A. Maheshwari, Ravi Gupta, Debmalya Saha, S. Naqvi, H. Minhas, M. Geelani
{"title":"主动脉瓣置换术中处理小主动脉根的Konno方法12例体会","authors":"A. Maheshwari, Ravi Gupta, Debmalya Saha, S. Naqvi, H. Minhas, M. Geelani","doi":"10.4236/wjcs.2020.102004","DOIUrl":null,"url":null,"abstract":"Background: Small aortic annulus during aortic valve replacement can lead to implanting a smaller sized valve compared to the body surface area thereby causing patient prosthesis mismatch. Various aortic root enlargement techniques have been described depending on anterior or posterior approach. Konno procedure uses anterior approach for aortic root enlargement. In this study, we reviewed results of Konno procedure done from 2011 to 2019 by a single surgeon. Methods: 12 adult patients who underwent aortic valve replacement along with Konno procedure for small aortic root by a single surgeon at a single center between 2011 and 2019 were reviewed. Echocardiographic and demographic data and post-operative data were obtained from medical records. Symptomatic profile was assessed as per New York Heart Association Classification. Intraoperative findings and post-operative period findings were noted. Follow up symptom profile was assessed for these patients. Results: 12 patients underwent Konno procedure between 2011 and 2019 for small aortic root along with valve replacement. The main indication for surgery was aortic stenosis with small aortic annulus, with or without involvement of the mitral valve. Preoperatively, 3 patients had NYHA class II and 9 patients had NYHA class III symptoms. Mean age at operation was 26.42 years, minimum age 10 years, and maximum age 39 years. 3 were females and 9 were males. Mean bypass time was 106.4 minutes and aortic cross clamp time was 80.67 minutes. Mechanical aortic valves were implanted in all patients. Mean post-operative blood loss was 134.2 ml and duration of ventilation before extubation was 14.5 hours. Mean duration of intensive care unit (ICU) stay was 2.83 days and hospital stay was 9.1 days. Mean gradient in the post-operative period was 10.75 mm Hg. There was no mortality in these 12 patients and no reoperation was needed in the follow up period. Follow up in the outpatient department suggested all patients had NYHA class I symptoms and anticoagulation with warfarin adjusted to prothrombin time— International normalised ratio. Conclusion: Konno procedure is effective for managing small aortic root as bigger outflow orifice area through the larger valve prosthesis improves ventricular outflow and hence, improves the outcomes.","PeriodicalId":23646,"journal":{"name":"World Journal of Cardiovascular Surgery","volume":"123 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Konno Procedure for Managing Small Aortic Root during Aortic Valve Replacement Surgery: An Experience of 12 Cases\",\"authors\":\"A. Maheshwari, Ravi Gupta, Debmalya Saha, S. Naqvi, H. Minhas, M. Geelani\",\"doi\":\"10.4236/wjcs.2020.102004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Small aortic annulus during aortic valve replacement can lead to implanting a smaller sized valve compared to the body surface area thereby causing patient prosthesis mismatch. Various aortic root enlargement techniques have been described depending on anterior or posterior approach. Konno procedure uses anterior approach for aortic root enlargement. In this study, we reviewed results of Konno procedure done from 2011 to 2019 by a single surgeon. Methods: 12 adult patients who underwent aortic valve replacement along with Konno procedure for small aortic root by a single surgeon at a single center between 2011 and 2019 were reviewed. Echocardiographic and demographic data and post-operative data were obtained from medical records. Symptomatic profile was assessed as per New York Heart Association Classification. Intraoperative findings and post-operative period findings were noted. Follow up symptom profile was assessed for these patients. Results: 12 patients underwent Konno procedure between 2011 and 2019 for small aortic root along with valve replacement. The main indication for surgery was aortic stenosis with small aortic annulus, with or without involvement of the mitral valve. Preoperatively, 3 patients had NYHA class II and 9 patients had NYHA class III symptoms. Mean age at operation was 26.42 years, minimum age 10 years, and maximum age 39 years. 3 were females and 9 were males. Mean bypass time was 106.4 minutes and aortic cross clamp time was 80.67 minutes. Mechanical aortic valves were implanted in all patients. Mean post-operative blood loss was 134.2 ml and duration of ventilation before extubation was 14.5 hours. Mean duration of intensive care unit (ICU) stay was 2.83 days and hospital stay was 9.1 days. Mean gradient in the post-operative period was 10.75 mm Hg. There was no mortality in these 12 patients and no reoperation was needed in the follow up period. Follow up in the outpatient department suggested all patients had NYHA class I symptoms and anticoagulation with warfarin adjusted to prothrombin time— International normalised ratio. Conclusion: Konno procedure is effective for managing small aortic root as bigger outflow orifice area through the larger valve prosthesis improves ventricular outflow and hence, improves the outcomes.\",\"PeriodicalId\":23646,\"journal\":{\"name\":\"World Journal of Cardiovascular Surgery\",\"volume\":\"123 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/wjcs.2020.102004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Cardiovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/wjcs.2020.102004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
背景:主动脉瓣置换术中主动脉环小可能导致植入的瓣膜尺寸小于体表面积,从而导致患者假体不匹配。根据前路或后路的不同,已经描述了各种主动脉根部扩大技术。Konno手术采用前路手术治疗主动脉根部肿大。在这项研究中,我们回顾了2011年至2019年由一名外科医生进行的Konno手术的结果。方法:回顾了2011年至2019年在单一中心由同一名外科医生接受主动脉瓣置换术和Konno手术治疗小主动脉根的12例成年患者。超声心动图和人口统计资料及术后资料均来自医疗记录。根据纽约心脏协会分类对症状进行评估。记录术中及术后表现。对这些患者的随访症状进行评估。结果:2011年至2019年期间,12名患者接受了Konno手术治疗小主动脉根并进行了瓣膜置换术。手术的主要指征是主动脉狭窄伴小主动脉环,伴或不伴二尖瓣受累。术前3例出现NYHA II级症状,9例出现NYHA III级症状。平均手术年龄26.42岁,最小年龄10岁,最大年龄39岁。女性3例,男性9例。平均旁路时间106.4分钟,主动脉交叉夹持时间80.67分钟。所有患者均植入机械主动脉瓣。术后平均失血量134.2 ml,拔管前通气时间14.5小时。重症监护病房(ICU)平均住院时间2.83天,住院时间9.1天。术后平均梯度为10.75 mm Hg, 12例患者无死亡,随访期间无再次手术。门诊随访提示所有患者均有NYHA I级症状,并使用华法林调整至凝血酶原时间-国际正常化比率抗凝。结论:Konno手术是治疗小主动脉根的有效方法,通过较大的瓣膜假体扩大流出口面积,改善心室流出,从而改善预后。
Konno Procedure for Managing Small Aortic Root during Aortic Valve Replacement Surgery: An Experience of 12 Cases
Background: Small aortic annulus during aortic valve replacement can lead to implanting a smaller sized valve compared to the body surface area thereby causing patient prosthesis mismatch. Various aortic root enlargement techniques have been described depending on anterior or posterior approach. Konno procedure uses anterior approach for aortic root enlargement. In this study, we reviewed results of Konno procedure done from 2011 to 2019 by a single surgeon. Methods: 12 adult patients who underwent aortic valve replacement along with Konno procedure for small aortic root by a single surgeon at a single center between 2011 and 2019 were reviewed. Echocardiographic and demographic data and post-operative data were obtained from medical records. Symptomatic profile was assessed as per New York Heart Association Classification. Intraoperative findings and post-operative period findings were noted. Follow up symptom profile was assessed for these patients. Results: 12 patients underwent Konno procedure between 2011 and 2019 for small aortic root along with valve replacement. The main indication for surgery was aortic stenosis with small aortic annulus, with or without involvement of the mitral valve. Preoperatively, 3 patients had NYHA class II and 9 patients had NYHA class III symptoms. Mean age at operation was 26.42 years, minimum age 10 years, and maximum age 39 years. 3 were females and 9 were males. Mean bypass time was 106.4 minutes and aortic cross clamp time was 80.67 minutes. Mechanical aortic valves were implanted in all patients. Mean post-operative blood loss was 134.2 ml and duration of ventilation before extubation was 14.5 hours. Mean duration of intensive care unit (ICU) stay was 2.83 days and hospital stay was 9.1 days. Mean gradient in the post-operative period was 10.75 mm Hg. There was no mortality in these 12 patients and no reoperation was needed in the follow up period. Follow up in the outpatient department suggested all patients had NYHA class I symptoms and anticoagulation with warfarin adjusted to prothrombin time— International normalised ratio. Conclusion: Konno procedure is effective for managing small aortic root as bigger outflow orifice area through the larger valve prosthesis improves ventricular outflow and hence, improves the outcomes.