{"title":"地平面对距离依赖性电力线泄漏电场的影响","authors":"Y. Watanabe, M. Tokuda","doi":"10.1109/ISEMC.2005.1513673","DOIUrl":null,"url":null,"abstract":"In this paper, we focused attention on the system that used the MHz band in a power line communication, and calculated the influence of electric condition of ground plane to distance dependence and electric field distribution of leaked electric field by method of moments. As a result, we understood the standard ground attenuated leaked electric field to distance as not 20 dB/dec but 40 dB/dec. And we understood the almost uniform attenuation in the standard ground independency of direction from the electric field distribution.","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"27 1","pages":"1008-1013 Vol. 3"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Influence of ground plane to distance dependence leaked electric field from power line\",\"authors\":\"Y. Watanabe, M. Tokuda\",\"doi\":\"10.1109/ISEMC.2005.1513673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we focused attention on the system that used the MHz band in a power line communication, and calculated the influence of electric condition of ground plane to distance dependence and electric field distribution of leaked electric field by method of moments. As a result, we understood the standard ground attenuated leaked electric field to distance as not 20 dB/dec but 40 dB/dec. And we understood the almost uniform attenuation in the standard ground independency of direction from the electric field distribution.\",\"PeriodicalId\":6459,\"journal\":{\"name\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"volume\":\"27 1\",\"pages\":\"1008-1013 Vol. 3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2005.1513673\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of ground plane to distance dependence leaked electric field from power line
In this paper, we focused attention on the system that used the MHz band in a power line communication, and calculated the influence of electric condition of ground plane to distance dependence and electric field distribution of leaked electric field by method of moments. As a result, we understood the standard ground attenuated leaked electric field to distance as not 20 dB/dec but 40 dB/dec. And we understood the almost uniform attenuation in the standard ground independency of direction from the electric field distribution.