Irene Poza-Casado, Alberto Meiss, M. Padilla-Marcos, Jesús Feijó-Muñoz
{"title":"西班牙住宅建筑空气渗透的气密性及能量影响","authors":"Irene Poza-Casado, Alberto Meiss, M. Padilla-Marcos, Jesús Feijó-Muñoz","doi":"10.1080/14733315.2020.1777029","DOIUrl":null,"url":null,"abstract":"Abstract Addressing the airtightness of the building envelope is key to achieve thermal comfort, good performance ofventilation systems and to avoid excessive energy consumption. Previous studies have estimated an energy impact of infiltration on the heating demand between 2 and 20 kW h/(m2 y) in regions with temperate climates. In Spain, this issue has not yet been addressed in depth. This study aims to assess the energy impact of uncontrolled airflows through the envelope in residential buildings in Spain. For this purpose, airtightness results of more than 400 blower door tests have been analysed. Multi-family and single-family dwellings built in several periods and located in nine regions with different climate characteristics have been studied. Infiltration was found to have an energy impact in the range 2.43–19.07 kW h/(m2 y) for the heating demand, whereas it is not so significant regarding the cooling demand. The obtained results show great potential for energy saving in the country.","PeriodicalId":55613,"journal":{"name":"International Journal of Ventilation","volume":"21 1","pages":"258 - 264"},"PeriodicalIF":1.1000,"publicationDate":"2020-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Airtightness and energy impact of air infiltration in residential buildings in Spain\",\"authors\":\"Irene Poza-Casado, Alberto Meiss, M. Padilla-Marcos, Jesús Feijó-Muñoz\",\"doi\":\"10.1080/14733315.2020.1777029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Addressing the airtightness of the building envelope is key to achieve thermal comfort, good performance ofventilation systems and to avoid excessive energy consumption. Previous studies have estimated an energy impact of infiltration on the heating demand between 2 and 20 kW h/(m2 y) in regions with temperate climates. In Spain, this issue has not yet been addressed in depth. This study aims to assess the energy impact of uncontrolled airflows through the envelope in residential buildings in Spain. For this purpose, airtightness results of more than 400 blower door tests have been analysed. Multi-family and single-family dwellings built in several periods and located in nine regions with different climate characteristics have been studied. Infiltration was found to have an energy impact in the range 2.43–19.07 kW h/(m2 y) for the heating demand, whereas it is not so significant regarding the cooling demand. The obtained results show great potential for energy saving in the country.\",\"PeriodicalId\":55613,\"journal\":{\"name\":\"International Journal of Ventilation\",\"volume\":\"21 1\",\"pages\":\"258 - 264\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2020-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Ventilation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/14733315.2020.1777029\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Ventilation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/14733315.2020.1777029","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Airtightness and energy impact of air infiltration in residential buildings in Spain
Abstract Addressing the airtightness of the building envelope is key to achieve thermal comfort, good performance ofventilation systems and to avoid excessive energy consumption. Previous studies have estimated an energy impact of infiltration on the heating demand between 2 and 20 kW h/(m2 y) in regions with temperate climates. In Spain, this issue has not yet been addressed in depth. This study aims to assess the energy impact of uncontrolled airflows through the envelope in residential buildings in Spain. For this purpose, airtightness results of more than 400 blower door tests have been analysed. Multi-family and single-family dwellings built in several periods and located in nine regions with different climate characteristics have been studied. Infiltration was found to have an energy impact in the range 2.43–19.07 kW h/(m2 y) for the heating demand, whereas it is not so significant regarding the cooling demand. The obtained results show great potential for energy saving in the country.
期刊介绍:
This is a peer reviewed journal aimed at providing the latest information on research and application.
Topics include:
• New ideas concerned with the development or application of ventilation;
• Validated case studies demonstrating the performance of ventilation strategies;
• Information on needs and solutions for specific building types including: offices, dwellings, schools, hospitals, parking garages, urban buildings and recreational buildings etc;
• Developments in numerical methods;
• Measurement techniques;
• Related issues in which the impact of ventilation plays an important role (e.g. the interaction of ventilation with air quality, health and comfort);
• Energy issues related to ventilation (e.g. low energy systems, ventilation heating and cooling loss);
• Driving forces (weather data, fan performance etc).