{"title":"一个真实的LED灯闪烁案例研究","authors":"J. Drapela, R. Langella, A. Testa, J. Grappe","doi":"10.1109/ICHQP.2018.8378906","DOIUrl":null,"url":null,"abstract":"This paper shows the results of a real life case-study which demonstrates also that there is a need for new Flickermeters able to cope with new lamps' technologies different from standard incandescent, in particular with LED lamps. The case-study refers to a LED lamp that was visibly flickering even if measurements taken onsite with a standard PQ instrument reported neither THD nor Pst issues. Numerical tests using a new Flickermeter proposed by some of the authors and laboratory experiments by means of an objective light Flickermeter have demonstrated the reasons of this singular case.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"20 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A real life light flicker case-study with LED lamps\",\"authors\":\"J. Drapela, R. Langella, A. Testa, J. Grappe\",\"doi\":\"10.1109/ICHQP.2018.8378906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper shows the results of a real life case-study which demonstrates also that there is a need for new Flickermeters able to cope with new lamps' technologies different from standard incandescent, in particular with LED lamps. The case-study refers to a LED lamp that was visibly flickering even if measurements taken onsite with a standard PQ instrument reported neither THD nor Pst issues. Numerical tests using a new Flickermeter proposed by some of the authors and laboratory experiments by means of an objective light Flickermeter have demonstrated the reasons of this singular case.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"20 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378906\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A real life light flicker case-study with LED lamps
This paper shows the results of a real life case-study which demonstrates also that there is a need for new Flickermeters able to cope with new lamps' technologies different from standard incandescent, in particular with LED lamps. The case-study refers to a LED lamp that was visibly flickering even if measurements taken onsite with a standard PQ instrument reported neither THD nor Pst issues. Numerical tests using a new Flickermeter proposed by some of the authors and laboratory experiments by means of an objective light Flickermeter have demonstrated the reasons of this singular case.