{"title":"皮上锁定钢板治疗小儿开放性胫骨骨折","authors":"V. N. Radhakrishna, V. Madhuri","doi":"10.1097/BPB.0000000000000425","DOIUrl":null,"url":null,"abstract":"We evaluated the novel application of supracutaneous locked plates in pediatric open tibia fractures. Pediatric open tibia fractures stabilized with a locked supracutaneous plate from January 2011 to December 2014 were reviewed. Twenty-eight children, mean age 8.9 years, with 29 open tibia fractures were included. Nine of these children who had metaphyseal or metadiaphyseal fractures did not require joint spanning. The mean follow-up duration was 13.5 months. The mean time to uneventful union was 11.46 weeks, with no unacceptable malunion. Supracutaneous locked plates showed early union and no refractures. They could favorably replace tubular external fixators in stabilizing pediatric open tibia fractures.","PeriodicalId":16709,"journal":{"name":"Journal of Pediatric Orthopaedics B","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Management of pediatric open tibia fractures with supracutaneous locked plates\",\"authors\":\"V. N. Radhakrishna, V. Madhuri\",\"doi\":\"10.1097/BPB.0000000000000425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We evaluated the novel application of supracutaneous locked plates in pediatric open tibia fractures. Pediatric open tibia fractures stabilized with a locked supracutaneous plate from January 2011 to December 2014 were reviewed. Twenty-eight children, mean age 8.9 years, with 29 open tibia fractures were included. Nine of these children who had metaphyseal or metadiaphyseal fractures did not require joint spanning. The mean follow-up duration was 13.5 months. The mean time to uneventful union was 11.46 weeks, with no unacceptable malunion. Supracutaneous locked plates showed early union and no refractures. They could favorably replace tubular external fixators in stabilizing pediatric open tibia fractures.\",\"PeriodicalId\":16709,\"journal\":{\"name\":\"Journal of Pediatric Orthopaedics B\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pediatric Orthopaedics B\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/BPB.0000000000000425\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics B","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000000425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

我们评估了皮上锁定钢板在小儿开放性胫骨骨折中的新应用。本文回顾了2011年1月至2014年12月期间儿童开放性胫骨骨折用锁定皮上钢板固定的情况。28名儿童,平均年龄8.9岁,29例开放性胫骨骨折。其中9例发生干骺端或干骺端骨折的患儿不需要关节跨越。平均随访时间为13.5个月。平均愈合时间为11.46周,无不可接受的畸形愈合。皮上锁定钢板早期愈合,无复发。它们可以很好地替代管状外固定架稳定儿童开放性胫骨骨折。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Management of pediatric open tibia fractures with supracutaneous locked plates
We evaluated the novel application of supracutaneous locked plates in pediatric open tibia fractures. Pediatric open tibia fractures stabilized with a locked supracutaneous plate from January 2011 to December 2014 were reviewed. Twenty-eight children, mean age 8.9 years, with 29 open tibia fractures were included. Nine of these children who had metaphyseal or metadiaphyseal fractures did not require joint spanning. The mean follow-up duration was 13.5 months. The mean time to uneventful union was 11.46 weeks, with no unacceptable malunion. Supracutaneous locked plates showed early union and no refractures. They could favorably replace tubular external fixators in stabilizing pediatric open tibia fractures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of risk factors for nonunion in pediatric lateral column lengthening’ by Torrez et al. A comparison of cone beam computed tomography, standard computed tomography, and plain radiographs in the evaluation of medial epicondyle humerus fractures Letter to the editor, concerning Cimen et al.: ‘Percutaneous release for trigger thumb in children under local anesthesia’ Referral patterns to a pediatric orthopedic clinic: pediatric orthopedic surgeons are primary care musculoskeletal medicine physicians Reliability and validity of Vancouver Scar Scale and Withey score after syndactyly release
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1