区工作。环形结构的周长为60 m,波束的峰值磁场<1.6 T,最大水平轨道偏移44 cm,动态孔径为68 mm,采用一种新的动态孔径(DA)计算技术确定。赛道替代方案是通过在环中两个相对点的细胞之间增加无磁漂移空间来实现的,以方便注射和提取。我们设计的赛道总无磁直线长度为4.9 m,周长为71 m,波束看到的峰值磁场<1.74 T,最大水平轨道偏移50 cm, DA为58 mm mrad。此外,本文还建立了环形和赛道结构的横向磁体失调模型,其中DA保持在40 mm mrad以上,随机失调误差分布的标准偏差可达100 μm。
Normal-conducting scaling fixed field alternating gradient accelerator for proton therapy
In this paper we present a new lattice design for a 30–350 MeV scaling fixed-field alternating gradient accelerator for proton therapy and tomography—NORMA (NOrmal-conducting Racetrack Medical Accelerator). The energy range allows the realization of proton computed tomography and utilizes normal conducting magnets in both a conventional circular ring option and a novel racetrack configuration, both designed using advanced optimization algorithms we have developed in PyZgoubi. Both configurations consist of ten focusing-defocusing-focusing triplet cells and operate in the second stability region of Hills equation. The ring configuration has a circumference of 60 m, a peak magnetic field seen by the beam of <1.6 T, a maximum horizontal orbit excursion of 44 cm and a dynamic aperture of 68 mm mrad— determined using a novel dynamic aperture (DA) calculation technique. The racetrack alternative is realized by adding magnet-free drift space in between cells at two opposing points in the ring, to facilitate injection and extraction. Our racetrack design has a total magnet-free straight lengths of 4.9 m, a circumference of 71 m, a peak magnetic field seen by the beam of <1.74 T, a maximum horizontal orbit excursion of 50 cm and a DA of 58 mm mrad. A transverse magnet misalignment model is also presented for the ring and racetrack configurations where the DA remains above 40 mm mrad for randomly misaligned error distributions with a standard deviation up to 100 μm.
期刊介绍:
Physical Review Special Topics - Accelerators and Beams (PRST-AB), is a peer reviewed, purely electronic journal, distributed without charge to readers and funded by contributions from national laboratories. It covers the full range of accelerator science and technology: subsystem and component technologies, beam dynamics; accelerator applications; and design, operation, and improvement of accelerators used in science and industry. This includes accelerators for high-energy and nuclear physics, synchrotron radiation production, spallation neutron sources, medical therapy, and intense beam applications.