{"title":"阳极生产和质量的关键问题,以避免阳极性能问题","authors":"B. Sadler, Барри А. Сэдлер","doi":"10.17516/1999-494x-2015-8-5-546-568","DOIUrl":null,"url":null,"abstract":"There are a number of key anode quality parameters that must be kept stable and capable in order for the anodes to perform at the standard required by modern cells. If the anode production steps that influence these parameters are not managed well, the resulting sub-standard anodes can impact on the performance of the cell. The link between these properties and anode/cell performance are outlined in this paper Normal 0 false false false RU X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:\"Обычная таблица\"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:\"\"; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:\"Calibri\",\"sans-serif\"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:\"Times New Roman\"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}","PeriodicalId":11548,"journal":{"name":"Engineering & Technologies","volume":"14 1","pages":"546-568"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Critical issues in anode production and quality to avoid anode performance problems\",\"authors\":\"B. Sadler, Барри А. Сэдлер\",\"doi\":\"10.17516/1999-494x-2015-8-5-546-568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are a number of key anode quality parameters that must be kept stable and capable in order for the anodes to perform at the standard required by modern cells. If the anode production steps that influence these parameters are not managed well, the resulting sub-standard anodes can impact on the performance of the cell. The link between these properties and anode/cell performance are outlined in this paper Normal 0 false false false RU X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:\\\"Обычная таблица\\\"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:\\\"\\\"; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:\\\"Calibri\\\",\\\"sans-serif\\\"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:\\\"Times New Roman\\\"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}\",\"PeriodicalId\":11548,\"journal\":{\"name\":\"Engineering & Technologies\",\"volume\":\"14 1\",\"pages\":\"546-568\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering & Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17516/1999-494x-2015-8-5-546-568\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering & Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17516/1999-494x-2015-8-5-546-568","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Critical issues in anode production and quality to avoid anode performance problems
There are a number of key anode quality parameters that must be kept stable and capable in order for the anodes to perform at the standard required by modern cells. If the anode production steps that influence these parameters are not managed well, the resulting sub-standard anodes can impact on the performance of the cell. The link between these properties and anode/cell performance are outlined in this paper Normal 0 false false false RU X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Обычная таблица"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}