{"title":"不锈钢室平衡透析,环孢素游离血浆组分的测定","authors":"F. Callejón, J. A. Duran, J. A. Abadín, A. Sánchez","doi":"10.1211/146080800128735494","DOIUrl":null,"url":null,"abstract":"The aim of this study was to demonstrate the sealing of a prototype stainless steel dialysis chamber and the reproducibility of the results after using the chamber to measure the free plasma fraction of cyclosporin. \n \n \n \nThe chamber comprised two compartments (A and B), in each of which was a hemisphere of approximately 1-mL capacity. To demonstrate sealing, equilibrium dialysis was carried out simultaneously in 10 chambers, but in which the semipermeable membrane separating the two compartments was substituted by an impermeable membrane. Chamber sealing was checked by the absence of liquid in the compartment B at the end of dialysis. To test reproducibility, equilibrium dialysis was carried out in 10 chambers containing cyclosporin. The mean value for the free plasma fraction of cyclosporin was 0.65%, giving a coefficient of variation within the acceptable limit of error. \n \n \n \nThe use of this stainless steel chamber is recommended when large numbers of dialyses of cyclosporin must be carried out frequently.","PeriodicalId":19946,"journal":{"name":"Pharmacy and Pharmacology Communications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Equilibrium Dialysis in a Stainless Steel Chamber, Measurement of the Free Plasma Fraction of Cyclosporin\",\"authors\":\"F. Callejón, J. A. Duran, J. A. Abadín, A. Sánchez\",\"doi\":\"10.1211/146080800128735494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to demonstrate the sealing of a prototype stainless steel dialysis chamber and the reproducibility of the results after using the chamber to measure the free plasma fraction of cyclosporin. \\n \\n \\n \\nThe chamber comprised two compartments (A and B), in each of which was a hemisphere of approximately 1-mL capacity. To demonstrate sealing, equilibrium dialysis was carried out simultaneously in 10 chambers, but in which the semipermeable membrane separating the two compartments was substituted by an impermeable membrane. Chamber sealing was checked by the absence of liquid in the compartment B at the end of dialysis. To test reproducibility, equilibrium dialysis was carried out in 10 chambers containing cyclosporin. The mean value for the free plasma fraction of cyclosporin was 0.65%, giving a coefficient of variation within the acceptable limit of error. \\n \\n \\n \\nThe use of this stainless steel chamber is recommended when large numbers of dialyses of cyclosporin must be carried out frequently.\",\"PeriodicalId\":19946,\"journal\":{\"name\":\"Pharmacy and Pharmacology Communications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmacy and Pharmacology Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1211/146080800128735494\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmacy and Pharmacology Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1211/146080800128735494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究的目的是证明一个原型不锈钢透析室的密封性和使用该室测量环孢素游离血浆部分后结果的可重复性。腔室由两个隔间(A和B)组成,每个隔间中都有一个容量约为1毫升的半球。为了证明密封,平衡透析在10个腔室中同时进行,但其中分隔两个腔室的半透膜被不透膜取代。通过透析结束时B室中没有液体来检查腔室密封。为了检验重现性,在10个含环孢素的腔室中进行平衡透析。血浆游离环孢素含量平均值为0.65%,变异系数在可接受的误差范围内。当必须经常进行大量环孢素透析时,建议使用这种不锈钢腔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Equilibrium Dialysis in a Stainless Steel Chamber, Measurement of the Free Plasma Fraction of Cyclosporin
The aim of this study was to demonstrate the sealing of a prototype stainless steel dialysis chamber and the reproducibility of the results after using the chamber to measure the free plasma fraction of cyclosporin. The chamber comprised two compartments (A and B), in each of which was a hemisphere of approximately 1-mL capacity. To demonstrate sealing, equilibrium dialysis was carried out simultaneously in 10 chambers, but in which the semipermeable membrane separating the two compartments was substituted by an impermeable membrane. Chamber sealing was checked by the absence of liquid in the compartment B at the end of dialysis. To test reproducibility, equilibrium dialysis was carried out in 10 chambers containing cyclosporin. The mean value for the free plasma fraction of cyclosporin was 0.65%, giving a coefficient of variation within the acceptable limit of error. The use of this stainless steel chamber is recommended when large numbers of dialyses of cyclosporin must be carried out frequently.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
HPLC‐NMR Spectroscopy Extraction of Peptidase Substrates by the Isolated Perfused Rat Lung Effect of Liposomes on Permeation of Diclofenac Through Cadaver Skin: In‐vivo Evaluation Using Animal Models Regulation of Hyperthyroidism by Rauwolfia serpentina Root Extract in Mice Preparation and Evaluation of Liposomal Flucinolone Acetonide Gel for Intradermal Delivery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1