啁啾编码脉冲激励超声弹性成像

Hui Peng, D. Liu
{"title":"啁啾编码脉冲激励超声弹性成像","authors":"Hui Peng, D. Liu","doi":"10.1109/ICBBE.2010.5516328","DOIUrl":null,"url":null,"abstract":"We first designed two chirp-coded excitation/ compression schemes which were applied to ultrasound elasticity imaging in simulation method using Field II. The simulation results demonstrate that in low echo-signal-to-noise ratio (eSNR) conditions, the performance of chirp-coded pulse for elasticity imaging is much better than the conventional short pulse, and indicate that elastographic signal-to-noise ratio (SNRe) of strain images for chirp-coded pulse is a function of attenuation, electronic noise, applied strain, pulse length, compression filter and depth. Comparing the effects of two chirp-coded excitation/compression schemes on strain imaging, we demonstrate that under the conditions of low eSNR, the first scheme, the combination of chirp excitation pulse with window and matched compression filter, is suitable to be used in low attenuation situations, and the second scheme, the combination of chirp excitation pulse without window and mismatched compression filter, is fit to be used in high attenuation situations. Finally, we applied the second chirp-coded scheme to a real-time freehand ultrasound strain imaging system and phantom experimental results are consistent with that in simulation method.","PeriodicalId":6396,"journal":{"name":"2010 4th International Conference on Bioinformatics and Biomedical Engineering","volume":"10 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Chirp-Coded Pulse Excitation for Ultrasound Elasticity Imaging\",\"authors\":\"Hui Peng, D. Liu\",\"doi\":\"10.1109/ICBBE.2010.5516328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We first designed two chirp-coded excitation/ compression schemes which were applied to ultrasound elasticity imaging in simulation method using Field II. The simulation results demonstrate that in low echo-signal-to-noise ratio (eSNR) conditions, the performance of chirp-coded pulse for elasticity imaging is much better than the conventional short pulse, and indicate that elastographic signal-to-noise ratio (SNRe) of strain images for chirp-coded pulse is a function of attenuation, electronic noise, applied strain, pulse length, compression filter and depth. Comparing the effects of two chirp-coded excitation/compression schemes on strain imaging, we demonstrate that under the conditions of low eSNR, the first scheme, the combination of chirp excitation pulse with window and matched compression filter, is suitable to be used in low attenuation situations, and the second scheme, the combination of chirp excitation pulse without window and mismatched compression filter, is fit to be used in high attenuation situations. Finally, we applied the second chirp-coded scheme to a real-time freehand ultrasound strain imaging system and phantom experimental results are consistent with that in simulation method.\",\"PeriodicalId\":6396,\"journal\":{\"name\":\"2010 4th International Conference on Bioinformatics and Biomedical Engineering\",\"volume\":\"10 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Conference on Bioinformatics and Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBBE.2010.5516328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Conference on Bioinformatics and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBBE.2010.5516328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

首先设计了两种啁啾编码的激励/压缩方案,并将其应用于超声弹性成像的仿真方法。仿真结果表明,在低回波信噪比(eSNR)条件下,啁啾编码脉冲弹性成像的性能远优于传统短脉冲,啁啾编码脉冲应变图像的弹性信噪比(SNRe)是衰减、电子噪声、外加应变、脉冲长度、压缩滤波器和深度的函数。比较了两种啁啾编码激励/压缩方案对应变成像的影响,证明了在低eSNR条件下,第一种方案,即带窗口的啁啾激励脉冲与匹配的压缩滤波器相结合,适用于低衰减情况,第二种方案,即无窗口的啁啾激励脉冲与不匹配的压缩滤波器相结合,适用于高衰减情况。最后,将第二种啁啾编码方案应用于实时徒手超声应变成像系统,仿真实验结果与仿真方法一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Chirp-Coded Pulse Excitation for Ultrasound Elasticity Imaging
We first designed two chirp-coded excitation/ compression schemes which were applied to ultrasound elasticity imaging in simulation method using Field II. The simulation results demonstrate that in low echo-signal-to-noise ratio (eSNR) conditions, the performance of chirp-coded pulse for elasticity imaging is much better than the conventional short pulse, and indicate that elastographic signal-to-noise ratio (SNRe) of strain images for chirp-coded pulse is a function of attenuation, electronic noise, applied strain, pulse length, compression filter and depth. Comparing the effects of two chirp-coded excitation/compression schemes on strain imaging, we demonstrate that under the conditions of low eSNR, the first scheme, the combination of chirp excitation pulse with window and matched compression filter, is suitable to be used in low attenuation situations, and the second scheme, the combination of chirp excitation pulse without window and mismatched compression filter, is fit to be used in high attenuation situations. Finally, we applied the second chirp-coded scheme to a real-time freehand ultrasound strain imaging system and phantom experimental results are consistent with that in simulation method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterization of Codon Usage Bias in the Newly Identified DEV UL53 Gene Indoor Air Quality Assessment in an Art Gallery with an HVAC System Multi-Method Measurement on Mercury Concentration in Plants Optimization of Nutrition Condition for Biodegradation of Diesel Oil Using Response Surface Methodology Application of SWAT in Non-Point Source Pollution of Upper Xiliaohe Basin, China
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1