迈向高品质的X-59音波测量

IF 1.3 4区 医学 Q3 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY Noise & Health Pub Date : 2023-05-25 DOI:10.3397/nc_2023_0144
Mark C. Anderson, K. Gee, J. Durrant, A. Loubeau
{"title":"迈向高品质的X-59音波测量","authors":"Mark C. Anderson, K. Gee, J. Durrant, A. Loubeau","doi":"10.3397/nc_2023_0144","DOIUrl":null,"url":null,"abstract":"Brigham Young University has been studying questions related to NASA X-59 community noise testing. A summary of the key findings and recommendations to date are presented. Among these are weather-resistant ground microphone setups that reduce wind noise, methods for treating the problem\n of ambient noise contamination on sonic boom metrics and spectra, and the turbulence-induced variability seen over relatively small-aperture arrays. Also discussed are recommendations for data post-processing, e.g., employing a digital pole-shifting filter and zero-padding to improve the fidelity\n and smoothness of low-frequency spectral data. Finally, the relative merits of various sonic boom metrics are considered. Although Perceived Level has been the most widely-used metric, it is relatively sensitive to ambient noise contamination and turbulence-induced variability. [Work supported\n by NASA Langley Research Center through the National Institute of Aerospace.]","PeriodicalId":19195,"journal":{"name":"Noise & Health","volume":"10 1","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Towards high-quality X-59 sonic thump measurements\",\"authors\":\"Mark C. Anderson, K. Gee, J. Durrant, A. Loubeau\",\"doi\":\"10.3397/nc_2023_0144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Brigham Young University has been studying questions related to NASA X-59 community noise testing. A summary of the key findings and recommendations to date are presented. Among these are weather-resistant ground microphone setups that reduce wind noise, methods for treating the problem\\n of ambient noise contamination on sonic boom metrics and spectra, and the turbulence-induced variability seen over relatively small-aperture arrays. Also discussed are recommendations for data post-processing, e.g., employing a digital pole-shifting filter and zero-padding to improve the fidelity\\n and smoothness of low-frequency spectral data. Finally, the relative merits of various sonic boom metrics are considered. Although Perceived Level has been the most widely-used metric, it is relatively sensitive to ambient noise contamination and turbulence-induced variability. [Work supported\\n by NASA Langley Research Center through the National Institute of Aerospace.]\",\"PeriodicalId\":19195,\"journal\":{\"name\":\"Noise & Health\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Noise & Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3397/nc_2023_0144\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Noise & Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3397/nc_2023_0144","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

杨百翰大学一直在研究与NASA X-59社区噪音测试相关的问题。本文概述了迄今为止的主要调查结果和建议。其中包括减少风噪声的耐天气地面麦克风装置,处理音爆指标和谱上的环境噪声污染问题的方法,以及在相对小孔径阵列上看到的湍流引起的变异性。还讨论了数据后处理的建议,例如,采用数字移极滤波器和零填充来提高低频频谱数据的保真度和平滑度。最后,讨论了各种音爆指标的相对优点。虽然感知水平是最广泛使用的度量,但它对环境噪声污染和湍流引起的变化相对敏感。[工作由NASA兰利研究中心通过国家航空航天研究所支持。]
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards high-quality X-59 sonic thump measurements
Brigham Young University has been studying questions related to NASA X-59 community noise testing. A summary of the key findings and recommendations to date are presented. Among these are weather-resistant ground microphone setups that reduce wind noise, methods for treating the problem of ambient noise contamination on sonic boom metrics and spectra, and the turbulence-induced variability seen over relatively small-aperture arrays. Also discussed are recommendations for data post-processing, e.g., employing a digital pole-shifting filter and zero-padding to improve the fidelity and smoothness of low-frequency spectral data. Finally, the relative merits of various sonic boom metrics are considered. Although Perceived Level has been the most widely-used metric, it is relatively sensitive to ambient noise contamination and turbulence-induced variability. [Work supported by NASA Langley Research Center through the National Institute of Aerospace.]
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Noise & Health
Noise & Health AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
CiteScore
2.10
自引率
14.30%
发文量
27
审稿时长
6-12 weeks
期刊介绍: Noise and Health is the only International Journal devoted to research on all aspects of noise and its effects on human health. An inter-disciplinary journal for all professions concerned with auditory and non-auditory effects of occupational, environmental, and leisure noise. It aims to provide a forum for presentation of novel research material on a broad range of topics associated with noise pollution, its control and its detrimental effects on hearing and health. It will cover issues from basic experimental science through clinical evaluation and management, technical aspects of noise reduction systems and solutions to environmental issues relating to social and public health policy.
期刊最新文献
A Simplified Version of the Chinese Tinnitus Disorder Scale and its Psychometric Characteristics. Analysis of Therapeutic Options for Noise-Induced Hearing Loss: Retroauricular Injection of Methylprednisolone Sodium Succinate Combined with Hyperbaric Oxygenation. Application of Mozart's Sonata for Two Pianos in D Major in Children with Epilepsy and Effect of Acoustic Quality on Epileptic Discharges. Application of Music Therapy in Improving Sleep Quality and Psychological Health of Pregnant Women with Hypertension: A Retrospective Study. Application of Music Therapy in Improving the Sleep Quality and Mental Health of Nurses with Circadian Rhythm Sleep Disorders Caused by Work Shifts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1