次氯酸钠和氯乙胺对XP-Endo精加工仪动态抗循环疲劳性能的影响

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Giornale Italiano di Endodonzia Pub Date : 2021-02-08 DOI:10.32067/GIE.2021.35.01.06
Elson Lopes Medeiros Junior, A. Limoeiro, Alexandra Tanomaro, Adriana de Jesus Soares, Gabriel Fillipe Centini Campos, Nelson T. Mohara, Wayne Martins, Danilo de Luca Campos, M. Frozoni
{"title":"次氯酸钠和氯乙胺对XP-Endo精加工仪动态抗循环疲劳性能的影响","authors":"Elson Lopes Medeiros Junior, A. Limoeiro, Alexandra Tanomaro, Adriana de Jesus Soares, Gabriel Fillipe Centini Campos, Nelson T. Mohara, Wayne Martins, Danilo de Luca Campos, M. Frozoni","doi":"10.32067/GIE.2021.35.01.06","DOIUrl":null,"url":null,"abstract":"Aim: This study evaluated the cyclic fatigue resistance of XP-Endo Finisher (XPF), associated with two different irrigation solutions: sodium hypochlorite 6% (NaOCl) or chlorhexidine digluconate gel 2% (CHX) in a dynamic model. The null hypothesis tested was that there was no statistically significant difference. \nMethodology: 30 new files were divided into three groups (n=10) based on the irrigation solution used. Group 1: XPF using CHX as an irrigation solution; Group 2: XPF using NaOCl as an irrigation solution; Group 3 (control group): XPF using lubricating oil (LO). The artificial canal was manufactured measuring 1.5 mm wide, 20 mm long, and 3.5 mm deep with a straight cervical segment measuring 14.29 mm. A curved apical segment 4.71 mm with 3 mm radius and 90° of curvature and an ending with straight apical portion measuring 1 mm long. Resistance to cyclic fatigue was determined by recording time to fracture, and the file surface was examined under scanning electron microscopy. \nResults: Data were tabulated and subjected to statistical analysis of variance. Student-Newman-Keuls test for multiple comparisons, with a significance level of 5%. The average time took for file fracture was 306.7 seconds for 2% chlorhexidine and 67,6 for 6% sodium hypochlorite. 2% CHX was significantly different from the NaOCl and LO groups (P< .001). \nConclusions: XPF presented the best results of fracture time and the number of cycles to fracture when used along with 2% chlorhexidine in canals with severe apical curvature, and there was no statistical difference in fragment size.","PeriodicalId":42221,"journal":{"name":"Giornale Italiano di Endodonzia","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2021-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Influence of sodium hypochlorite and chlorexidine on the dynamic cyclic fatigue resistance of XP-Endo Finisher instruments\",\"authors\":\"Elson Lopes Medeiros Junior, A. Limoeiro, Alexandra Tanomaro, Adriana de Jesus Soares, Gabriel Fillipe Centini Campos, Nelson T. Mohara, Wayne Martins, Danilo de Luca Campos, M. Frozoni\",\"doi\":\"10.32067/GIE.2021.35.01.06\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: This study evaluated the cyclic fatigue resistance of XP-Endo Finisher (XPF), associated with two different irrigation solutions: sodium hypochlorite 6% (NaOCl) or chlorhexidine digluconate gel 2% (CHX) in a dynamic model. The null hypothesis tested was that there was no statistically significant difference. \\nMethodology: 30 new files were divided into three groups (n=10) based on the irrigation solution used. Group 1: XPF using CHX as an irrigation solution; Group 2: XPF using NaOCl as an irrigation solution; Group 3 (control group): XPF using lubricating oil (LO). The artificial canal was manufactured measuring 1.5 mm wide, 20 mm long, and 3.5 mm deep with a straight cervical segment measuring 14.29 mm. A curved apical segment 4.71 mm with 3 mm radius and 90° of curvature and an ending with straight apical portion measuring 1 mm long. Resistance to cyclic fatigue was determined by recording time to fracture, and the file surface was examined under scanning electron microscopy. \\nResults: Data were tabulated and subjected to statistical analysis of variance. Student-Newman-Keuls test for multiple comparisons, with a significance level of 5%. The average time took for file fracture was 306.7 seconds for 2% chlorhexidine and 67,6 for 6% sodium hypochlorite. 2% CHX was significantly different from the NaOCl and LO groups (P< .001). \\nConclusions: XPF presented the best results of fracture time and the number of cycles to fracture when used along with 2% chlorhexidine in canals with severe apical curvature, and there was no statistical difference in fragment size.\",\"PeriodicalId\":42221,\"journal\":{\"name\":\"Giornale Italiano di Endodonzia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2021-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale Italiano di Endodonzia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32067/GIE.2021.35.01.06\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale Italiano di Endodonzia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32067/GIE.2021.35.01.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

摘要

目的:本研究在动态模型中评估了XPF - endo Finisher (XPF)与两种不同灌溉溶液(次氯酸钠6% (NaOCl)或二光酸氯己定凝胶2% (CHX))的循环疲劳抗性。检验的零假设是没有统计学上的显著差异。方法:将30个新锉按冲洗液的不同分为3组(n=10)。第一组:以CHX为灌洗液的XPF;第二组:以NaOCl为灌洗液的XPF;第三组(对照组):XPF使用润滑油(LO)。人工管宽1.5 mm,长20 mm,深3.5 mm,颈段直长14.29 mm。一个弯曲的根尖部分,直径4.71毫米,半径3mm,曲率90°,根尖部分直,长度1mm。通过记录断裂时间来测定锉的抗循环疲劳性能,并在扫描电镜下对锉表面进行了观察。结果:将数据制成表格,进行方差统计分析。Student-Newman-Keuls多重比较检验,显著性水平为5%。2%氯己定和6%次氯酸钠的平均骨折时间分别为306.7秒和67.6秒。2% CHX与NaOCl、LO组比较差异有统计学意义(P< 0.001)。结论:XPF与2%氯己定联合应用于严重根尖弯曲管的骨折时间和骨折循环次数最佳,且碎片大小无统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of sodium hypochlorite and chlorexidine on the dynamic cyclic fatigue resistance of XP-Endo Finisher instruments
Aim: This study evaluated the cyclic fatigue resistance of XP-Endo Finisher (XPF), associated with two different irrigation solutions: sodium hypochlorite 6% (NaOCl) or chlorhexidine digluconate gel 2% (CHX) in a dynamic model. The null hypothesis tested was that there was no statistically significant difference. Methodology: 30 new files were divided into three groups (n=10) based on the irrigation solution used. Group 1: XPF using CHX as an irrigation solution; Group 2: XPF using NaOCl as an irrigation solution; Group 3 (control group): XPF using lubricating oil (LO). The artificial canal was manufactured measuring 1.5 mm wide, 20 mm long, and 3.5 mm deep with a straight cervical segment measuring 14.29 mm. A curved apical segment 4.71 mm with 3 mm radius and 90° of curvature and an ending with straight apical portion measuring 1 mm long. Resistance to cyclic fatigue was determined by recording time to fracture, and the file surface was examined under scanning electron microscopy. Results: Data were tabulated and subjected to statistical analysis of variance. Student-Newman-Keuls test for multiple comparisons, with a significance level of 5%. The average time took for file fracture was 306.7 seconds for 2% chlorhexidine and 67,6 for 6% sodium hypochlorite. 2% CHX was significantly different from the NaOCl and LO groups (P< .001). Conclusions: XPF presented the best results of fracture time and the number of cycles to fracture when used along with 2% chlorhexidine in canals with severe apical curvature, and there was no statistical difference in fragment size.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Giornale Italiano di Endodonzia
Giornale Italiano di Endodonzia DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
25.00%
发文量
0
审稿时长
24 weeks
期刊介绍: The Giornale Italiano di Endodonzia was founded in 1987 and is the official journal of the Italian Society of Endodontics (SIE). It is a peer-reviewed journal publishing original articles on clinical research and/or clinical methodology, case reports related to Endodontics. The Journal evaluates also contributes in restorative dentistry, dental traumatology, experimental pathophysiology, pharmacology and microbiology dealing with Endodontics.
期刊最新文献
Comparative efficacy of Depotphoresis and diode laser for reduction of microbial load and postoperative pain, and healing of periapical lesions: a randomized clinical trial Endodontics: clinical protocols on scientific basis Anatomical proximity of upper teeth and local factors associated with the thickness of the maxillary sinus membrane: a retrospective study A contemporary approach to treat necrotic immature teeth using different bioceramic materials Endodontic guides and ultrasonic tips for management of calcifications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1