石墨炉原子吸收光谱法和混合基体改性法测定甲状腺功能减退患者的Cr、Se、Ge和V

Halah Hamid Hammadi
{"title":"石墨炉原子吸收光谱法和混合基体改性法测定甲状腺功能减退患者的Cr、Se、Ge和V","authors":"Halah Hamid Hammadi","doi":"10.32947/ajps.v23i1.986","DOIUrl":null,"url":null,"abstract":"A simple, accurate and rapid method was developed for routine determination of trace elements in blood serum. The method based on the direct determination for Cr, Se, Ge, and V in hypothyroidism patients before therapy. By using atomic absorption spectrometry with graphite surface coated and uncoated pyrolysis GF-AAS, and a mixture of palladium nitrate and magnesium nitrate as the matrix modifier, with deuterium background correction and no sample pretreatment except dilution was necessary. This permitted direct determination hence the risk of sample contamination was reduced. Further, the use of graphite surface-coated GF-AAS decreased the ashing and atomization temperatures of Cr, Ge, and V to values that were lesser than the corresponding values obtained using uncoated pyrolysis GF-AAS, by 100°C; in case of Se, the atomization temperature decreased to a value that was 200°C lesser than that obtained using uncoated pyrolysis GF-AAS. \nA mixture of (3µL) palladium nitrate, and (2µL) magnesium nitrate was successfully applied to improve the sensitivity, reproducibility, recovery, limit of detection and the accuracy of the measurements. The correlation coefficients of the calibration curves of Cr, Se, Ge, and V were found to be (0.9999, 0.9999, 0.9995 and 0.9999) respectively, the relative standard deviation of the measurements for Cr, Se, Ge and V were (0.027, 0.075, 0.054 and 0.068) respectively. The statistical analysis of the acquired data showed acceptable accuracy. The analyses thus performed indicated that the levels of serum trace elements Cr, Se, Ge, and V in hypothyroidism patients were lower than those in the control group.","PeriodicalId":7406,"journal":{"name":"Al Mustansiriyah Journal of Pharmaceutical Sciences","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Cr, Se, Ge, and V in Hypothyroidism Patients by Using Graphite Furnace Atomic Absorption Spectrometry and mixture matrix modification\",\"authors\":\"Halah Hamid Hammadi\",\"doi\":\"10.32947/ajps.v23i1.986\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, accurate and rapid method was developed for routine determination of trace elements in blood serum. The method based on the direct determination for Cr, Se, Ge, and V in hypothyroidism patients before therapy. By using atomic absorption spectrometry with graphite surface coated and uncoated pyrolysis GF-AAS, and a mixture of palladium nitrate and magnesium nitrate as the matrix modifier, with deuterium background correction and no sample pretreatment except dilution was necessary. This permitted direct determination hence the risk of sample contamination was reduced. Further, the use of graphite surface-coated GF-AAS decreased the ashing and atomization temperatures of Cr, Ge, and V to values that were lesser than the corresponding values obtained using uncoated pyrolysis GF-AAS, by 100°C; in case of Se, the atomization temperature decreased to a value that was 200°C lesser than that obtained using uncoated pyrolysis GF-AAS. \\nA mixture of (3µL) palladium nitrate, and (2µL) magnesium nitrate was successfully applied to improve the sensitivity, reproducibility, recovery, limit of detection and the accuracy of the measurements. The correlation coefficients of the calibration curves of Cr, Se, Ge, and V were found to be (0.9999, 0.9999, 0.9995 and 0.9999) respectively, the relative standard deviation of the measurements for Cr, Se, Ge and V were (0.027, 0.075, 0.054 and 0.068) respectively. The statistical analysis of the acquired data showed acceptable accuracy. The analyses thus performed indicated that the levels of serum trace elements Cr, Se, Ge, and V in hypothyroidism patients were lower than those in the control group.\",\"PeriodicalId\":7406,\"journal\":{\"name\":\"Al Mustansiriyah Journal of Pharmaceutical Sciences\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al Mustansiriyah Journal of Pharmaceutical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32947/ajps.v23i1.986\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al Mustansiriyah Journal of Pharmaceutical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32947/ajps.v23i1.986","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种简单、准确、快速的血清微量元素常规测定方法。该方法基于治疗前甲状腺功能减退患者的Cr、Se、Ge、V的直接测定。采用石墨表面包覆和未包覆热解GF-AAS原子吸收光谱法,以硝酸钯和硝酸镁的混合物为基体改性剂,进行氘背景校正,除稀释外无需样品前处理。这允许直接测定,因此降低了样品污染的风险。此外,使用石墨表面包覆的GF-AAS使Cr、Ge和V的灰化和雾化温度比使用未包覆的热解GF-AAS的相应温度低100℃;在Se的情况下,雾化温度下降到比未包覆热解GF-AAS低200℃。(3µL)硝酸钯和(2µL)硝酸镁的混合物被成功地应用于提高灵敏度、重现性、回收率、检出限和测量的准确性。结果表明,Cr、Se、Ge和V的校准曲线相关系数分别为(0.9999、0.9999、0.9995和0.9999),Cr、Se、Ge和V的相对标准偏差分别为(0.027、0.075、0.054和0.068)。对采集数据的统计分析显示出可接受的准确性。结果表明,甲减患者血清微量元素Cr、Se、Ge、V的含量低于对照组。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of Cr, Se, Ge, and V in Hypothyroidism Patients by Using Graphite Furnace Atomic Absorption Spectrometry and mixture matrix modification
A simple, accurate and rapid method was developed for routine determination of trace elements in blood serum. The method based on the direct determination for Cr, Se, Ge, and V in hypothyroidism patients before therapy. By using atomic absorption spectrometry with graphite surface coated and uncoated pyrolysis GF-AAS, and a mixture of palladium nitrate and magnesium nitrate as the matrix modifier, with deuterium background correction and no sample pretreatment except dilution was necessary. This permitted direct determination hence the risk of sample contamination was reduced. Further, the use of graphite surface-coated GF-AAS decreased the ashing and atomization temperatures of Cr, Ge, and V to values that were lesser than the corresponding values obtained using uncoated pyrolysis GF-AAS, by 100°C; in case of Se, the atomization temperature decreased to a value that was 200°C lesser than that obtained using uncoated pyrolysis GF-AAS. A mixture of (3µL) palladium nitrate, and (2µL) magnesium nitrate was successfully applied to improve the sensitivity, reproducibility, recovery, limit of detection and the accuracy of the measurements. The correlation coefficients of the calibration curves of Cr, Se, Ge, and V were found to be (0.9999, 0.9999, 0.9995 and 0.9999) respectively, the relative standard deviation of the measurements for Cr, Se, Ge and V were (0.027, 0.075, 0.054 and 0.068) respectively. The statistical analysis of the acquired data showed acceptable accuracy. The analyses thus performed indicated that the levels of serum trace elements Cr, Se, Ge, and V in hypothyroidism patients were lower than those in the control group.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect Of Different Variables On The Formulation Of Sodium Alginate Beads Evaluating Serum Calprotectin and Serum Oncostatin M Levels as Diagnostic Markers in Crohn's Disease and Ulcerative Colitis Iraqi Patients. Research Effects Of Topical Petroleum Ether and Ethyl Acetate Fractions from Grape Seed Extract on Imiquimod-Induced Psoriasis Like Skin Inflammation in Mice Evaluation of C-Reactive Protein, Interleukin-6, and Neutrophil-Lymphocyte Ratio as Inflammatory Markers in Patients with Chronic Bronchitis Taking Oral Prednisolone in Maysan City Population Analysis of Favipiravir Adverse Drug Reactions during COVID-19 Pandemic: A Retrospective Study Based on Iraqi Pharmacovigilance Center Database
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1