高精度电阻点焊硬膜下电极急性皮质电成像应用

J. Krishnan, R. Rethnagireeshwar, B. Benjamin, N. V. Panicker, A. R. Biju Ramu
{"title":"高精度电阻点焊硬膜下电极急性皮质电成像应用","authors":"J. Krishnan, R. Rethnagireeshwar, B. Benjamin, N. V. Panicker, A. R. Biju Ramu","doi":"10.1109/ICPCSI.2017.8391916","DOIUrl":null,"url":null,"abstract":"Electrocorticography (ECoG), or intracranial electroencephalography (iEEG), is a type of electrophysiological monitoring in which an array of subdural electrodes are used to record signals in ECoG. Subdural electrodes are made by welding Platinum/Stainless steel discs to Platinum/Iridium wire. Precise welding of electrode parts are essential for ensuring biocompatibility and proper impedance to curb with noise conditions which is essential for data acquisition. This paper proposes a design and implementation of a capacitor discharge type impulse current generation for resistance spot welding of subdural elctrode parts. Weld strength test like tensile test and vibration test of subdural electrode parts made of stainless steel were conducted to validate the process invitro.","PeriodicalId":6589,"journal":{"name":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","volume":"1 1","pages":"1284-1287"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High precision resistance spot welding with subdural electrodes for acute electrocorticography applications\",\"authors\":\"J. Krishnan, R. Rethnagireeshwar, B. Benjamin, N. V. Panicker, A. R. Biju Ramu\",\"doi\":\"10.1109/ICPCSI.2017.8391916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrocorticography (ECoG), or intracranial electroencephalography (iEEG), is a type of electrophysiological monitoring in which an array of subdural electrodes are used to record signals in ECoG. Subdural electrodes are made by welding Platinum/Stainless steel discs to Platinum/Iridium wire. Precise welding of electrode parts are essential for ensuring biocompatibility and proper impedance to curb with noise conditions which is essential for data acquisition. This paper proposes a design and implementation of a capacitor discharge type impulse current generation for resistance spot welding of subdural elctrode parts. Weld strength test like tensile test and vibration test of subdural electrode parts made of stainless steel were conducted to validate the process invitro.\",\"PeriodicalId\":6589,\"journal\":{\"name\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"volume\":\"1 1\",\"pages\":\"1284-1287\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCSI.2017.8391916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCSI.2017.8391916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

脑皮质电图(ECoG)或颅内脑电图(iEEG)是一种电生理监测,其中硬脑膜下电极阵列用于记录ECoG中的信号。硬膜下电极由铂/不锈钢片焊接到铂/铱丝制成。电极部件的精确焊接是保证生物相容性和抑制噪声条件的必要条件,而噪声条件是数据采集的必要条件。本文提出了一种用于硬膜下电极部件电阻点焊的电容放电式脉冲电流发生器的设计与实现。对不锈钢硬膜下电极件进行了拉伸试验和振动试验等焊接强度试验,对工艺进行了体外验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High precision resistance spot welding with subdural electrodes for acute electrocorticography applications
Electrocorticography (ECoG), or intracranial electroencephalography (iEEG), is a type of electrophysiological monitoring in which an array of subdural electrodes are used to record signals in ECoG. Subdural electrodes are made by welding Platinum/Stainless steel discs to Platinum/Iridium wire. Precise welding of electrode parts are essential for ensuring biocompatibility and proper impedance to curb with noise conditions which is essential for data acquisition. This paper proposes a design and implementation of a capacitor discharge type impulse current generation for resistance spot welding of subdural elctrode parts. Weld strength test like tensile test and vibration test of subdural electrode parts made of stainless steel were conducted to validate the process invitro.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A hybrid approach for pansharpening using Hilbert vibration decomposition Comparative analysis of multi carrier PWM eleven level inverter with two modulation waves PWM based multilevel feed induction drive using single phase to three phase converter TCR designing to minimize the voltage fluctuation within 5% of three phase arc furnace A TLBO algorithm based optimal load scheduling of generators for power system network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1