使用碳化钨钎剂后对搪瓷表面进行评估,以去除残留的粘合剂

Marijana Arapović Savić, Adriana Arbutina, Mirjana Umićević Davidović, V. Mirjanić, Irena Kuzmanović Radman
{"title":"使用碳化钨钎剂后对搪瓷表面进行评估,以去除残留的粘合剂","authors":"Marijana Arapović Savić, Adriana Arbutina, Mirjana Umićević Davidović, V. Mirjanić, Irena Kuzmanović Radman","doi":"10.7251/comen1802137a","DOIUrl":null,"url":null,"abstract":"Enamel damage often occurs in a process of adhesive removal after the completion of therapy with fixed orthodontic appliances. The aim of this study was to evaluate the enamel surface after applying a 12-fluted round tungsten carbide bur for adhesive removal at different speeds of dental micro motor after debonding brackets. Material and method: On 40 human premolars, extracted for orthodontic purposes, metal brackets were bonded with composite material. After removing the brackets, the sample was divided into two groups: group A - 20 teeth from which the rest of the composite material was removed with a round tungsten carbide bur at 8,000 rotations per minute and group B - 20 teeth from which the rest of adhesive was removed with a round tungsten carbide bur at 32,000 rotations per minute. For each sample, four images were made under different magnifications by scanning electron microscopy, and the damage estimation was performed using the Enamel damage index (EDI) and Surface roughness index (SRI). Results: The most common EDI score on the overall level was 3 (62.5%), while the most commonly represented SRI score was 2 (52.5%). There was no statistically significant difference in the average values of the EDI index (t (38) = -.96, p> .05) and in the average SRI index values (t (38) = -. 89, p> .05) between two tooth examined groups. Conclusion: Enamel damage was found after applying a round tungsten carbide bur at 8,000 and 32,000 rpm. The number of rotations per minute did not affect the size of enamel damage.","PeriodicalId":10617,"journal":{"name":"Contemporary Materials","volume":"78 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ASSESSMENT OF ENAMEL SURFACE AFTER APPLICATION OF TUNGSTEN CARBIDE BUR FOR RESIDUAL ADHESIVE REMOVAL\",\"authors\":\"Marijana Arapović Savić, Adriana Arbutina, Mirjana Umićević Davidović, V. Mirjanić, Irena Kuzmanović Radman\",\"doi\":\"10.7251/comen1802137a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Enamel damage often occurs in a process of adhesive removal after the completion of therapy with fixed orthodontic appliances. The aim of this study was to evaluate the enamel surface after applying a 12-fluted round tungsten carbide bur for adhesive removal at different speeds of dental micro motor after debonding brackets. Material and method: On 40 human premolars, extracted for orthodontic purposes, metal brackets were bonded with composite material. After removing the brackets, the sample was divided into two groups: group A - 20 teeth from which the rest of the composite material was removed with a round tungsten carbide bur at 8,000 rotations per minute and group B - 20 teeth from which the rest of adhesive was removed with a round tungsten carbide bur at 32,000 rotations per minute. For each sample, four images were made under different magnifications by scanning electron microscopy, and the damage estimation was performed using the Enamel damage index (EDI) and Surface roughness index (SRI). Results: The most common EDI score on the overall level was 3 (62.5%), while the most commonly represented SRI score was 2 (52.5%). There was no statistically significant difference in the average values of the EDI index (t (38) = -.96, p> .05) and in the average SRI index values (t (38) = -. 89, p> .05) between two tooth examined groups. Conclusion: Enamel damage was found after applying a round tungsten carbide bur at 8,000 and 32,000 rpm. The number of rotations per minute did not affect the size of enamel damage.\",\"PeriodicalId\":10617,\"journal\":{\"name\":\"Contemporary Materials\",\"volume\":\"78 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contemporary Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7251/comen1802137a\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7251/comen1802137a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

牙釉质损伤通常发生在固定矫治器治疗完成后的黏合剂去除过程中。本研究的目的是评估牙槽脱粘后,在牙微马达的不同转速下,使用12槽碳化钨圆钎去除牙釉质表面的效果。材料与方法:对40颗拔除用于正畸的人类前磨牙,采用复合材料粘结金属托槽。取出托槽后,将样品分为两组:A组20颗牙,用圆形碳化钨钎以每分钟8000转的速度去除剩余的复合材料;B组20颗牙,用圆形碳化钨钎以每分钟32000转的速度去除剩余的粘接剂。对每个样品在不同的放大倍数下进行扫描电镜成像,利用釉质损伤指数(EDI)和表面粗糙度指数(SRI)进行损伤估计。结果:总体水平上最常见的EDI得分为3(62.5%),而最常见的SRI得分为2(52.5%)。两组间EDI指数平均值差异无统计学意义(t(38) = -)。96, p> 0.05),平均SRI指数值(t(38) = -。89, p> 0.05)。结论:在8000转/分和32000转/分的转速下使用碳化钨圆刺后发现牙釉质损伤。每分钟旋转数对牙釉质损伤大小没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ASSESSMENT OF ENAMEL SURFACE AFTER APPLICATION OF TUNGSTEN CARBIDE BUR FOR RESIDUAL ADHESIVE REMOVAL
Enamel damage often occurs in a process of adhesive removal after the completion of therapy with fixed orthodontic appliances. The aim of this study was to evaluate the enamel surface after applying a 12-fluted round tungsten carbide bur for adhesive removal at different speeds of dental micro motor after debonding brackets. Material and method: On 40 human premolars, extracted for orthodontic purposes, metal brackets were bonded with composite material. After removing the brackets, the sample was divided into two groups: group A - 20 teeth from which the rest of the composite material was removed with a round tungsten carbide bur at 8,000 rotations per minute and group B - 20 teeth from which the rest of adhesive was removed with a round tungsten carbide bur at 32,000 rotations per minute. For each sample, four images were made under different magnifications by scanning electron microscopy, and the damage estimation was performed using the Enamel damage index (EDI) and Surface roughness index (SRI). Results: The most common EDI score on the overall level was 3 (62.5%), while the most commonly represented SRI score was 2 (52.5%). There was no statistically significant difference in the average values of the EDI index (t (38) = -.96, p> .05) and in the average SRI index values (t (38) = -. 89, p> .05) between two tooth examined groups. Conclusion: Enamel damage was found after applying a round tungsten carbide bur at 8,000 and 32,000 rpm. The number of rotations per minute did not affect the size of enamel damage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
LABORATORY TESTING OF UNSTIMULATED AND STIMULATED SALIVA BUFFERING CAPACITY IN PATIENT AND CONTROL GROUPS AFTER TITRATION WITH HCl AND NaOH NEURAL NETWORKS FOR SOLVING HUXLEY’S EQUATION USE OF 3D-BIOPRINTING IN TISSUE ENGINEERING SCAFFOLD PRODUCTION DETERMINATION OF IRON CONTENT IN NATURAL MINERAL WATER: COMPARISON OF ICP-OES AND SPECTROPHOTOMETRIC METHOD INFLUENCE OF GEOLOGICAL PARAMETERS ON THE INDOOR RADON CONCENTRATION IN THE CITY OF TREBINJE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1